A novel method for passing cerebrospinal fluid shunt tubing: a proof of principle study

R. Shane Tubbs, Dylan Goodrich, Isaiah Tubbs, Marios Loukas, Aaron Cohen-Gadol

Research output: Contribution to journalArticle

Abstract

Materials and methods: On 10 cadaver sides and when placed in the supine position, small skin incisions were made at the clavicle and ipsilateral subcostal region, and magnets were used to pass standard shunt tubing between the two incisions.

Introduction: Few innovations in the method of tunneling shunt tubing for cerebrospinal fluid (CSF) shunt diversion have been made since this treatment of hydrocephalus was first developed. Therefore, this feasibility study was performed with the hope of identifying an improved technique that could potentially carry fewer complications.

Results: Nickel-plated magnets were less effective in pulling the shunt tubing below the skin compared with ceramic magnets. Of these, magnets with pull strengths of 150–200 lbs were the most effective in dragging the subcutaneous tubing between the two incisions. No obvious damage to the skin from the overlying magnet was seen in any specimen.

Conclusions: Few options exist for tunneling distal shunt tubing for CSF shunt procedures. Future patient studies are needed to determine if the technique described herein is superior to current methods, particularly when examining patient groups that are at a greater risk for injury during tunneling shunt catheters.

Original languageEnglish (US)
Pages (from-to)2115-2117
Number of pages3
JournalChild's Nervous System
Volume30
Issue number12
DOIs
StatePublished - 2014

Fingerprint

Cerebrospinal Fluid Shunts
Magnets
Skin
Clavicle
Supine Position
Feasibility Studies
Ceramics
Hydrocephalus
Nickel
Cadaver
Catheters
Wounds and Injuries

Keywords

  • Hydrocephalus
  • Neurosurgery
  • Shunt
  • Treatment

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Clinical Neurology
  • Medicine(all)

Cite this

A novel method for passing cerebrospinal fluid shunt tubing : a proof of principle study. / Tubbs, R. Shane; Goodrich, Dylan; Tubbs, Isaiah; Loukas, Marios; Cohen-Gadol, Aaron.

In: Child's Nervous System, Vol. 30, No. 12, 2014, p. 2115-2117.

Research output: Contribution to journalArticle

Tubbs, R. Shane ; Goodrich, Dylan ; Tubbs, Isaiah ; Loukas, Marios ; Cohen-Gadol, Aaron. / A novel method for passing cerebrospinal fluid shunt tubing : a proof of principle study. In: Child's Nervous System. 2014 ; Vol. 30, No. 12. pp. 2115-2117.
@article{1d39287ea17c4f4f9b3a2ddc6460a057,
title = "A novel method for passing cerebrospinal fluid shunt tubing: a proof of principle study",
abstract = "Materials and methods: On 10 cadaver sides and when placed in the supine position, small skin incisions were made at the clavicle and ipsilateral subcostal region, and magnets were used to pass standard shunt tubing between the two incisions.Introduction: Few innovations in the method of tunneling shunt tubing for cerebrospinal fluid (CSF) shunt diversion have been made since this treatment of hydrocephalus was first developed. Therefore, this feasibility study was performed with the hope of identifying an improved technique that could potentially carry fewer complications.Results: Nickel-plated magnets were less effective in pulling the shunt tubing below the skin compared with ceramic magnets. Of these, magnets with pull strengths of 150–200 lbs were the most effective in dragging the subcutaneous tubing between the two incisions. No obvious damage to the skin from the overlying magnet was seen in any specimen.Conclusions: Few options exist for tunneling distal shunt tubing for CSF shunt procedures. Future patient studies are needed to determine if the technique described herein is superior to current methods, particularly when examining patient groups that are at a greater risk for injury during tunneling shunt catheters.",
keywords = "Hydrocephalus, Neurosurgery, Shunt, Treatment",
author = "Tubbs, {R. Shane} and Dylan Goodrich and Isaiah Tubbs and Marios Loukas and Aaron Cohen-Gadol",
year = "2014",
doi = "10.1007/s00381-014-2521-5",
language = "English (US)",
volume = "30",
pages = "2115--2117",
journal = "Child's Nervous System",
issn = "0256-7040",
publisher = "Springer Verlag",
number = "12",

}

TY - JOUR

T1 - A novel method for passing cerebrospinal fluid shunt tubing

T2 - a proof of principle study

AU - Tubbs, R. Shane

AU - Goodrich, Dylan

AU - Tubbs, Isaiah

AU - Loukas, Marios

AU - Cohen-Gadol, Aaron

PY - 2014

Y1 - 2014

N2 - Materials and methods: On 10 cadaver sides and when placed in the supine position, small skin incisions were made at the clavicle and ipsilateral subcostal region, and magnets were used to pass standard shunt tubing between the two incisions.Introduction: Few innovations in the method of tunneling shunt tubing for cerebrospinal fluid (CSF) shunt diversion have been made since this treatment of hydrocephalus was first developed. Therefore, this feasibility study was performed with the hope of identifying an improved technique that could potentially carry fewer complications.Results: Nickel-plated magnets were less effective in pulling the shunt tubing below the skin compared with ceramic magnets. Of these, magnets with pull strengths of 150–200 lbs were the most effective in dragging the subcutaneous tubing between the two incisions. No obvious damage to the skin from the overlying magnet was seen in any specimen.Conclusions: Few options exist for tunneling distal shunt tubing for CSF shunt procedures. Future patient studies are needed to determine if the technique described herein is superior to current methods, particularly when examining patient groups that are at a greater risk for injury during tunneling shunt catheters.

AB - Materials and methods: On 10 cadaver sides and when placed in the supine position, small skin incisions were made at the clavicle and ipsilateral subcostal region, and magnets were used to pass standard shunt tubing between the two incisions.Introduction: Few innovations in the method of tunneling shunt tubing for cerebrospinal fluid (CSF) shunt diversion have been made since this treatment of hydrocephalus was first developed. Therefore, this feasibility study was performed with the hope of identifying an improved technique that could potentially carry fewer complications.Results: Nickel-plated magnets were less effective in pulling the shunt tubing below the skin compared with ceramic magnets. Of these, magnets with pull strengths of 150–200 lbs were the most effective in dragging the subcutaneous tubing between the two incisions. No obvious damage to the skin from the overlying magnet was seen in any specimen.Conclusions: Few options exist for tunneling distal shunt tubing for CSF shunt procedures. Future patient studies are needed to determine if the technique described herein is superior to current methods, particularly when examining patient groups that are at a greater risk for injury during tunneling shunt catheters.

KW - Hydrocephalus

KW - Neurosurgery

KW - Shunt

KW - Treatment

UR - http://www.scopus.com/inward/record.url?scp=84937965677&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84937965677&partnerID=8YFLogxK

U2 - 10.1007/s00381-014-2521-5

DO - 10.1007/s00381-014-2521-5

M3 - Article

C2 - 25129404

AN - SCOPUS:84937965677

VL - 30

SP - 2115

EP - 2117

JO - Child's Nervous System

JF - Child's Nervous System

SN - 0256-7040

IS - 12

ER -