Accuracy and reliability of cone-beam computed tomography for airway volume analysis

Ahmed Ghoneima, Katherine Kula

Research output: Contribution to journalArticle

39 Citations (Scopus)

Abstract

The purpose of the present study was to evaluate the accuracy and reliability of airway volume digital measurements of cone-beam computed tomography (CBCT) compared with the manual measurements of an airway model. An acrylic airway model was constructed and attached to a human dry skull in the natural position of the airway passage. The total and internal airway volumes, as well as the most constricted airway area, were measured manually on the model and on the CBCTs taken after the model was attached to the skull. The CBCT images were analysed using the Dolphin3D (Dolphin Imaging & Management solutions, Chatsworth, California, USA) software. Reliability and accuracy were assessed by using intraclass correlation and Student's t-test. A P ≤ 0.05 was considered statistically significant. No significant statistical difference was found between the total, the internal airway volume, and the most constricted airway area measured on CBCTs compared with the manual measurements. The intra-examiner reliability was high for all measurements recorded from both methods (r ≥ 0.90). These results suggested that the three-dimensional CBCT digital measurements of the airway volume and the most constricted area of the airway are reliable and accurate. The use of CBCT imaging for the assessment of the airway can provide clinically useful information in orthodontics.

Original languageEnglish (US)
Pages (from-to)256-261
Number of pages6
JournalEuropean Journal of Orthodontics
Volume35
Issue number2
DOIs
StatePublished - Apr 2013
Externally publishedYes

Fingerprint

Cone-Beam Computed Tomography
Skull
Dolphins
Orthodontics
Software
Students

ASJC Scopus subject areas

  • Orthodontics

Cite this

Accuracy and reliability of cone-beam computed tomography for airway volume analysis. / Ghoneima, Ahmed; Kula, Katherine.

In: European Journal of Orthodontics, Vol. 35, No. 2, 04.2013, p. 256-261.

Research output: Contribution to journalArticle

Ghoneima, Ahmed ; Kula, Katherine. / Accuracy and reliability of cone-beam computed tomography for airway volume analysis. In: European Journal of Orthodontics. 2013 ; Vol. 35, No. 2. pp. 256-261.
@article{dfd9861c977b433e8eba5b3835f1542a,
title = "Accuracy and reliability of cone-beam computed tomography for airway volume analysis",
abstract = "The purpose of the present study was to evaluate the accuracy and reliability of airway volume digital measurements of cone-beam computed tomography (CBCT) compared with the manual measurements of an airway model. An acrylic airway model was constructed and attached to a human dry skull in the natural position of the airway passage. The total and internal airway volumes, as well as the most constricted airway area, were measured manually on the model and on the CBCTs taken after the model was attached to the skull. The CBCT images were analysed using the Dolphin3D (Dolphin Imaging & Management solutions, Chatsworth, California, USA) software. Reliability and accuracy were assessed by using intraclass correlation and Student's t-test. A P ≤ 0.05 was considered statistically significant. No significant statistical difference was found between the total, the internal airway volume, and the most constricted airway area measured on CBCTs compared with the manual measurements. The intra-examiner reliability was high for all measurements recorded from both methods (r ≥ 0.90). These results suggested that the three-dimensional CBCT digital measurements of the airway volume and the most constricted area of the airway are reliable and accurate. The use of CBCT imaging for the assessment of the airway can provide clinically useful information in orthodontics.",
author = "Ahmed Ghoneima and Katherine Kula",
year = "2013",
month = "4",
doi = "10.1093/ejo/cjr099",
language = "English (US)",
volume = "35",
pages = "256--261",
journal = "European Journal of Orthodontics",
issn = "0141-5387",
publisher = "Oxford University Press",
number = "2",

}

TY - JOUR

T1 - Accuracy and reliability of cone-beam computed tomography for airway volume analysis

AU - Ghoneima, Ahmed

AU - Kula, Katherine

PY - 2013/4

Y1 - 2013/4

N2 - The purpose of the present study was to evaluate the accuracy and reliability of airway volume digital measurements of cone-beam computed tomography (CBCT) compared with the manual measurements of an airway model. An acrylic airway model was constructed and attached to a human dry skull in the natural position of the airway passage. The total and internal airway volumes, as well as the most constricted airway area, were measured manually on the model and on the CBCTs taken after the model was attached to the skull. The CBCT images were analysed using the Dolphin3D (Dolphin Imaging & Management solutions, Chatsworth, California, USA) software. Reliability and accuracy were assessed by using intraclass correlation and Student's t-test. A P ≤ 0.05 was considered statistically significant. No significant statistical difference was found between the total, the internal airway volume, and the most constricted airway area measured on CBCTs compared with the manual measurements. The intra-examiner reliability was high for all measurements recorded from both methods (r ≥ 0.90). These results suggested that the three-dimensional CBCT digital measurements of the airway volume and the most constricted area of the airway are reliable and accurate. The use of CBCT imaging for the assessment of the airway can provide clinically useful information in orthodontics.

AB - The purpose of the present study was to evaluate the accuracy and reliability of airway volume digital measurements of cone-beam computed tomography (CBCT) compared with the manual measurements of an airway model. An acrylic airway model was constructed and attached to a human dry skull in the natural position of the airway passage. The total and internal airway volumes, as well as the most constricted airway area, were measured manually on the model and on the CBCTs taken after the model was attached to the skull. The CBCT images were analysed using the Dolphin3D (Dolphin Imaging & Management solutions, Chatsworth, California, USA) software. Reliability and accuracy were assessed by using intraclass correlation and Student's t-test. A P ≤ 0.05 was considered statistically significant. No significant statistical difference was found between the total, the internal airway volume, and the most constricted airway area measured on CBCTs compared with the manual measurements. The intra-examiner reliability was high for all measurements recorded from both methods (r ≥ 0.90). These results suggested that the three-dimensional CBCT digital measurements of the airway volume and the most constricted area of the airway are reliable and accurate. The use of CBCT imaging for the assessment of the airway can provide clinically useful information in orthodontics.

UR - http://www.scopus.com/inward/record.url?scp=84875725922&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84875725922&partnerID=8YFLogxK

U2 - 10.1093/ejo/cjr099

DO - 10.1093/ejo/cjr099

M3 - Article

C2 - 21832270

AN - SCOPUS:84875725922

VL - 35

SP - 256

EP - 261

JO - European Journal of Orthodontics

JF - European Journal of Orthodontics

SN - 0141-5387

IS - 2

ER -