An automated analysis program for the evaluation of cardiac PET studies

Initial results in the detection and localization of coronary artery disease using nitrogen-13-ammonia

C. Laubenbacher, J. Rothley, J. Sitomer, R. Beanlands, Stephen Sawada, R. Sutor, D. Muller, M. Schwaiger

Research output: Contribution to journalArticle

57 Citations (Scopus)

Abstract

Positron emission tomography (PET), in combination with myocardial blood flow tracers, allows highly accurate diagnosis of coronary artery disease using visual data interpretation. To increase the objectivity of data analysis and to reduce interobserver variability, we developed an automated analysis method for the three-dimensional definition of myocardial activity, which includes true volumetric data extraction and mathematical constraints of activity sampling to the expected shape of the left ventricle. Data are displayed in a standardized polar map or three-dimensional format for comparison with a normal database. The first clinical evaluation of this method in 52 patients using receiver operating characteristics (ROC) curve analysis demonstrated high diagnostic accuracy for detection as well as localization of coronary artery stenosis in predefined vascular territories. The interobserver and intraobserver agreement for localization of disease was excellent, with correlation coefficients varying from 0.85 to 0.99 for individual vascular territories. Thus, this automated quantitative analysis program provides highly accurate and reproducible evaluation of cardiac PET flow studies. Definite determination of its diagnostic accuracy requires a prospective multicenter trial in a larger patient population employing the criteria for abnormality established in this initial clinical evaluation.

Original languageEnglish (US)
Pages (from-to)968-978
Number of pages11
JournalJournal of Nuclear Medicine
Volume34
Issue number6
StatePublished - 1993
Externally publishedYes

Fingerprint

Program Evaluation
Ammonia
Positron-Emission Tomography
Coronary Artery Disease
Nitrogen
Blood Vessels
Observer Variation
Coronary Stenosis
ROC Curve
Multicenter Studies
Heart Ventricles
Databases
Population

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

An automated analysis program for the evaluation of cardiac PET studies : Initial results in the detection and localization of coronary artery disease using nitrogen-13-ammonia. / Laubenbacher, C.; Rothley, J.; Sitomer, J.; Beanlands, R.; Sawada, Stephen; Sutor, R.; Muller, D.; Schwaiger, M.

In: Journal of Nuclear Medicine, Vol. 34, No. 6, 1993, p. 968-978.

Research output: Contribution to journalArticle

@article{a73f652b39324a74b848de7d328afec6,
title = "An automated analysis program for the evaluation of cardiac PET studies: Initial results in the detection and localization of coronary artery disease using nitrogen-13-ammonia",
abstract = "Positron emission tomography (PET), in combination with myocardial blood flow tracers, allows highly accurate diagnosis of coronary artery disease using visual data interpretation. To increase the objectivity of data analysis and to reduce interobserver variability, we developed an automated analysis method for the three-dimensional definition of myocardial activity, which includes true volumetric data extraction and mathematical constraints of activity sampling to the expected shape of the left ventricle. Data are displayed in a standardized polar map or three-dimensional format for comparison with a normal database. The first clinical evaluation of this method in 52 patients using receiver operating characteristics (ROC) curve analysis demonstrated high diagnostic accuracy for detection as well as localization of coronary artery stenosis in predefined vascular territories. The interobserver and intraobserver agreement for localization of disease was excellent, with correlation coefficients varying from 0.85 to 0.99 for individual vascular territories. Thus, this automated quantitative analysis program provides highly accurate and reproducible evaluation of cardiac PET flow studies. Definite determination of its diagnostic accuracy requires a prospective multicenter trial in a larger patient population employing the criteria for abnormality established in this initial clinical evaluation.",
author = "C. Laubenbacher and J. Rothley and J. Sitomer and R. Beanlands and Stephen Sawada and R. Sutor and D. Muller and M. Schwaiger",
year = "1993",
language = "English (US)",
volume = "34",
pages = "968--978",
journal = "Journal of Nuclear Medicine",
issn = "0161-5505",
publisher = "Society of Nuclear Medicine Inc.",
number = "6",

}

TY - JOUR

T1 - An automated analysis program for the evaluation of cardiac PET studies

T2 - Initial results in the detection and localization of coronary artery disease using nitrogen-13-ammonia

AU - Laubenbacher, C.

AU - Rothley, J.

AU - Sitomer, J.

AU - Beanlands, R.

AU - Sawada, Stephen

AU - Sutor, R.

AU - Muller, D.

AU - Schwaiger, M.

PY - 1993

Y1 - 1993

N2 - Positron emission tomography (PET), in combination with myocardial blood flow tracers, allows highly accurate diagnosis of coronary artery disease using visual data interpretation. To increase the objectivity of data analysis and to reduce interobserver variability, we developed an automated analysis method for the three-dimensional definition of myocardial activity, which includes true volumetric data extraction and mathematical constraints of activity sampling to the expected shape of the left ventricle. Data are displayed in a standardized polar map or three-dimensional format for comparison with a normal database. The first clinical evaluation of this method in 52 patients using receiver operating characteristics (ROC) curve analysis demonstrated high diagnostic accuracy for detection as well as localization of coronary artery stenosis in predefined vascular territories. The interobserver and intraobserver agreement for localization of disease was excellent, with correlation coefficients varying from 0.85 to 0.99 for individual vascular territories. Thus, this automated quantitative analysis program provides highly accurate and reproducible evaluation of cardiac PET flow studies. Definite determination of its diagnostic accuracy requires a prospective multicenter trial in a larger patient population employing the criteria for abnormality established in this initial clinical evaluation.

AB - Positron emission tomography (PET), in combination with myocardial blood flow tracers, allows highly accurate diagnosis of coronary artery disease using visual data interpretation. To increase the objectivity of data analysis and to reduce interobserver variability, we developed an automated analysis method for the three-dimensional definition of myocardial activity, which includes true volumetric data extraction and mathematical constraints of activity sampling to the expected shape of the left ventricle. Data are displayed in a standardized polar map or three-dimensional format for comparison with a normal database. The first clinical evaluation of this method in 52 patients using receiver operating characteristics (ROC) curve analysis demonstrated high diagnostic accuracy for detection as well as localization of coronary artery stenosis in predefined vascular territories. The interobserver and intraobserver agreement for localization of disease was excellent, with correlation coefficients varying from 0.85 to 0.99 for individual vascular territories. Thus, this automated quantitative analysis program provides highly accurate and reproducible evaluation of cardiac PET flow studies. Definite determination of its diagnostic accuracy requires a prospective multicenter trial in a larger patient population employing the criteria for abnormality established in this initial clinical evaluation.

UR - http://www.scopus.com/inward/record.url?scp=0027211982&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027211982&partnerID=8YFLogxK

M3 - Article

VL - 34

SP - 968

EP - 978

JO - Journal of Nuclear Medicine

JF - Journal of Nuclear Medicine

SN - 0161-5505

IS - 6

ER -