Buzz in the axilla

A new physical sign in hemodialysis forearm graft evaluation

Rajiv Agarwal, Grant McDougal

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The value of physical signs in predicting flow rates or polytetrafluoroethylene (PTFE) hemodialysis graft survival is not well known. Simultaneous physical examination and flow measurements were performed in 67 dialysis patients with PTFE grafts over a period of 1 month. Physical signs included the presence and location of a palpable thrill, location and auscultatory nature of the bruit, and presence or absence of a pulsation. Patients were followed up for 1 year to detect the time to failure defined by angioplasty, clotting, or surgical revision. There was a fair correlation between physical signs and graft flow rates. In a multivariate model, systolic blood pressure, location of the thrill, and patient age were the best predictors of graft flow. During follow-up, there were 68 graft failures (30 grafts, angioplasty alone; 38 grafts, thrombosis followed by interventional or surgical revisions). The median survival of a graft without a thrill in the axilla was 154 days compared with 321 days when a thrill was present (P=0.05, log-rank test). Dialysis graft physical examination is a useful test to predict graft flows, as well as graft failure. The single best test is the location of the thrill along the venous limb of the graft. Average flow rates for no thrill, thrill but distal to the midarm, and axillary buzz were approximately 500, 750, and 1,000 mL/min, respectively. This single physical sign also correlated with subsequent graft failure and should be incorporated into physical examinations of all dialysis grafts.

Original languageEnglish
Pages (from-to)853-857
Number of pages5
JournalAmerican Journal of Kidney Diseases
Volume38
Issue number4
StatePublished - 2001

Fingerprint

Axilla
Forearm
Renal Dialysis
Transplants
Physical Examination
Dialysis
Polytetrafluoroethylene
Graft Survival
Reoperation
Angioplasty
Blood Pressure
Thrombosis
Extremities

Keywords

  • Hemodialysis (HD)
  • Hemodialysis (HD) graft
  • Physical examination
  • Vascular access

ASJC Scopus subject areas

  • Nephrology

Cite this

Buzz in the axilla : A new physical sign in hemodialysis forearm graft evaluation. / Agarwal, Rajiv; McDougal, Grant.

In: American Journal of Kidney Diseases, Vol. 38, No. 4, 2001, p. 853-857.

Research output: Contribution to journalArticle

@article{8cc6e46ab375463396b5fa8bb464e88f,
title = "Buzz in the axilla: A new physical sign in hemodialysis forearm graft evaluation",
abstract = "The value of physical signs in predicting flow rates or polytetrafluoroethylene (PTFE) hemodialysis graft survival is not well known. Simultaneous physical examination and flow measurements were performed in 67 dialysis patients with PTFE grafts over a period of 1 month. Physical signs included the presence and location of a palpable thrill, location and auscultatory nature of the bruit, and presence or absence of a pulsation. Patients were followed up for 1 year to detect the time to failure defined by angioplasty, clotting, or surgical revision. There was a fair correlation between physical signs and graft flow rates. In a multivariate model, systolic blood pressure, location of the thrill, and patient age were the best predictors of graft flow. During follow-up, there were 68 graft failures (30 grafts, angioplasty alone; 38 grafts, thrombosis followed by interventional or surgical revisions). The median survival of a graft without a thrill in the axilla was 154 days compared with 321 days when a thrill was present (P=0.05, log-rank test). Dialysis graft physical examination is a useful test to predict graft flows, as well as graft failure. The single best test is the location of the thrill along the venous limb of the graft. Average flow rates for no thrill, thrill but distal to the midarm, and axillary buzz were approximately 500, 750, and 1,000 mL/min, respectively. This single physical sign also correlated with subsequent graft failure and should be incorporated into physical examinations of all dialysis grafts.",
keywords = "Hemodialysis (HD), Hemodialysis (HD) graft, Physical examination, Vascular access",
author = "Rajiv Agarwal and Grant McDougal",
year = "2001",
language = "English",
volume = "38",
pages = "853--857",
journal = "American Journal of Kidney Diseases",
issn = "0272-6386",
publisher = "W.B. Saunders Ltd",
number = "4",

}

TY - JOUR

T1 - Buzz in the axilla

T2 - A new physical sign in hemodialysis forearm graft evaluation

AU - Agarwal, Rajiv

AU - McDougal, Grant

PY - 2001

Y1 - 2001

N2 - The value of physical signs in predicting flow rates or polytetrafluoroethylene (PTFE) hemodialysis graft survival is not well known. Simultaneous physical examination and flow measurements were performed in 67 dialysis patients with PTFE grafts over a period of 1 month. Physical signs included the presence and location of a palpable thrill, location and auscultatory nature of the bruit, and presence or absence of a pulsation. Patients were followed up for 1 year to detect the time to failure defined by angioplasty, clotting, or surgical revision. There was a fair correlation between physical signs and graft flow rates. In a multivariate model, systolic blood pressure, location of the thrill, and patient age were the best predictors of graft flow. During follow-up, there were 68 graft failures (30 grafts, angioplasty alone; 38 grafts, thrombosis followed by interventional or surgical revisions). The median survival of a graft without a thrill in the axilla was 154 days compared with 321 days when a thrill was present (P=0.05, log-rank test). Dialysis graft physical examination is a useful test to predict graft flows, as well as graft failure. The single best test is the location of the thrill along the venous limb of the graft. Average flow rates for no thrill, thrill but distal to the midarm, and axillary buzz were approximately 500, 750, and 1,000 mL/min, respectively. This single physical sign also correlated with subsequent graft failure and should be incorporated into physical examinations of all dialysis grafts.

AB - The value of physical signs in predicting flow rates or polytetrafluoroethylene (PTFE) hemodialysis graft survival is not well known. Simultaneous physical examination and flow measurements were performed in 67 dialysis patients with PTFE grafts over a period of 1 month. Physical signs included the presence and location of a palpable thrill, location and auscultatory nature of the bruit, and presence or absence of a pulsation. Patients were followed up for 1 year to detect the time to failure defined by angioplasty, clotting, or surgical revision. There was a fair correlation between physical signs and graft flow rates. In a multivariate model, systolic blood pressure, location of the thrill, and patient age were the best predictors of graft flow. During follow-up, there were 68 graft failures (30 grafts, angioplasty alone; 38 grafts, thrombosis followed by interventional or surgical revisions). The median survival of a graft without a thrill in the axilla was 154 days compared with 321 days when a thrill was present (P=0.05, log-rank test). Dialysis graft physical examination is a useful test to predict graft flows, as well as graft failure. The single best test is the location of the thrill along the venous limb of the graft. Average flow rates for no thrill, thrill but distal to the midarm, and axillary buzz were approximately 500, 750, and 1,000 mL/min, respectively. This single physical sign also correlated with subsequent graft failure and should be incorporated into physical examinations of all dialysis grafts.

KW - Hemodialysis (HD)

KW - Hemodialysis (HD) graft

KW - Physical examination

KW - Vascular access

UR - http://www.scopus.com/inward/record.url?scp=0034809842&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034809842&partnerID=8YFLogxK

M3 - Article

VL - 38

SP - 853

EP - 857

JO - American Journal of Kidney Diseases

JF - American Journal of Kidney Diseases

SN - 0272-6386

IS - 4

ER -