Can current technology be integrated to facilitate laparoscopic living donor hepatectomy?

E. Lin, R. Gonzalez, K. R. Venkatesh, S. G. Mattar, S. P. Bowers, K. M. Fugate, T. G. Heffron, C. D. Smith

Research output: Contribution to journalArticle

23 Citations (Scopus)

Abstract

Background: Living donor hepatectomy (LDH) is a technically demanding procedure that is an alternative for providing livers for transplantation. Unlike liver resections for other pathology, LDH requires preservation of the major vessels and biliary tree. This study was performed to determine if current technology can be integrated to perform laparoscopic LDH. Methods: Six adult sheep underwent laparoscopic LDH of the left lateral segment under general anesthesia. Instruments utilized included standard dissecting instruments, ultrasound, ultrasonic dissectors, CUSA, the TissueLink Floating Ball, and endoscopic staplers. Results: LDH-harvested liver grafts were 44% of whole liver weight. Estimated blood loss was 300 cc. Warm ischemia time was 5-7 min. Grafts were delivered through 18-cm abdominal wounds. Major vessels and biliary anatomy were positively identified in the grafts. Conclusions: Laparoscopic LDH can be performed with available technology. Theoretical advantages include reduced liver manipulation and smaller wound size.

Original languageEnglish (US)
Pages (from-to)750-753
Number of pages4
JournalSurgical Endoscopy and Other Interventional Techniques
Volume17
Issue number5
DOIs
StatePublished - May 1 2003
Externally publishedYes

Fingerprint

Living Donors
Hepatectomy
Technology
Liver
Transplants
Warm Ischemia
Wounds and Injuries
Biliary Tract
Ultrasonics
Liver Transplantation
General Anesthesia
Anatomy
Sheep
Pathology
Weights and Measures

Keywords

  • Graft preservation
  • Instrument technology
  • Laparoscopic hepatectomy
  • Liver transplant
  • Living donor

ASJC Scopus subject areas

  • Surgery

Cite this

Lin, E., Gonzalez, R., Venkatesh, K. R., Mattar, S. G., Bowers, S. P., Fugate, K. M., ... Smith, C. D. (2003). Can current technology be integrated to facilitate laparoscopic living donor hepatectomy? Surgical Endoscopy and Other Interventional Techniques, 17(5), 750-753. https://doi.org/10.1007/s00464-002-8858-y

Can current technology be integrated to facilitate laparoscopic living donor hepatectomy? / Lin, E.; Gonzalez, R.; Venkatesh, K. R.; Mattar, S. G.; Bowers, S. P.; Fugate, K. M.; Heffron, T. G.; Smith, C. D.

In: Surgical Endoscopy and Other Interventional Techniques, Vol. 17, No. 5, 01.05.2003, p. 750-753.

Research output: Contribution to journalArticle

Lin, E, Gonzalez, R, Venkatesh, KR, Mattar, SG, Bowers, SP, Fugate, KM, Heffron, TG & Smith, CD 2003, 'Can current technology be integrated to facilitate laparoscopic living donor hepatectomy?', Surgical Endoscopy and Other Interventional Techniques, vol. 17, no. 5, pp. 750-753. https://doi.org/10.1007/s00464-002-8858-y
Lin, E. ; Gonzalez, R. ; Venkatesh, K. R. ; Mattar, S. G. ; Bowers, S. P. ; Fugate, K. M. ; Heffron, T. G. ; Smith, C. D. / Can current technology be integrated to facilitate laparoscopic living donor hepatectomy?. In: Surgical Endoscopy and Other Interventional Techniques. 2003 ; Vol. 17, No. 5. pp. 750-753.
@article{ad8a4d1031474f3caa302398b4256f61,
title = "Can current technology be integrated to facilitate laparoscopic living donor hepatectomy?",
abstract = "Background: Living donor hepatectomy (LDH) is a technically demanding procedure that is an alternative for providing livers for transplantation. Unlike liver resections for other pathology, LDH requires preservation of the major vessels and biliary tree. This study was performed to determine if current technology can be integrated to perform laparoscopic LDH. Methods: Six adult sheep underwent laparoscopic LDH of the left lateral segment under general anesthesia. Instruments utilized included standard dissecting instruments, ultrasound, ultrasonic dissectors, CUSA, the TissueLink Floating Ball, and endoscopic staplers. Results: LDH-harvested liver grafts were 44{\%} of whole liver weight. Estimated blood loss was 300 cc. Warm ischemia time was 5-7 min. Grafts were delivered through 18-cm abdominal wounds. Major vessels and biliary anatomy were positively identified in the grafts. Conclusions: Laparoscopic LDH can be performed with available technology. Theoretical advantages include reduced liver manipulation and smaller wound size.",
keywords = "Graft preservation, Instrument technology, Laparoscopic hepatectomy, Liver transplant, Living donor",
author = "E. Lin and R. Gonzalez and Venkatesh, {K. R.} and Mattar, {S. G.} and Bowers, {S. P.} and Fugate, {K. M.} and Heffron, {T. G.} and Smith, {C. D.}",
year = "2003",
month = "5",
day = "1",
doi = "10.1007/s00464-002-8858-y",
language = "English (US)",
volume = "17",
pages = "750--753",
journal = "Surgical Endoscopy",
issn = "0930-2794",
publisher = "Springer New York",
number = "5",

}

TY - JOUR

T1 - Can current technology be integrated to facilitate laparoscopic living donor hepatectomy?

AU - Lin, E.

AU - Gonzalez, R.

AU - Venkatesh, K. R.

AU - Mattar, S. G.

AU - Bowers, S. P.

AU - Fugate, K. M.

AU - Heffron, T. G.

AU - Smith, C. D.

PY - 2003/5/1

Y1 - 2003/5/1

N2 - Background: Living donor hepatectomy (LDH) is a technically demanding procedure that is an alternative for providing livers for transplantation. Unlike liver resections for other pathology, LDH requires preservation of the major vessels and biliary tree. This study was performed to determine if current technology can be integrated to perform laparoscopic LDH. Methods: Six adult sheep underwent laparoscopic LDH of the left lateral segment under general anesthesia. Instruments utilized included standard dissecting instruments, ultrasound, ultrasonic dissectors, CUSA, the TissueLink Floating Ball, and endoscopic staplers. Results: LDH-harvested liver grafts were 44% of whole liver weight. Estimated blood loss was 300 cc. Warm ischemia time was 5-7 min. Grafts were delivered through 18-cm abdominal wounds. Major vessels and biliary anatomy were positively identified in the grafts. Conclusions: Laparoscopic LDH can be performed with available technology. Theoretical advantages include reduced liver manipulation and smaller wound size.

AB - Background: Living donor hepatectomy (LDH) is a technically demanding procedure that is an alternative for providing livers for transplantation. Unlike liver resections for other pathology, LDH requires preservation of the major vessels and biliary tree. This study was performed to determine if current technology can be integrated to perform laparoscopic LDH. Methods: Six adult sheep underwent laparoscopic LDH of the left lateral segment under general anesthesia. Instruments utilized included standard dissecting instruments, ultrasound, ultrasonic dissectors, CUSA, the TissueLink Floating Ball, and endoscopic staplers. Results: LDH-harvested liver grafts were 44% of whole liver weight. Estimated blood loss was 300 cc. Warm ischemia time was 5-7 min. Grafts were delivered through 18-cm abdominal wounds. Major vessels and biliary anatomy were positively identified in the grafts. Conclusions: Laparoscopic LDH can be performed with available technology. Theoretical advantages include reduced liver manipulation and smaller wound size.

KW - Graft preservation

KW - Instrument technology

KW - Laparoscopic hepatectomy

KW - Liver transplant

KW - Living donor

UR - http://www.scopus.com/inward/record.url?scp=0038752886&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0038752886&partnerID=8YFLogxK

U2 - 10.1007/s00464-002-8858-y

DO - 10.1007/s00464-002-8858-y

M3 - Article

VL - 17

SP - 750

EP - 753

JO - Surgical Endoscopy

JF - Surgical Endoscopy

SN - 0930-2794

IS - 5

ER -