Can Intraoperative Sensors Determine the "Target" Ligament Balance? Early Outcomes in Total Knee Arthroplasty

R. Meneghini, Mary M. Ziemba-Davis, Luke R. Lovro, Phillip H. Ireland, Brent M. Damer

Research output: Contribution to journalArticle

31 Citations (Scopus)

Abstract

Background: The optimal "target" ligament balance for each patient undergoing total knee arthroplasty (TKA) remains unknown. The study purpose was to determine if patient outcomes are affected by intraoperative ligament balance measured with force-sensing implant trials and if an optimal "target" balance exists. Methods: A multicenter, retrospective study reviewed consecutive TKAs performed by 3 surgeons. TKA's were performed with standard surgical techniques and ligament releases. After final implants were made, sensor-embedded smart tibial trials were inserted, and compartment forces recorded throughout the range of motion. Clinical outcome measures were obtained preoperatively and at 4 months. Statistical analysis correlated ligament balance with clinical outcomes. Results: One hundred eighty-nine consecutive TKAs were analyzed. Patients were grouped by average medial and lateral compartment force differences. Twenty-nine TKAs (15%) were balanced within 15 lbs and 53 (28%) were "balanced" greater than 75 lbs. Greater improvement in University of California Los Angeles activity level was associated with a mediolateral force difference

Original languageEnglish (US)
JournalJournal of Arthroplasty
DOIs
StateAccepted/In press - Dec 21 2015

Fingerprint

Knee Replacement Arthroplasties
Ligaments
Los Angeles
Articular Range of Motion
Multicenter Studies
Retrospective Studies
Outcome Assessment (Health Care)

Keywords

  • Ligament balance
  • Outcomes
  • Sensor
  • Smart tibial trials
  • Total knee arthroplasty

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Can Intraoperative Sensors Determine the "Target" Ligament Balance? Early Outcomes in Total Knee Arthroplasty. / Meneghini, R.; Ziemba-Davis, Mary M.; Lovro, Luke R.; Ireland, Phillip H.; Damer, Brent M.

In: Journal of Arthroplasty, 21.12.2015.

Research output: Contribution to journalArticle

Meneghini, R. ; Ziemba-Davis, Mary M. ; Lovro, Luke R. ; Ireland, Phillip H. ; Damer, Brent M. / Can Intraoperative Sensors Determine the "Target" Ligament Balance? Early Outcomes in Total Knee Arthroplasty. In: Journal of Arthroplasty. 2015.
@article{297f68c598cb4ee3ad1f461f92b2c908,
title = "Can Intraoperative Sensors Determine the {"}Target{"} Ligament Balance? Early Outcomes in Total Knee Arthroplasty",
abstract = "Background: The optimal {"}target{"} ligament balance for each patient undergoing total knee arthroplasty (TKA) remains unknown. The study purpose was to determine if patient outcomes are affected by intraoperative ligament balance measured with force-sensing implant trials and if an optimal {"}target{"} balance exists. Methods: A multicenter, retrospective study reviewed consecutive TKAs performed by 3 surgeons. TKA's were performed with standard surgical techniques and ligament releases. After final implants were made, sensor-embedded smart tibial trials were inserted, and compartment forces recorded throughout the range of motion. Clinical outcome measures were obtained preoperatively and at 4 months. Statistical analysis correlated ligament balance with clinical outcomes. Results: One hundred eighty-nine consecutive TKAs were analyzed. Patients were grouped by average medial and lateral compartment force differences. Twenty-nine TKAs (15{\%}) were balanced within 15 lbs and 53 (28{\%}) were {"}balanced{"} greater than 75 lbs. Greater improvement in University of California Los Angeles activity level was associated with a mediolateral force difference",
keywords = "Ligament balance, Outcomes, Sensor, Smart tibial trials, Total knee arthroplasty",
author = "R. Meneghini and Ziemba-Davis, {Mary M.} and Lovro, {Luke R.} and Ireland, {Phillip H.} and Damer, {Brent M.}",
year = "2015",
month = "12",
day = "21",
doi = "10.1016/j.arth.2016.03.046",
language = "English (US)",
journal = "Journal of Arthroplasty",
issn = "0883-5403",
publisher = "Churchill Livingstone",

}

TY - JOUR

T1 - Can Intraoperative Sensors Determine the "Target" Ligament Balance? Early Outcomes in Total Knee Arthroplasty

AU - Meneghini, R.

AU - Ziemba-Davis, Mary M.

AU - Lovro, Luke R.

AU - Ireland, Phillip H.

AU - Damer, Brent M.

PY - 2015/12/21

Y1 - 2015/12/21

N2 - Background: The optimal "target" ligament balance for each patient undergoing total knee arthroplasty (TKA) remains unknown. The study purpose was to determine if patient outcomes are affected by intraoperative ligament balance measured with force-sensing implant trials and if an optimal "target" balance exists. Methods: A multicenter, retrospective study reviewed consecutive TKAs performed by 3 surgeons. TKA's were performed with standard surgical techniques and ligament releases. After final implants were made, sensor-embedded smart tibial trials were inserted, and compartment forces recorded throughout the range of motion. Clinical outcome measures were obtained preoperatively and at 4 months. Statistical analysis correlated ligament balance with clinical outcomes. Results: One hundred eighty-nine consecutive TKAs were analyzed. Patients were grouped by average medial and lateral compartment force differences. Twenty-nine TKAs (15%) were balanced within 15 lbs and 53 (28%) were "balanced" greater than 75 lbs. Greater improvement in University of California Los Angeles activity level was associated with a mediolateral force difference

AB - Background: The optimal "target" ligament balance for each patient undergoing total knee arthroplasty (TKA) remains unknown. The study purpose was to determine if patient outcomes are affected by intraoperative ligament balance measured with force-sensing implant trials and if an optimal "target" balance exists. Methods: A multicenter, retrospective study reviewed consecutive TKAs performed by 3 surgeons. TKA's were performed with standard surgical techniques and ligament releases. After final implants were made, sensor-embedded smart tibial trials were inserted, and compartment forces recorded throughout the range of motion. Clinical outcome measures were obtained preoperatively and at 4 months. Statistical analysis correlated ligament balance with clinical outcomes. Results: One hundred eighty-nine consecutive TKAs were analyzed. Patients were grouped by average medial and lateral compartment force differences. Twenty-nine TKAs (15%) were balanced within 15 lbs and 53 (28%) were "balanced" greater than 75 lbs. Greater improvement in University of California Los Angeles activity level was associated with a mediolateral force difference

KW - Ligament balance

KW - Outcomes

KW - Sensor

KW - Smart tibial trials

KW - Total knee arthroplasty

UR - http://www.scopus.com/inward/record.url?scp=84964809955&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84964809955&partnerID=8YFLogxK

U2 - 10.1016/j.arth.2016.03.046

DO - 10.1016/j.arth.2016.03.046

M3 - Article

JO - Journal of Arthroplasty

JF - Journal of Arthroplasty

SN - 0883-5403

ER -