Cervical spine instability: Clearance using dynamic fluoroscopy

Mitchell W. Cox, Mary McCarthy, Gary Lemmon, Josef Wenker

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Purpose Cle aring the cervical spine in a multiply injured trauma patient is a dilemma because clinical examination for ligamentous instability cannot be performed, and the standard cervical spine series can miss isolated ligamentous injury. Static flexion/extension views are unsafe, as the obtunded patient has no protective reflexes and cannot complain of pain during the exam. This results in a need for prolonged spinal immobilization and its attendant complications. Dynamic fluoroscopy may be useful in the detection of otherwise occult injuries. Methods We performed a prospective study of a cervical spine clearance algorithm incorporating dynamic fluoroscopy with flexion/extension views. Inpatient records over a 3-year period were reviewed. Patient demographic data, results of cervical spine films and fluoroscopic exams, interventions based on positive results, and missed injuries were recorded. Results One hundred ten patients with normal spine plain films underwent dynamic fluoroscopy with flexion and extension views of the cervical spine. The average Glasgow Coma Score was 9.2 and the average revised Trauma Score was 9.5. Nine patients had evidence of cervical instability on exam. Six of these were deemed stable by the orthopedic or neurosurgical spine consultants, and these patients had their hard collars removed. One patient with positive findings had cervical immobilization with hard collar continued, a second had halo placement, and a third underwent spinal fusion for atlanto-occipital disassociation. No patients undergoing dynamic fluoroscopy were subsequently found to have missed cervical spine injury. Conclusions With our protocol, 3 patients had significant cervical instability that would have been missed without dynamic fluoroscopy. Given the significant medical and legal ramifications of missed cervical spine injury and the benefits of early removal of cervical collars, more widespread use of dynamic fluoroscopy of the cervical spine is warranted.

Original languageEnglish (US)
Pages (from-to)96-100
Number of pages5
JournalCurrent Surgery
Volume58
Issue number1
DOIs
StatePublished - Jan 2001
Externally publishedYes

Fingerprint

Fluoroscopy
Spine
trauma
Wounds and Injuries
pain
Motion Pictures
examination
Immobilization
evidence
Spinal Fusion
Coma
Consultants
Orthopedics
Reflex
Inpatients
Demography
Prospective Studies
Pain

Keywords

  • Cervical collar
  • Cervical spine clearance
  • Cervical spine fracture
  • Dynamic fluoroscopy
  • Flexion-extension views

ASJC Scopus subject areas

  • Surgery

Cite this

Cervical spine instability : Clearance using dynamic fluoroscopy. / Cox, Mitchell W.; McCarthy, Mary; Lemmon, Gary; Wenker, Josef.

In: Current Surgery, Vol. 58, No. 1, 01.2001, p. 96-100.

Research output: Contribution to journalArticle

Cox, Mitchell W. ; McCarthy, Mary ; Lemmon, Gary ; Wenker, Josef. / Cervical spine instability : Clearance using dynamic fluoroscopy. In: Current Surgery. 2001 ; Vol. 58, No. 1. pp. 96-100.
@article{4a9f4167f52b48f3ade43a143a06796d,
title = "Cervical spine instability: Clearance using dynamic fluoroscopy",
abstract = "Purpose Cle aring the cervical spine in a multiply injured trauma patient is a dilemma because clinical examination for ligamentous instability cannot be performed, and the standard cervical spine series can miss isolated ligamentous injury. Static flexion/extension views are unsafe, as the obtunded patient has no protective reflexes and cannot complain of pain during the exam. This results in a need for prolonged spinal immobilization and its attendant complications. Dynamic fluoroscopy may be useful in the detection of otherwise occult injuries. Methods We performed a prospective study of a cervical spine clearance algorithm incorporating dynamic fluoroscopy with flexion/extension views. Inpatient records over a 3-year period were reviewed. Patient demographic data, results of cervical spine films and fluoroscopic exams, interventions based on positive results, and missed injuries were recorded. Results One hundred ten patients with normal spine plain films underwent dynamic fluoroscopy with flexion and extension views of the cervical spine. The average Glasgow Coma Score was 9.2 and the average revised Trauma Score was 9.5. Nine patients had evidence of cervical instability on exam. Six of these were deemed stable by the orthopedic or neurosurgical spine consultants, and these patients had their hard collars removed. One patient with positive findings had cervical immobilization with hard collar continued, a second had halo placement, and a third underwent spinal fusion for atlanto-occipital disassociation. No patients undergoing dynamic fluoroscopy were subsequently found to have missed cervical spine injury. Conclusions With our protocol, 3 patients had significant cervical instability that would have been missed without dynamic fluoroscopy. Given the significant medical and legal ramifications of missed cervical spine injury and the benefits of early removal of cervical collars, more widespread use of dynamic fluoroscopy of the cervical spine is warranted.",
keywords = "Cervical collar, Cervical spine clearance, Cervical spine fracture, Dynamic fluoroscopy, Flexion-extension views",
author = "Cox, {Mitchell W.} and Mary McCarthy and Gary Lemmon and Josef Wenker",
year = "2001",
month = "1",
doi = "10.1016/S0149-7944(00)00441-4",
language = "English (US)",
volume = "58",
pages = "96--100",
journal = "Journal of Surgical Education",
issn = "1931-7204",
publisher = "Elsevier Inc.",
number = "1",

}

TY - JOUR

T1 - Cervical spine instability

T2 - Clearance using dynamic fluoroscopy

AU - Cox, Mitchell W.

AU - McCarthy, Mary

AU - Lemmon, Gary

AU - Wenker, Josef

PY - 2001/1

Y1 - 2001/1

N2 - Purpose Cle aring the cervical spine in a multiply injured trauma patient is a dilemma because clinical examination for ligamentous instability cannot be performed, and the standard cervical spine series can miss isolated ligamentous injury. Static flexion/extension views are unsafe, as the obtunded patient has no protective reflexes and cannot complain of pain during the exam. This results in a need for prolonged spinal immobilization and its attendant complications. Dynamic fluoroscopy may be useful in the detection of otherwise occult injuries. Methods We performed a prospective study of a cervical spine clearance algorithm incorporating dynamic fluoroscopy with flexion/extension views. Inpatient records over a 3-year period were reviewed. Patient demographic data, results of cervical spine films and fluoroscopic exams, interventions based on positive results, and missed injuries were recorded. Results One hundred ten patients with normal spine plain films underwent dynamic fluoroscopy with flexion and extension views of the cervical spine. The average Glasgow Coma Score was 9.2 and the average revised Trauma Score was 9.5. Nine patients had evidence of cervical instability on exam. Six of these were deemed stable by the orthopedic or neurosurgical spine consultants, and these patients had their hard collars removed. One patient with positive findings had cervical immobilization with hard collar continued, a second had halo placement, and a third underwent spinal fusion for atlanto-occipital disassociation. No patients undergoing dynamic fluoroscopy were subsequently found to have missed cervical spine injury. Conclusions With our protocol, 3 patients had significant cervical instability that would have been missed without dynamic fluoroscopy. Given the significant medical and legal ramifications of missed cervical spine injury and the benefits of early removal of cervical collars, more widespread use of dynamic fluoroscopy of the cervical spine is warranted.

AB - Purpose Cle aring the cervical spine in a multiply injured trauma patient is a dilemma because clinical examination for ligamentous instability cannot be performed, and the standard cervical spine series can miss isolated ligamentous injury. Static flexion/extension views are unsafe, as the obtunded patient has no protective reflexes and cannot complain of pain during the exam. This results in a need for prolonged spinal immobilization and its attendant complications. Dynamic fluoroscopy may be useful in the detection of otherwise occult injuries. Methods We performed a prospective study of a cervical spine clearance algorithm incorporating dynamic fluoroscopy with flexion/extension views. Inpatient records over a 3-year period were reviewed. Patient demographic data, results of cervical spine films and fluoroscopic exams, interventions based on positive results, and missed injuries were recorded. Results One hundred ten patients with normal spine plain films underwent dynamic fluoroscopy with flexion and extension views of the cervical spine. The average Glasgow Coma Score was 9.2 and the average revised Trauma Score was 9.5. Nine patients had evidence of cervical instability on exam. Six of these were deemed stable by the orthopedic or neurosurgical spine consultants, and these patients had their hard collars removed. One patient with positive findings had cervical immobilization with hard collar continued, a second had halo placement, and a third underwent spinal fusion for atlanto-occipital disassociation. No patients undergoing dynamic fluoroscopy were subsequently found to have missed cervical spine injury. Conclusions With our protocol, 3 patients had significant cervical instability that would have been missed without dynamic fluoroscopy. Given the significant medical and legal ramifications of missed cervical spine injury and the benefits of early removal of cervical collars, more widespread use of dynamic fluoroscopy of the cervical spine is warranted.

KW - Cervical collar

KW - Cervical spine clearance

KW - Cervical spine fracture

KW - Dynamic fluoroscopy

KW - Flexion-extension views

UR - http://www.scopus.com/inward/record.url?scp=0038027519&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0038027519&partnerID=8YFLogxK

U2 - 10.1016/S0149-7944(00)00441-4

DO - 10.1016/S0149-7944(00)00441-4

M3 - Article

AN - SCOPUS:0038027519

VL - 58

SP - 96

EP - 100

JO - Journal of Surgical Education

JF - Journal of Surgical Education

SN - 1931-7204

IS - 1

ER -