Characterization of endoleaks by dynamic computed tomographic angiography

Jonas Rydberg, Stephen Lalka, Matthew Johnson, Dolores Cikrit, Michael Dalsing, Alan Sawchuk, Shoaib Shafique

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Current imaging modalities may not be able to detect endoleaks, differentiate between type II and type III, or localize inflow and outflow sources. We describe a new technique that can characterize endoleaks to guide secondary intervention. One hundred four patients with Zenith (Cook, Inc.) endograft repair of abdominal aortic aneurysms (AAAs) were monitored by serial computed tomographic angiography (CTA). Endoleaks were evaluated with a dynamic CTA using a stationary table position, 24-mm beam collimation, and continuous scanning over 30 to 40 seconds to create a cine. Twelve patients (12%) had endoleaks that persisted or appeared more than 30 days post-deployment. Five patients in whom the standard CT surveillance protocol could not differentiate type II versus type III endoleaks underwent dynamic CTA. This technique accurately characterized the endoleaks and localized inflow and outflow branches to guide the subsequent successful secondary interventions. Dynamic CTA is a useful technique to evaluate endoleaks for characterization and precise localization to guide secondary interventional therapy.

Original languageEnglish (US)
Pages (from-to)538-543
Number of pages6
JournalAmerican Journal of Surgery
Volume188
Issue number5
DOIs
StatePublished - Nov 2004
Externally publishedYes

Fingerprint

Endoleak
Angiography
Abdominal Aortic Aneurysm

Keywords

  • Computed tomography
  • Endoleaks
  • Endovascular aneurysm repair

ASJC Scopus subject areas

  • Surgery

Cite this

Characterization of endoleaks by dynamic computed tomographic angiography. / Rydberg, Jonas; Lalka, Stephen; Johnson, Matthew; Cikrit, Dolores; Dalsing, Michael; Sawchuk, Alan; Shafique, Shoaib.

In: American Journal of Surgery, Vol. 188, No. 5, 11.2004, p. 538-543.

Research output: Contribution to journalArticle

Rydberg, Jonas ; Lalka, Stephen ; Johnson, Matthew ; Cikrit, Dolores ; Dalsing, Michael ; Sawchuk, Alan ; Shafique, Shoaib. / Characterization of endoleaks by dynamic computed tomographic angiography. In: American Journal of Surgery. 2004 ; Vol. 188, No. 5. pp. 538-543.
@article{973b4423253646ab94dbcde996ce5ba5,
title = "Characterization of endoleaks by dynamic computed tomographic angiography",
abstract = "Current imaging modalities may not be able to detect endoleaks, differentiate between type II and type III, or localize inflow and outflow sources. We describe a new technique that can characterize endoleaks to guide secondary intervention. One hundred four patients with Zenith (Cook, Inc.) endograft repair of abdominal aortic aneurysms (AAAs) were monitored by serial computed tomographic angiography (CTA). Endoleaks were evaluated with a dynamic CTA using a stationary table position, 24-mm beam collimation, and continuous scanning over 30 to 40 seconds to create a cine. Twelve patients (12{\%}) had endoleaks that persisted or appeared more than 30 days post-deployment. Five patients in whom the standard CT surveillance protocol could not differentiate type II versus type III endoleaks underwent dynamic CTA. This technique accurately characterized the endoleaks and localized inflow and outflow branches to guide the subsequent successful secondary interventions. Dynamic CTA is a useful technique to evaluate endoleaks for characterization and precise localization to guide secondary interventional therapy.",
keywords = "Computed tomography, Endoleaks, Endovascular aneurysm repair",
author = "Jonas Rydberg and Stephen Lalka and Matthew Johnson and Dolores Cikrit and Michael Dalsing and Alan Sawchuk and Shoaib Shafique",
year = "2004",
month = "11",
doi = "10.1016/j.amjsurg.2004.07.011",
language = "English (US)",
volume = "188",
pages = "538--543",
journal = "American Journal of Surgery",
issn = "0002-9610",
publisher = "Elsevier Inc.",
number = "5",

}

TY - JOUR

T1 - Characterization of endoleaks by dynamic computed tomographic angiography

AU - Rydberg, Jonas

AU - Lalka, Stephen

AU - Johnson, Matthew

AU - Cikrit, Dolores

AU - Dalsing, Michael

AU - Sawchuk, Alan

AU - Shafique, Shoaib

PY - 2004/11

Y1 - 2004/11

N2 - Current imaging modalities may not be able to detect endoleaks, differentiate between type II and type III, or localize inflow and outflow sources. We describe a new technique that can characterize endoleaks to guide secondary intervention. One hundred four patients with Zenith (Cook, Inc.) endograft repair of abdominal aortic aneurysms (AAAs) were monitored by serial computed tomographic angiography (CTA). Endoleaks were evaluated with a dynamic CTA using a stationary table position, 24-mm beam collimation, and continuous scanning over 30 to 40 seconds to create a cine. Twelve patients (12%) had endoleaks that persisted or appeared more than 30 days post-deployment. Five patients in whom the standard CT surveillance protocol could not differentiate type II versus type III endoleaks underwent dynamic CTA. This technique accurately characterized the endoleaks and localized inflow and outflow branches to guide the subsequent successful secondary interventions. Dynamic CTA is a useful technique to evaluate endoleaks for characterization and precise localization to guide secondary interventional therapy.

AB - Current imaging modalities may not be able to detect endoleaks, differentiate between type II and type III, or localize inflow and outflow sources. We describe a new technique that can characterize endoleaks to guide secondary intervention. One hundred four patients with Zenith (Cook, Inc.) endograft repair of abdominal aortic aneurysms (AAAs) were monitored by serial computed tomographic angiography (CTA). Endoleaks were evaluated with a dynamic CTA using a stationary table position, 24-mm beam collimation, and continuous scanning over 30 to 40 seconds to create a cine. Twelve patients (12%) had endoleaks that persisted or appeared more than 30 days post-deployment. Five patients in whom the standard CT surveillance protocol could not differentiate type II versus type III endoleaks underwent dynamic CTA. This technique accurately characterized the endoleaks and localized inflow and outflow branches to guide the subsequent successful secondary interventions. Dynamic CTA is a useful technique to evaluate endoleaks for characterization and precise localization to guide secondary interventional therapy.

KW - Computed tomography

KW - Endoleaks

KW - Endovascular aneurysm repair

UR - http://www.scopus.com/inward/record.url?scp=8544246410&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=8544246410&partnerID=8YFLogxK

U2 - 10.1016/j.amjsurg.2004.07.011

DO - 10.1016/j.amjsurg.2004.07.011

M3 - Article

C2 - 15546566

AN - SCOPUS:8544246410

VL - 188

SP - 538

EP - 543

JO - American Journal of Surgery

JF - American Journal of Surgery

SN - 0002-9610

IS - 5

ER -