Abstract
The Single Use Y set is a disposable CAPD system that incorporates the use of a Quick Disconnect Clamp (QDC) for external occlusion. The system is designed using two types of twist lock connectology. The twist lock bag connector located at the distal end of the set is designed with a flange that provides a safety shelf for proper hand position during bag connection. The proximal patient connector on the Y set is a twist lock design requiring placement of povidone-iodine in the disinfectant chamber of the connector prior to patient connection. The Single Use Y is discarded after use.
Original language | English (US) |
---|---|
Pages (from-to) | 190-192 |
Number of pages | 3 |
Journal | Advances in peritoneal dialysis. Conference on Peritoneal Dialysis |
Volume | 7 |
State | Published - 1991 |
Externally published | Yes |
Fingerprint
ASJC Scopus subject areas
- Medicine(all)
Cite this
Clinical experiences with a single use Y bagless CAPD system applying a quick disconnect clamp for external occlusion. / Adcock, A.; Fox, K.; Jones, D.; Kenny, R.; Harbison, J.; Taber, Tim; Bloomfield, R.
In: Advances in peritoneal dialysis. Conference on Peritoneal Dialysis, Vol. 7, 1991, p. 190-192.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - Clinical experiences with a single use Y bagless CAPD system applying a quick disconnect clamp for external occlusion.
AU - Adcock, A.
AU - Fox, K.
AU - Jones, D.
AU - Kenny, R.
AU - Harbison, J.
AU - Taber, Tim
AU - Bloomfield, R.
PY - 1991
Y1 - 1991
N2 - The Single Use Y set is a disposable CAPD system that incorporates the use of a Quick Disconnect Clamp (QDC) for external occlusion. The system is designed using two types of twist lock connectology. The twist lock bag connector located at the distal end of the set is designed with a flange that provides a safety shelf for proper hand position during bag connection. The proximal patient connector on the Y set is a twist lock design requiring placement of povidone-iodine in the disinfectant chamber of the connector prior to patient connection. The Single Use Y is discarded after use.
AB - The Single Use Y set is a disposable CAPD system that incorporates the use of a Quick Disconnect Clamp (QDC) for external occlusion. The system is designed using two types of twist lock connectology. The twist lock bag connector located at the distal end of the set is designed with a flange that provides a safety shelf for proper hand position during bag connection. The proximal patient connector on the Y set is a twist lock design requiring placement of povidone-iodine in the disinfectant chamber of the connector prior to patient connection. The Single Use Y is discarded after use.
UR - http://www.scopus.com/inward/record.url?scp=0026086621&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0026086621&partnerID=8YFLogxK
M3 - Article
C2 - 1680423
AN - SCOPUS:0026086621
VL - 7
SP - 190
EP - 192
JO - Advances in peritoneal dialysis. Conference on Peritoneal Dialysis
JF - Advances in peritoneal dialysis. Conference on Peritoneal Dialysis
SN - 1197-8554
ER -