Closure of a very large patent ductus arteriosus using the Amplatzer Duct Occluder

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

A very large patent ductus arteriosus was closed completely using an Amplatzer Duct Occluder. This represents the largest patent ductus arteriosus to undergo closure with this endovascular technique.

Original languageEnglish
Pages (from-to)531-534
Number of pages4
JournalJournal of Invasive Cardiology
Volume14
Issue number9
StatePublished - Sep 2002

Fingerprint

Septal Occluder Device
Patent Ductus Arteriosus
Endovascular Procedures

Keywords

  • Amplatzer Duct Occluder
  • Device implantation
  • Patent ductus arteriosus
  • Transcatheter closure

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Closure of a very large patent ductus arteriosus using the Amplatzer Duct Occluder. / Hoyer, Mark.

In: Journal of Invasive Cardiology, Vol. 14, No. 9, 09.2002, p. 531-534.

Research output: Contribution to journalArticle

@article{f881641417e54dadb8d6e6be794df751,
title = "Closure of a very large patent ductus arteriosus using the Amplatzer Duct Occluder",
abstract = "A very large patent ductus arteriosus was closed completely using an Amplatzer Duct Occluder. This represents the largest patent ductus arteriosus to undergo closure with this endovascular technique.",
keywords = "Amplatzer Duct Occluder, Device implantation, Patent ductus arteriosus, Transcatheter closure",
author = "Mark Hoyer",
year = "2002",
month = "9",
language = "English",
volume = "14",
pages = "531--534",
journal = "Journal of Invasive Cardiology",
issn = "1042-3931",
publisher = "HMP Communications",
number = "9",

}

TY - JOUR

T1 - Closure of a very large patent ductus arteriosus using the Amplatzer Duct Occluder

AU - Hoyer, Mark

PY - 2002/9

Y1 - 2002/9

N2 - A very large patent ductus arteriosus was closed completely using an Amplatzer Duct Occluder. This represents the largest patent ductus arteriosus to undergo closure with this endovascular technique.

AB - A very large patent ductus arteriosus was closed completely using an Amplatzer Duct Occluder. This represents the largest patent ductus arteriosus to undergo closure with this endovascular technique.

KW - Amplatzer Duct Occluder

KW - Device implantation

KW - Patent ductus arteriosus

KW - Transcatheter closure

UR - http://www.scopus.com/inward/record.url?scp=0036738401&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036738401&partnerID=8YFLogxK

M3 - Article

VL - 14

SP - 531

EP - 534

JO - Journal of Invasive Cardiology

JF - Journal of Invasive Cardiology

SN - 1042-3931

IS - 9

ER -