Comparison of non-magnetic and magnetic beads multiplex assay for assessment of Plasmodium falciparum antibodies

Bartholomew N. Ondigo, Gregory S. Park, Cyrus Ayieko, Donald D. Nyangahu, Ronald Wasswa, Chandy John

Research output: Contribution to journalArticle

Abstract

Background. New reagents have emerged allowing researchers to assess a growing number of vaccine-associated immune parameters. Multiplex immunoassay(s) are emerging as efficient high-throughput assays in malaria serology. Currently, commercial vendors market several bead reagents for cytometric bead assays (CBA) but relative performances are not well published. We have compared two types of beadbased multiplex assays to measure relative antibody levels to malarial antigens. Methods. Assays for the measurement of antibodies to five Plasmodium falciparum vaccine candidates using non-magnetic and magnetic fluorescent microspheres were compared for their performances with a Bio-Plex200 instrument. Mean fluorescence intensity (MFI) was determined from individuals from western Kenya and compared to known positive and negative control plasma samples. Results. P. Falciparum recombinant antigens were successfully coupled to both nonmagnetic and magnetic beads in multiplex assays. MFIs between the two bead types were comparable for all antigens tested. Bead recovery was superior with magnetic beads for all antigens. MFI values of stored non-magnetic coupled beads did not differ from freshly coupled beads, though they showed higher levels of bead aggregation. Discussion. Magnetic and non-magnetic beads performed similarly in P. Falciparum antibody assays. Magnetic beads were more expensive, but had higher bead recovery, were more convenient to use, and provided rapid and easy protocol manipulation. Magnetic beads are a suitable alternative to non-magnetic beads in malarial antibody serology.

Original languageEnglish (US)
Article numbere6120
JournalPeerJ
Volume2019
Issue number1
DOIs
StatePublished - Jan 1 2019

Fingerprint

Plasmodium falciparum
Assays
Antigens
antibodies
Antibodies
assays
Serology
Vaccines
Fluorescence
antigens
Kenya
Microspheres
Immunoassay
fluorescence
vaccines
Malaria
recombinant antigens
Recovery
Research Personnel
immunoassays

Keywords

  • Bio-Plex
  • Magnetic
  • Multiplex
  • Non-magnetic
  • Plasmodium falciparum antigens

ASJC Scopus subject areas

  • Neuroscience(all)
  • Biochemistry, Genetics and Molecular Biology(all)
  • Agricultural and Biological Sciences(all)

Cite this

Comparison of non-magnetic and magnetic beads multiplex assay for assessment of Plasmodium falciparum antibodies. / Ondigo, Bartholomew N.; Park, Gregory S.; Ayieko, Cyrus; Nyangahu, Donald D.; Wasswa, Ronald; John, Chandy.

In: PeerJ, Vol. 2019, No. 1, e6120, 01.01.2019.

Research output: Contribution to journalArticle

Ondigo, Bartholomew N. ; Park, Gregory S. ; Ayieko, Cyrus ; Nyangahu, Donald D. ; Wasswa, Ronald ; John, Chandy. / Comparison of non-magnetic and magnetic beads multiplex assay for assessment of Plasmodium falciparum antibodies. In: PeerJ. 2019 ; Vol. 2019, No. 1.
@article{296ffc141c4046fcb79df5d5909b36a1,
title = "Comparison of non-magnetic and magnetic beads multiplex assay for assessment of Plasmodium falciparum antibodies",
abstract = "Background. New reagents have emerged allowing researchers to assess a growing number of vaccine-associated immune parameters. Multiplex immunoassay(s) are emerging as efficient high-throughput assays in malaria serology. Currently, commercial vendors market several bead reagents for cytometric bead assays (CBA) but relative performances are not well published. We have compared two types of beadbased multiplex assays to measure relative antibody levels to malarial antigens. Methods. Assays for the measurement of antibodies to five Plasmodium falciparum vaccine candidates using non-magnetic and magnetic fluorescent microspheres were compared for their performances with a Bio-Plex200 instrument. Mean fluorescence intensity (MFI) was determined from individuals from western Kenya and compared to known positive and negative control plasma samples. Results. P. Falciparum recombinant antigens were successfully coupled to both nonmagnetic and magnetic beads in multiplex assays. MFIs between the two bead types were comparable for all antigens tested. Bead recovery was superior with magnetic beads for all antigens. MFI values of stored non-magnetic coupled beads did not differ from freshly coupled beads, though they showed higher levels of bead aggregation. Discussion. Magnetic and non-magnetic beads performed similarly in P. Falciparum antibody assays. Magnetic beads were more expensive, but had higher bead recovery, were more convenient to use, and provided rapid and easy protocol manipulation. Magnetic beads are a suitable alternative to non-magnetic beads in malarial antibody serology.",
keywords = "Bio-Plex, Magnetic, Multiplex, Non-magnetic, Plasmodium falciparum antigens",
author = "Ondigo, {Bartholomew N.} and Park, {Gregory S.} and Cyrus Ayieko and Nyangahu, {Donald D.} and Ronald Wasswa and Chandy John",
year = "2019",
month = "1",
day = "1",
doi = "10.7717/peerj.6120",
language = "English (US)",
volume = "2019",
journal = "PeerJ",
issn = "2167-8359",
publisher = "PeerJ",
number = "1",

}

TY - JOUR

T1 - Comparison of non-magnetic and magnetic beads multiplex assay for assessment of Plasmodium falciparum antibodies

AU - Ondigo, Bartholomew N.

AU - Park, Gregory S.

AU - Ayieko, Cyrus

AU - Nyangahu, Donald D.

AU - Wasswa, Ronald

AU - John, Chandy

PY - 2019/1/1

Y1 - 2019/1/1

N2 - Background. New reagents have emerged allowing researchers to assess a growing number of vaccine-associated immune parameters. Multiplex immunoassay(s) are emerging as efficient high-throughput assays in malaria serology. Currently, commercial vendors market several bead reagents for cytometric bead assays (CBA) but relative performances are not well published. We have compared two types of beadbased multiplex assays to measure relative antibody levels to malarial antigens. Methods. Assays for the measurement of antibodies to five Plasmodium falciparum vaccine candidates using non-magnetic and magnetic fluorescent microspheres were compared for their performances with a Bio-Plex200 instrument. Mean fluorescence intensity (MFI) was determined from individuals from western Kenya and compared to known positive and negative control plasma samples. Results. P. Falciparum recombinant antigens were successfully coupled to both nonmagnetic and magnetic beads in multiplex assays. MFIs between the two bead types were comparable for all antigens tested. Bead recovery was superior with magnetic beads for all antigens. MFI values of stored non-magnetic coupled beads did not differ from freshly coupled beads, though they showed higher levels of bead aggregation. Discussion. Magnetic and non-magnetic beads performed similarly in P. Falciparum antibody assays. Magnetic beads were more expensive, but had higher bead recovery, were more convenient to use, and provided rapid and easy protocol manipulation. Magnetic beads are a suitable alternative to non-magnetic beads in malarial antibody serology.

AB - Background. New reagents have emerged allowing researchers to assess a growing number of vaccine-associated immune parameters. Multiplex immunoassay(s) are emerging as efficient high-throughput assays in malaria serology. Currently, commercial vendors market several bead reagents for cytometric bead assays (CBA) but relative performances are not well published. We have compared two types of beadbased multiplex assays to measure relative antibody levels to malarial antigens. Methods. Assays for the measurement of antibodies to five Plasmodium falciparum vaccine candidates using non-magnetic and magnetic fluorescent microspheres were compared for their performances with a Bio-Plex200 instrument. Mean fluorescence intensity (MFI) was determined from individuals from western Kenya and compared to known positive and negative control plasma samples. Results. P. Falciparum recombinant antigens were successfully coupled to both nonmagnetic and magnetic beads in multiplex assays. MFIs between the two bead types were comparable for all antigens tested. Bead recovery was superior with magnetic beads for all antigens. MFI values of stored non-magnetic coupled beads did not differ from freshly coupled beads, though they showed higher levels of bead aggregation. Discussion. Magnetic and non-magnetic beads performed similarly in P. Falciparum antibody assays. Magnetic beads were more expensive, but had higher bead recovery, were more convenient to use, and provided rapid and easy protocol manipulation. Magnetic beads are a suitable alternative to non-magnetic beads in malarial antibody serology.

KW - Bio-Plex

KW - Magnetic

KW - Multiplex

KW - Non-magnetic

KW - Plasmodium falciparum antigens

UR - http://www.scopus.com/inward/record.url?scp=85059636179&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85059636179&partnerID=8YFLogxK

U2 - 10.7717/peerj.6120

DO - 10.7717/peerj.6120

M3 - Article

VL - 2019

JO - PeerJ

JF - PeerJ

SN - 2167-8359

IS - 1

M1 - e6120

ER -