An analytic model to calculate dose distributions in regions containing beta sources is developed along with a solution for the dose distribution in an infinite, homogeneous medium in which there is a uniform, monoenergetic, isotropic source distribution on only one side of a plane. Comparisons with published Monte Carlo calculations are made.

Original languageEnglish (US)
Pages (from-to)797-806
Number of pages10
JournalMedical Physics
Volume14
Issue number5
DOIs
StatePublished - 1987
Externally publishedYes

ASJC Scopus subject areas

  • Biophysics

Cite this

Dose distributions in regions containing beta sources : Plane interface in a homogeneous medium. / Werner, B. L.; Das, I. J.

In: Medical Physics, Vol. 14, No. 5, 1987, p. 797-806.

Research output: Contribution to journalArticle

@article{3b619bbf1b2b4e6dab8dbd191b5e96bb,
title = "Dose distributions in regions containing beta sources: Plane interface in a homogeneous medium",
abstract = "An analytic model to calculate dose distributions in regions containing beta sources is developed along with a solution for the dose distribution in an infinite, homogeneous medium in which there is a uniform, monoenergetic, isotropic source distribution on only one side of a plane. Comparisons with published Monte Carlo calculations are made.",
author = "Werner, {B. L.} and Das, {I. J.}",
year = "1987",
doi = "10.1118/1.596005",
language = "English (US)",
volume = "14",
pages = "797--806",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "5",

}

TY - JOUR

T1 - Dose distributions in regions containing beta sources

T2 - Plane interface in a homogeneous medium

AU - Werner, B. L.

AU - Das, I. J.

PY - 1987

Y1 - 1987

N2 - An analytic model to calculate dose distributions in regions containing beta sources is developed along with a solution for the dose distribution in an infinite, homogeneous medium in which there is a uniform, monoenergetic, isotropic source distribution on only one side of a plane. Comparisons with published Monte Carlo calculations are made.

AB - An analytic model to calculate dose distributions in regions containing beta sources is developed along with a solution for the dose distribution in an infinite, homogeneous medium in which there is a uniform, monoenergetic, isotropic source distribution on only one side of a plane. Comparisons with published Monte Carlo calculations are made.

UR - http://www.scopus.com/inward/record.url?scp=0023611611&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023611611&partnerID=8YFLogxK

U2 - 10.1118/1.596005

DO - 10.1118/1.596005

M3 - Article

VL - 14

SP - 797

EP - 806

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 5

ER -