Dosimetry of very high energy electrons (VHEE) for radiotherapy applications

Using radiochromic film measurements and Monte Carlo simulations

A. Subiel, V. Moskvin, G. H. Welsh, S. Cipiccia, D. Reboredo, P. Evans, M. Partridge, Colleen DesRosiers, M. P. Anania, A. Cianchi, A. Mostacci, E. Chiadroni, D. Di Giovenale, F. Villa, R. Pompili, M. Ferrario, M. Belleveglia, G. Di Pirro, G. Gatti, C. Vaccarezza & 10 others B. Seitz, R. C. Isaac, E. Brunetti, S. M. Wiggins, B. Ersfeld, M. R. Islam, Marc Mendonca, A. Sorensen, M. Boyd, D. A. Jaroszynski

Research output: Contribution to journalArticle

10 Citations (Scopus)

Abstract

Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic® film. Calibration of the film has been carried out for beams of two different energy ranges: 20 MeV and 165 MeV from conventional radio frequency linear accelerators. In addition, EBT2 film has been used for dose measurements with 135 MeV electron beams produced by a laser-plasma wakefield accelerator. The dose response measurements and percentage depth dose profiles have been compared with calculations carried out using the general-purpose FLUKA Monte Carlo (MC) radiation transport code. The impact of induced radioactivity on film response for VHEEs has been evaluated using the MC simulations. A neutron yield of the order of 10-5 neutrons cm-2 per incident electron has been estimated and induced activity due to radionuclide production is found to have a negligible effect on total dose deposition and film response. Neutron and proton contribution to the equivalent doses are negligible for VHEE. The study demonstrates that EBT2 Gafchromic film is a reliable dosimeter that can be used for dosimetry of VHEE. The results indicate an energy-independent response of the dosimeter for 20 MeV and 165 MeV electron beams and has been found to be suitable for dosimetry of VHEE.

Original languageEnglish
Article number5811
Pages (from-to)5811-5829
Number of pages19
JournalPhysics in Medicine and Biology
Volume59
Issue number19
DOIs
StatePublished - Oct 7 2014

Fingerprint

High-Energy Radiotherapy
Electrons
Neutrons
Particle Accelerators
Radio
Photons
Radioisotopes
Radioactivity
Calibration
Protons
Lasers
Radiotherapy
Radiation

Keywords

  • EBT2
  • film dosimetry
  • Monte Carlo
  • very high energy electrons

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Dosimetry of very high energy electrons (VHEE) for radiotherapy applications : Using radiochromic film measurements and Monte Carlo simulations. / Subiel, A.; Moskvin, V.; Welsh, G. H.; Cipiccia, S.; Reboredo, D.; Evans, P.; Partridge, M.; DesRosiers, Colleen; Anania, M. P.; Cianchi, A.; Mostacci, A.; Chiadroni, E.; Di Giovenale, D.; Villa, F.; Pompili, R.; Ferrario, M.; Belleveglia, M.; Di Pirro, G.; Gatti, G.; Vaccarezza, C.; Seitz, B.; Isaac, R. C.; Brunetti, E.; Wiggins, S. M.; Ersfeld, B.; Islam, M. R.; Mendonca, Marc; Sorensen, A.; Boyd, M.; Jaroszynski, D. A.

In: Physics in Medicine and Biology, Vol. 59, No. 19, 5811, 07.10.2014, p. 5811-5829.

Research output: Contribution to journalArticle

Subiel, A, Moskvin, V, Welsh, GH, Cipiccia, S, Reboredo, D, Evans, P, Partridge, M, DesRosiers, C, Anania, MP, Cianchi, A, Mostacci, A, Chiadroni, E, Di Giovenale, D, Villa, F, Pompili, R, Ferrario, M, Belleveglia, M, Di Pirro, G, Gatti, G, Vaccarezza, C, Seitz, B, Isaac, RC, Brunetti, E, Wiggins, SM, Ersfeld, B, Islam, MR, Mendonca, M, Sorensen, A, Boyd, M & Jaroszynski, DA 2014, 'Dosimetry of very high energy electrons (VHEE) for radiotherapy applications: Using radiochromic film measurements and Monte Carlo simulations', Physics in Medicine and Biology, vol. 59, no. 19, 5811, pp. 5811-5829. https://doi.org/10.1088/0031-9155/59/19/5811
Subiel, A. ; Moskvin, V. ; Welsh, G. H. ; Cipiccia, S. ; Reboredo, D. ; Evans, P. ; Partridge, M. ; DesRosiers, Colleen ; Anania, M. P. ; Cianchi, A. ; Mostacci, A. ; Chiadroni, E. ; Di Giovenale, D. ; Villa, F. ; Pompili, R. ; Ferrario, M. ; Belleveglia, M. ; Di Pirro, G. ; Gatti, G. ; Vaccarezza, C. ; Seitz, B. ; Isaac, R. C. ; Brunetti, E. ; Wiggins, S. M. ; Ersfeld, B. ; Islam, M. R. ; Mendonca, Marc ; Sorensen, A. ; Boyd, M. ; Jaroszynski, D. A. / Dosimetry of very high energy electrons (VHEE) for radiotherapy applications : Using radiochromic film measurements and Monte Carlo simulations. In: Physics in Medicine and Biology. 2014 ; Vol. 59, No. 19. pp. 5811-5829.
@article{ca7df33137f5405fb33b3c3a4418fd24,
title = "Dosimetry of very high energy electrons (VHEE) for radiotherapy applications: Using radiochromic film measurements and Monte Carlo simulations",
abstract = "Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic{\circledR} film. Calibration of the film has been carried out for beams of two different energy ranges: 20 MeV and 165 MeV from conventional radio frequency linear accelerators. In addition, EBT2 film has been used for dose measurements with 135 MeV electron beams produced by a laser-plasma wakefield accelerator. The dose response measurements and percentage depth dose profiles have been compared with calculations carried out using the general-purpose FLUKA Monte Carlo (MC) radiation transport code. The impact of induced radioactivity on film response for VHEEs has been evaluated using the MC simulations. A neutron yield of the order of 10-5 neutrons cm-2 per incident electron has been estimated and induced activity due to radionuclide production is found to have a negligible effect on total dose deposition and film response. Neutron and proton contribution to the equivalent doses are negligible for VHEE. The study demonstrates that EBT2 Gafchromic film is a reliable dosimeter that can be used for dosimetry of VHEE. The results indicate an energy-independent response of the dosimeter for 20 MeV and 165 MeV electron beams and has been found to be suitable for dosimetry of VHEE.",
keywords = "EBT2, film dosimetry, Monte Carlo, very high energy electrons",
author = "A. Subiel and V. Moskvin and Welsh, {G. H.} and S. Cipiccia and D. Reboredo and P. Evans and M. Partridge and Colleen DesRosiers and Anania, {M. P.} and A. Cianchi and A. Mostacci and E. Chiadroni and {Di Giovenale}, D. and F. Villa and R. Pompili and M. Ferrario and M. Belleveglia and {Di Pirro}, G. and G. Gatti and C. Vaccarezza and B. Seitz and Isaac, {R. C.} and E. Brunetti and Wiggins, {S. M.} and B. Ersfeld and Islam, {M. R.} and Marc Mendonca and A. Sorensen and M. Boyd and Jaroszynski, {D. A.}",
year = "2014",
month = "10",
day = "7",
doi = "10.1088/0031-9155/59/19/5811",
language = "English",
volume = "59",
pages = "5811--5829",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "19",

}

TY - JOUR

T1 - Dosimetry of very high energy electrons (VHEE) for radiotherapy applications

T2 - Using radiochromic film measurements and Monte Carlo simulations

AU - Subiel, A.

AU - Moskvin, V.

AU - Welsh, G. H.

AU - Cipiccia, S.

AU - Reboredo, D.

AU - Evans, P.

AU - Partridge, M.

AU - DesRosiers, Colleen

AU - Anania, M. P.

AU - Cianchi, A.

AU - Mostacci, A.

AU - Chiadroni, E.

AU - Di Giovenale, D.

AU - Villa, F.

AU - Pompili, R.

AU - Ferrario, M.

AU - Belleveglia, M.

AU - Di Pirro, G.

AU - Gatti, G.

AU - Vaccarezza, C.

AU - Seitz, B.

AU - Isaac, R. C.

AU - Brunetti, E.

AU - Wiggins, S. M.

AU - Ersfeld, B.

AU - Islam, M. R.

AU - Mendonca, Marc

AU - Sorensen, A.

AU - Boyd, M.

AU - Jaroszynski, D. A.

PY - 2014/10/7

Y1 - 2014/10/7

N2 - Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic® film. Calibration of the film has been carried out for beams of two different energy ranges: 20 MeV and 165 MeV from conventional radio frequency linear accelerators. In addition, EBT2 film has been used for dose measurements with 135 MeV electron beams produced by a laser-plasma wakefield accelerator. The dose response measurements and percentage depth dose profiles have been compared with calculations carried out using the general-purpose FLUKA Monte Carlo (MC) radiation transport code. The impact of induced radioactivity on film response for VHEEs has been evaluated using the MC simulations. A neutron yield of the order of 10-5 neutrons cm-2 per incident electron has been estimated and induced activity due to radionuclide production is found to have a negligible effect on total dose deposition and film response. Neutron and proton contribution to the equivalent doses are negligible for VHEE. The study demonstrates that EBT2 Gafchromic film is a reliable dosimeter that can be used for dosimetry of VHEE. The results indicate an energy-independent response of the dosimeter for 20 MeV and 165 MeV electron beams and has been found to be suitable for dosimetry of VHEE.

AB - Very high energy electrons (VHEE) in the range from 100-250 MeV have the potential of becoming an alternative modality in radiotherapy because of their improved dosimetry properties compared with MV photons from contemporary medical linear accelerators. Due to the need for accurate dosimetry of small field size VHEE beams we have performed dose measurements using EBT2 Gafchromic® film. Calibration of the film has been carried out for beams of two different energy ranges: 20 MeV and 165 MeV from conventional radio frequency linear accelerators. In addition, EBT2 film has been used for dose measurements with 135 MeV electron beams produced by a laser-plasma wakefield accelerator. The dose response measurements and percentage depth dose profiles have been compared with calculations carried out using the general-purpose FLUKA Monte Carlo (MC) radiation transport code. The impact of induced radioactivity on film response for VHEEs has been evaluated using the MC simulations. A neutron yield of the order of 10-5 neutrons cm-2 per incident electron has been estimated and induced activity due to radionuclide production is found to have a negligible effect on total dose deposition and film response. Neutron and proton contribution to the equivalent doses are negligible for VHEE. The study demonstrates that EBT2 Gafchromic film is a reliable dosimeter that can be used for dosimetry of VHEE. The results indicate an energy-independent response of the dosimeter for 20 MeV and 165 MeV electron beams and has been found to be suitable for dosimetry of VHEE.

KW - EBT2

KW - film dosimetry

KW - Monte Carlo

KW - very high energy electrons

UR - http://www.scopus.com/inward/record.url?scp=84907210236&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84907210236&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/59/19/5811

DO - 10.1088/0031-9155/59/19/5811

M3 - Article

VL - 59

SP - 5811

EP - 5829

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 19

M1 - 5811

ER -