Elastic properties of the respiratory system in infants with cystic fibrosis

Robert Tepper, Andrea Weist, Tamica Williams-Nkomo, Jeffrey Kisling

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Respiratory system compliance (Crs) in infants with cystic fibrosis (CF) has been reported as decreased or not different compared with healthy control subjects; however, the reported measurements of Crs were "quasi- static" or by the single-breath occlusion technique, with all measurements limited to tidal lung volume, as well as using inspiratory rather than expiratory pressures. We compared the passive elastic properties of the respiratory system of sleeping infants with CF (n = 10) and healthy control subjects (n = 34) by measuring static deflation pressure-volume (PV) curves from a lung volume at 30 cm H2O (V30) to FRC. There was no significant difference between the groups for Crs, which was measured as the slope between airway relaxation pressures of 5 and 15 cm H2O, the linear portion of the deflation PV curve. In addition, when PV curves were normalized to V30, there were no differences between the infants with CF and healthy control subjects in the fractional volumes at any airway pressure. The infants with CF had significantly lower forced expiratory flows; however, lower flows did not correlate with fractional volumes measured from the PV curve. Our findings indicate that infants with CF have normal elastic properties of the respiratory system.

Original languageEnglish
Pages (from-to)505-507
Number of pages3
JournalAmerican Journal of Respiratory and Critical Care Medicine
Volume170
Issue number5
DOIs
StatePublished - Sep 1 2004

Fingerprint

Cystic Fibrosis
Respiratory System
Pressure
Healthy Volunteers
Lung
Tidal Volume
Compliance

Keywords

  • Compliance
  • Pressure-volume curves

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine

Cite this

Elastic properties of the respiratory system in infants with cystic fibrosis. / Tepper, Robert; Weist, Andrea; Williams-Nkomo, Tamica; Kisling, Jeffrey.

In: American Journal of Respiratory and Critical Care Medicine, Vol. 170, No. 5, 01.09.2004, p. 505-507.

Research output: Contribution to journalArticle

Tepper, Robert ; Weist, Andrea ; Williams-Nkomo, Tamica ; Kisling, Jeffrey. / Elastic properties of the respiratory system in infants with cystic fibrosis. In: American Journal of Respiratory and Critical Care Medicine. 2004 ; Vol. 170, No. 5. pp. 505-507.
@article{18cff5e15c9e4613822f6675a3ee4d12,
title = "Elastic properties of the respiratory system in infants with cystic fibrosis",
abstract = "Respiratory system compliance (Crs) in infants with cystic fibrosis (CF) has been reported as decreased or not different compared with healthy control subjects; however, the reported measurements of Crs were {"}quasi- static{"} or by the single-breath occlusion technique, with all measurements limited to tidal lung volume, as well as using inspiratory rather than expiratory pressures. We compared the passive elastic properties of the respiratory system of sleeping infants with CF (n = 10) and healthy control subjects (n = 34) by measuring static deflation pressure-volume (PV) curves from a lung volume at 30 cm H2O (V30) to FRC. There was no significant difference between the groups for Crs, which was measured as the slope between airway relaxation pressures of 5 and 15 cm H2O, the linear portion of the deflation PV curve. In addition, when PV curves were normalized to V30, there were no differences between the infants with CF and healthy control subjects in the fractional volumes at any airway pressure. The infants with CF had significantly lower forced expiratory flows; however, lower flows did not correlate with fractional volumes measured from the PV curve. Our findings indicate that infants with CF have normal elastic properties of the respiratory system.",
keywords = "Compliance, Pressure-volume curves",
author = "Robert Tepper and Andrea Weist and Tamica Williams-Nkomo and Jeffrey Kisling",
year = "2004",
month = "9",
day = "1",
doi = "10.1164/rccm.200401-132OC",
language = "English",
volume = "170",
pages = "505--507",
journal = "American Journal of Respiratory and Critical Care Medicine",
issn = "1073-449X",
publisher = "American Thoracic Society",
number = "5",

}

TY - JOUR

T1 - Elastic properties of the respiratory system in infants with cystic fibrosis

AU - Tepper, Robert

AU - Weist, Andrea

AU - Williams-Nkomo, Tamica

AU - Kisling, Jeffrey

PY - 2004/9/1

Y1 - 2004/9/1

N2 - Respiratory system compliance (Crs) in infants with cystic fibrosis (CF) has been reported as decreased or not different compared with healthy control subjects; however, the reported measurements of Crs were "quasi- static" or by the single-breath occlusion technique, with all measurements limited to tidal lung volume, as well as using inspiratory rather than expiratory pressures. We compared the passive elastic properties of the respiratory system of sleeping infants with CF (n = 10) and healthy control subjects (n = 34) by measuring static deflation pressure-volume (PV) curves from a lung volume at 30 cm H2O (V30) to FRC. There was no significant difference between the groups for Crs, which was measured as the slope between airway relaxation pressures of 5 and 15 cm H2O, the linear portion of the deflation PV curve. In addition, when PV curves were normalized to V30, there were no differences between the infants with CF and healthy control subjects in the fractional volumes at any airway pressure. The infants with CF had significantly lower forced expiratory flows; however, lower flows did not correlate with fractional volumes measured from the PV curve. Our findings indicate that infants with CF have normal elastic properties of the respiratory system.

AB - Respiratory system compliance (Crs) in infants with cystic fibrosis (CF) has been reported as decreased or not different compared with healthy control subjects; however, the reported measurements of Crs were "quasi- static" or by the single-breath occlusion technique, with all measurements limited to tidal lung volume, as well as using inspiratory rather than expiratory pressures. We compared the passive elastic properties of the respiratory system of sleeping infants with CF (n = 10) and healthy control subjects (n = 34) by measuring static deflation pressure-volume (PV) curves from a lung volume at 30 cm H2O (V30) to FRC. There was no significant difference between the groups for Crs, which was measured as the slope between airway relaxation pressures of 5 and 15 cm H2O, the linear portion of the deflation PV curve. In addition, when PV curves were normalized to V30, there were no differences between the infants with CF and healthy control subjects in the fractional volumes at any airway pressure. The infants with CF had significantly lower forced expiratory flows; however, lower flows did not correlate with fractional volumes measured from the PV curve. Our findings indicate that infants with CF have normal elastic properties of the respiratory system.

KW - Compliance

KW - Pressure-volume curves

UR - http://www.scopus.com/inward/record.url?scp=4444300853&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=4444300853&partnerID=8YFLogxK

U2 - 10.1164/rccm.200401-132OC

DO - 10.1164/rccm.200401-132OC

M3 - Article

C2 - 15172890

AN - SCOPUS:4444300853

VL - 170

SP - 505

EP - 507

JO - American Journal of Respiratory and Critical Care Medicine

JF - American Journal of Respiratory and Critical Care Medicine

SN - 1073-449X

IS - 5

ER -