Endocardial detection of repolarization alternans.

David J. Christini, Kenneth M. Stein, Steven C. Hao, Steven M. Markowitz, Suneet Mittal, David J. Slotwiner, Sei Iwai, Mithilesh Das, Bruce B. Lerman

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

Repolarization alternans (RPA) is prognostic of sudden cardiac death and is thought to be mechanistically linked to the initiation of ventricular tachyarrhythmias. Thus, implantable cardiac device detection of RPA may be therapeutically valuable. Because alternans detection is currently limited to surface electrocardiograms, we investigated whether RPA could be measured using a single right-ventricular endocardial lead in humans. Such a location was chosen because it is consistent with the requirements for long-term implantable-device implementation. During diagnostic electrophysiological testing, 28 patients (23 male, 5 female; 61 +/- 15 years) were evaluated for surface T-wave alternans (TWA; the current "gold standard" for RPA detection) and endocardial RPA during 5 min of 550-ms right-atrial pacing. Power spectral analysis indicated that 11/28 patients had both surface TWA and endocardial RPA, 9/28 patients had neither, and 8/28 patients had discordant results (71% concordance; p = 0.02). Importantly, unlike surface TWA, endocardial RPA was detectable on a beat-to-beat basis. Given the putative mechanistic link between RPA and ventricular arrhythmias, beat-to-beat endocardial RPA detection might be of diagnostic or therapeutic utility.

Original languageEnglish (US)
Pages (from-to)855-862
Number of pages8
JournalIEEE Transactions on Biomedical Engineering
Volume50
Issue number7
StatePublished - Jul 2003
Externally publishedYes

Fingerprint

Electrocardiography
Spectrum analysis
Lead
Testing

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Christini, D. J., Stein, K. M., Hao, S. C., Markowitz, S. M., Mittal, S., Slotwiner, D. J., ... Lerman, B. B. (2003). Endocardial detection of repolarization alternans. IEEE Transactions on Biomedical Engineering, 50(7), 855-862.

Endocardial detection of repolarization alternans. / Christini, David J.; Stein, Kenneth M.; Hao, Steven C.; Markowitz, Steven M.; Mittal, Suneet; Slotwiner, David J.; Iwai, Sei; Das, Mithilesh; Lerman, Bruce B.

In: IEEE Transactions on Biomedical Engineering, Vol. 50, No. 7, 07.2003, p. 855-862.

Research output: Contribution to journalArticle

Christini, DJ, Stein, KM, Hao, SC, Markowitz, SM, Mittal, S, Slotwiner, DJ, Iwai, S, Das, M & Lerman, BB 2003, 'Endocardial detection of repolarization alternans.', IEEE Transactions on Biomedical Engineering, vol. 50, no. 7, pp. 855-862.
Christini DJ, Stein KM, Hao SC, Markowitz SM, Mittal S, Slotwiner DJ et al. Endocardial detection of repolarization alternans. IEEE Transactions on Biomedical Engineering. 2003 Jul;50(7):855-862.
Christini, David J. ; Stein, Kenneth M. ; Hao, Steven C. ; Markowitz, Steven M. ; Mittal, Suneet ; Slotwiner, David J. ; Iwai, Sei ; Das, Mithilesh ; Lerman, Bruce B. / Endocardial detection of repolarization alternans. In: IEEE Transactions on Biomedical Engineering. 2003 ; Vol. 50, No. 7. pp. 855-862.
@article{8e75a17a5583437cb8163690f9dea8eb,
title = "Endocardial detection of repolarization alternans.",
abstract = "Repolarization alternans (RPA) is prognostic of sudden cardiac death and is thought to be mechanistically linked to the initiation of ventricular tachyarrhythmias. Thus, implantable cardiac device detection of RPA may be therapeutically valuable. Because alternans detection is currently limited to surface electrocardiograms, we investigated whether RPA could be measured using a single right-ventricular endocardial lead in humans. Such a location was chosen because it is consistent with the requirements for long-term implantable-device implementation. During diagnostic electrophysiological testing, 28 patients (23 male, 5 female; 61 +/- 15 years) were evaluated for surface T-wave alternans (TWA; the current {"}gold standard{"} for RPA detection) and endocardial RPA during 5 min of 550-ms right-atrial pacing. Power spectral analysis indicated that 11/28 patients had both surface TWA and endocardial RPA, 9/28 patients had neither, and 8/28 patients had discordant results (71{\%} concordance; p = 0.02). Importantly, unlike surface TWA, endocardial RPA was detectable on a beat-to-beat basis. Given the putative mechanistic link between RPA and ventricular arrhythmias, beat-to-beat endocardial RPA detection might be of diagnostic or therapeutic utility.",
author = "Christini, {David J.} and Stein, {Kenneth M.} and Hao, {Steven C.} and Markowitz, {Steven M.} and Suneet Mittal and Slotwiner, {David J.} and Sei Iwai and Mithilesh Das and Lerman, {Bruce B.}",
year = "2003",
month = "7",
language = "English (US)",
volume = "50",
pages = "855--862",
journal = "IEEE Transactions on Biomedical Engineering",
issn = "0018-9294",
publisher = "IEEE Computer Society",
number = "7",

}

TY - JOUR

T1 - Endocardial detection of repolarization alternans.

AU - Christini, David J.

AU - Stein, Kenneth M.

AU - Hao, Steven C.

AU - Markowitz, Steven M.

AU - Mittal, Suneet

AU - Slotwiner, David J.

AU - Iwai, Sei

AU - Das, Mithilesh

AU - Lerman, Bruce B.

PY - 2003/7

Y1 - 2003/7

N2 - Repolarization alternans (RPA) is prognostic of sudden cardiac death and is thought to be mechanistically linked to the initiation of ventricular tachyarrhythmias. Thus, implantable cardiac device detection of RPA may be therapeutically valuable. Because alternans detection is currently limited to surface electrocardiograms, we investigated whether RPA could be measured using a single right-ventricular endocardial lead in humans. Such a location was chosen because it is consistent with the requirements for long-term implantable-device implementation. During diagnostic electrophysiological testing, 28 patients (23 male, 5 female; 61 +/- 15 years) were evaluated for surface T-wave alternans (TWA; the current "gold standard" for RPA detection) and endocardial RPA during 5 min of 550-ms right-atrial pacing. Power spectral analysis indicated that 11/28 patients had both surface TWA and endocardial RPA, 9/28 patients had neither, and 8/28 patients had discordant results (71% concordance; p = 0.02). Importantly, unlike surface TWA, endocardial RPA was detectable on a beat-to-beat basis. Given the putative mechanistic link between RPA and ventricular arrhythmias, beat-to-beat endocardial RPA detection might be of diagnostic or therapeutic utility.

AB - Repolarization alternans (RPA) is prognostic of sudden cardiac death and is thought to be mechanistically linked to the initiation of ventricular tachyarrhythmias. Thus, implantable cardiac device detection of RPA may be therapeutically valuable. Because alternans detection is currently limited to surface electrocardiograms, we investigated whether RPA could be measured using a single right-ventricular endocardial lead in humans. Such a location was chosen because it is consistent with the requirements for long-term implantable-device implementation. During diagnostic electrophysiological testing, 28 patients (23 male, 5 female; 61 +/- 15 years) were evaluated for surface T-wave alternans (TWA; the current "gold standard" for RPA detection) and endocardial RPA during 5 min of 550-ms right-atrial pacing. Power spectral analysis indicated that 11/28 patients had both surface TWA and endocardial RPA, 9/28 patients had neither, and 8/28 patients had discordant results (71% concordance; p = 0.02). Importantly, unlike surface TWA, endocardial RPA was detectable on a beat-to-beat basis. Given the putative mechanistic link between RPA and ventricular arrhythmias, beat-to-beat endocardial RPA detection might be of diagnostic or therapeutic utility.

UR - http://www.scopus.com/inward/record.url?scp=0042664119&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0042664119&partnerID=8YFLogxK

M3 - Article

C2 - 12848353

AN - SCOPUS:0042664119

VL - 50

SP - 855

EP - 862

JO - IEEE Transactions on Biomedical Engineering

JF - IEEE Transactions on Biomedical Engineering

SN - 0018-9294

IS - 7

ER -