Abstract

Rationale and Objectives: The aim of this study was to evaluate a new thick-needle phosphor plate for computed radiography. Materials and Methods: Two studies were performed. Patients acted as their own controls. In the first study, old powder and new needle phosphor plate technologies were compared. Twenty infants were identified who had undergone chest x-rays with both systems within 3 days of each other. Exposure factors were constant. In the second study, standard and reduced exposure techniques (tube current-time product reduced by 20%) using the needle phosphor technology were compared. Twenty babies who had been imaged with both standard and reduced exposures within 3 days of each other were evaluated. Results: There was a significant preference for images obtained with the new needle phosphor technology compared with the older powder technology (P < 01). Using the new needle phosphor plates, a dose reduction of 20% could be achieved without a significant detectable difference between the high-dose and low-dose images (P < 19). Conclusions: For the study comparing old and new phosphor plate technology at fixed exposure, images were better with the new technology. Using the new plate technology, dose can be decreased by ≥20%.

Original languageEnglish
Pages (from-to)197-198
Number of pages2
JournalAcademic Radiology
Volume18
Issue number2
DOIs
StatePublished - Feb 2011

Fingerprint

Thorax
Technology
Needles
Powders
Radiography
X-Rays

Keywords

  • Computed radiography
  • Neonatal chest imaging
  • Radiation dose

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Evaluation of a New Phosphor Plate Technology for Neonatal Portable Chest Radiographs. / Cohen, Mervyn; Corea, Donald; Wanner, Matthew; Karmazyn, Boaz; Gunderman, Richard; Applegate, Kimberly; Jennings, Samuel G.

In: Academic Radiology, Vol. 18, No. 2, 02.2011, p. 197-198.

Research output: Contribution to journalArticle

Cohen, Mervyn ; Corea, Donald ; Wanner, Matthew ; Karmazyn, Boaz ; Gunderman, Richard ; Applegate, Kimberly ; Jennings, Samuel G. / Evaluation of a New Phosphor Plate Technology for Neonatal Portable Chest Radiographs. In: Academic Radiology. 2011 ; Vol. 18, No. 2. pp. 197-198.
@article{d3d228e5a623468585e36fbb2c16ced7,
title = "Evaluation of a New Phosphor Plate Technology for Neonatal Portable Chest Radiographs",
abstract = "Rationale and Objectives: The aim of this study was to evaluate a new thick-needle phosphor plate for computed radiography. Materials and Methods: Two studies were performed. Patients acted as their own controls. In the first study, old powder and new needle phosphor plate technologies were compared. Twenty infants were identified who had undergone chest x-rays with both systems within 3 days of each other. Exposure factors were constant. In the second study, standard and reduced exposure techniques (tube current-time product reduced by 20{\%}) using the needle phosphor technology were compared. Twenty babies who had been imaged with both standard and reduced exposures within 3 days of each other were evaluated. Results: There was a significant preference for images obtained with the new needle phosphor technology compared with the older powder technology (P < 01). Using the new needle phosphor plates, a dose reduction of 20{\%} could be achieved without a significant detectable difference between the high-dose and low-dose images (P < 19). Conclusions: For the study comparing old and new phosphor plate technology at fixed exposure, images were better with the new technology. Using the new plate technology, dose can be decreased by ≥20{\%}.",
keywords = "Computed radiography, Neonatal chest imaging, Radiation dose",
author = "Mervyn Cohen and Donald Corea and Matthew Wanner and Boaz Karmazyn and Richard Gunderman and Kimberly Applegate and Jennings, {Samuel G.}",
year = "2011",
month = "2",
doi = "10.1016/j.acra.2010.09.015",
language = "English",
volume = "18",
pages = "197--198",
journal = "Academic Radiology",
issn = "1076-6332",
publisher = "Elsevier USA",
number = "2",

}

TY - JOUR

T1 - Evaluation of a New Phosphor Plate Technology for Neonatal Portable Chest Radiographs

AU - Cohen, Mervyn

AU - Corea, Donald

AU - Wanner, Matthew

AU - Karmazyn, Boaz

AU - Gunderman, Richard

AU - Applegate, Kimberly

AU - Jennings, Samuel G.

PY - 2011/2

Y1 - 2011/2

N2 - Rationale and Objectives: The aim of this study was to evaluate a new thick-needle phosphor plate for computed radiography. Materials and Methods: Two studies were performed. Patients acted as their own controls. In the first study, old powder and new needle phosphor plate technologies were compared. Twenty infants were identified who had undergone chest x-rays with both systems within 3 days of each other. Exposure factors were constant. In the second study, standard and reduced exposure techniques (tube current-time product reduced by 20%) using the needle phosphor technology were compared. Twenty babies who had been imaged with both standard and reduced exposures within 3 days of each other were evaluated. Results: There was a significant preference for images obtained with the new needle phosphor technology compared with the older powder technology (P < 01). Using the new needle phosphor plates, a dose reduction of 20% could be achieved without a significant detectable difference between the high-dose and low-dose images (P < 19). Conclusions: For the study comparing old and new phosphor plate technology at fixed exposure, images were better with the new technology. Using the new plate technology, dose can be decreased by ≥20%.

AB - Rationale and Objectives: The aim of this study was to evaluate a new thick-needle phosphor plate for computed radiography. Materials and Methods: Two studies were performed. Patients acted as their own controls. In the first study, old powder and new needle phosphor plate technologies were compared. Twenty infants were identified who had undergone chest x-rays with both systems within 3 days of each other. Exposure factors were constant. In the second study, standard and reduced exposure techniques (tube current-time product reduced by 20%) using the needle phosphor technology were compared. Twenty babies who had been imaged with both standard and reduced exposures within 3 days of each other were evaluated. Results: There was a significant preference for images obtained with the new needle phosphor technology compared with the older powder technology (P < 01). Using the new needle phosphor plates, a dose reduction of 20% could be achieved without a significant detectable difference between the high-dose and low-dose images (P < 19). Conclusions: For the study comparing old and new phosphor plate technology at fixed exposure, images were better with the new technology. Using the new plate technology, dose can be decreased by ≥20%.

KW - Computed radiography

KW - Neonatal chest imaging

KW - Radiation dose

UR - http://www.scopus.com/inward/record.url?scp=78651103013&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78651103013&partnerID=8YFLogxK

U2 - 10.1016/j.acra.2010.09.015

DO - 10.1016/j.acra.2010.09.015

M3 - Article

C2 - 21232684

AN - SCOPUS:78651103013

VL - 18

SP - 197

EP - 198

JO - Academic Radiology

JF - Academic Radiology

SN - 1076-6332

IS - 2

ER -