Finite element studies of some juxtarticular stress changes due to localized subchondral stiffening

Thomas D. Brown, Eric L. Radin, R. Bruce Martin, David Burr

Research output: Contribution to journalArticle

108 Citations (Scopus)

Abstract

A finite element analysis was undertaken in concert with an animal model of mechanically-induced osteoarthritis. The numerical model was used to explore stress transmission anomalies associated with localized subchondral stiffening due to implantation of small cylindrical plugs immediately below the subchondral plate of sheep. The quasi-static, plane strain computational formulation included solution of the non-linear intra-articular contact problem, and was validated by comparison with a corresponding analytical solution and with the in vivo experimental results. The numerical results showed that stress aberrations due to metal implant insertion were felt most greatly in the bone immediately surrounding the implant, but that nominal compressive stress elevations up to about 50% could also be induced in the overlying deep hyaline cartilage layer. This localized cartilage stress elevation following the insertion of a metal plug could be seriously affected by a number of factors, including the positioning of the implant, variation in the area of intra-articular contact, or the elastic modulus of the cancellous bone and/or subchondral plate. Experimentally-observed fibrous encapsulation also reduced the cartilage stress elevation effect, but later bony remodelling and the development of a corticalized shell around the implant encapsulation served to re-elevate the local cartilage stresses.

Original languageEnglish (US)
JournalJournal of Biomechanics
Volume17
Issue number1
DOIs
StatePublished - 1984
Externally publishedYes

Fingerprint

Cartilage
Joints
Metals
Hyaline Cartilage
Finite Element Analysis
Encapsulation
Elastic Modulus
Bone
Osteoarthritis
Sheep
Animal Models
Bone and Bones
Aberrations
Compressive stress
Contacts (fluid mechanics)
Numerical models
Animals
Elastic moduli
Finite element method
Cancellous Bone

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Finite element studies of some juxtarticular stress changes due to localized subchondral stiffening. / Brown, Thomas D.; Radin, Eric L.; Martin, R. Bruce; Burr, David.

In: Journal of Biomechanics, Vol. 17, No. 1, 1984.

Research output: Contribution to journalArticle

Brown, Thomas D. ; Radin, Eric L. ; Martin, R. Bruce ; Burr, David. / Finite element studies of some juxtarticular stress changes due to localized subchondral stiffening. In: Journal of Biomechanics. 1984 ; Vol. 17, No. 1.
@article{153f52eba54e4c32a03feaed7403d663,
title = "Finite element studies of some juxtarticular stress changes due to localized subchondral stiffening",
abstract = "A finite element analysis was undertaken in concert with an animal model of mechanically-induced osteoarthritis. The numerical model was used to explore stress transmission anomalies associated with localized subchondral stiffening due to implantation of small cylindrical plugs immediately below the subchondral plate of sheep. The quasi-static, plane strain computational formulation included solution of the non-linear intra-articular contact problem, and was validated by comparison with a corresponding analytical solution and with the in vivo experimental results. The numerical results showed that stress aberrations due to metal implant insertion were felt most greatly in the bone immediately surrounding the implant, but that nominal compressive stress elevations up to about 50{\%} could also be induced in the overlying deep hyaline cartilage layer. This localized cartilage stress elevation following the insertion of a metal plug could be seriously affected by a number of factors, including the positioning of the implant, variation in the area of intra-articular contact, or the elastic modulus of the cancellous bone and/or subchondral plate. Experimentally-observed fibrous encapsulation also reduced the cartilage stress elevation effect, but later bony remodelling and the development of a corticalized shell around the implant encapsulation served to re-elevate the local cartilage stresses.",
author = "Brown, {Thomas D.} and Radin, {Eric L.} and Martin, {R. Bruce} and David Burr",
year = "1984",
doi = "10.1016/0021-9290(84)90075-7",
language = "English (US)",
volume = "17",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Limited",
number = "1",

}

TY - JOUR

T1 - Finite element studies of some juxtarticular stress changes due to localized subchondral stiffening

AU - Brown, Thomas D.

AU - Radin, Eric L.

AU - Martin, R. Bruce

AU - Burr, David

PY - 1984

Y1 - 1984

N2 - A finite element analysis was undertaken in concert with an animal model of mechanically-induced osteoarthritis. The numerical model was used to explore stress transmission anomalies associated with localized subchondral stiffening due to implantation of small cylindrical plugs immediately below the subchondral plate of sheep. The quasi-static, plane strain computational formulation included solution of the non-linear intra-articular contact problem, and was validated by comparison with a corresponding analytical solution and with the in vivo experimental results. The numerical results showed that stress aberrations due to metal implant insertion were felt most greatly in the bone immediately surrounding the implant, but that nominal compressive stress elevations up to about 50% could also be induced in the overlying deep hyaline cartilage layer. This localized cartilage stress elevation following the insertion of a metal plug could be seriously affected by a number of factors, including the positioning of the implant, variation in the area of intra-articular contact, or the elastic modulus of the cancellous bone and/or subchondral plate. Experimentally-observed fibrous encapsulation also reduced the cartilage stress elevation effect, but later bony remodelling and the development of a corticalized shell around the implant encapsulation served to re-elevate the local cartilage stresses.

AB - A finite element analysis was undertaken in concert with an animal model of mechanically-induced osteoarthritis. The numerical model was used to explore stress transmission anomalies associated with localized subchondral stiffening due to implantation of small cylindrical plugs immediately below the subchondral plate of sheep. The quasi-static, plane strain computational formulation included solution of the non-linear intra-articular contact problem, and was validated by comparison with a corresponding analytical solution and with the in vivo experimental results. The numerical results showed that stress aberrations due to metal implant insertion were felt most greatly in the bone immediately surrounding the implant, but that nominal compressive stress elevations up to about 50% could also be induced in the overlying deep hyaline cartilage layer. This localized cartilage stress elevation following the insertion of a metal plug could be seriously affected by a number of factors, including the positioning of the implant, variation in the area of intra-articular contact, or the elastic modulus of the cancellous bone and/or subchondral plate. Experimentally-observed fibrous encapsulation also reduced the cartilage stress elevation effect, but later bony remodelling and the development of a corticalized shell around the implant encapsulation served to re-elevate the local cartilage stresses.

UR - http://www.scopus.com/inward/record.url?scp=0021319135&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0021319135&partnerID=8YFLogxK

U2 - 10.1016/0021-9290(84)90075-7

DO - 10.1016/0021-9290(84)90075-7

M3 - Article

VL - 17

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290

IS - 1

ER -