Flow limitation in infants assessed by negative expiratory pressure

Marcus H. Jones, Stephanie Davis, Jeffrey A. Kisling, John M. Howard, Robert Castile, Robert Tepper

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Forced expiratory flows by the rapid compression technique are often used to assess airway function in infants; however, it remains unclear as to whether flow limitation (FL) is achieved. Studies in adults have used negative expiratory pressure (NEP) at the airway opening as a noninvasive technique to assess whether FL is achieved. An increase in flow with NEP indicates that FL has not been achieved, whereas no increase in flow with NEP indicates FL has been achieved. In the adult studies, the change in flow was assessed by visual inspection of the flow-volume curve. We evaluated whether NEP could be used to assess FL during forced expiration in infants. In addition, we quantified the change in flow secondary to NEP. We applied -5 cm H2O NEP to four infants during forced expiratory maneuvers. The step increase in flow with NEP was always less than 5% at high jacket compression pressures and consistent with FL. For one subject, FL was also confirmed from isovolume pressure flow-curves measured with an esophageal catheter. We conclude that NEP can be used in infants to assess FL during forced expiratory maneuvers by the rapid compression technique.

Original languageEnglish
Pages (from-to)713-717
Number of pages5
JournalAmerican Journal of Respiratory and Critical Care Medicine
Volume161
Issue number3 I
StatePublished - 2000

Fingerprint

Pressure
Catheters

ASJC Scopus subject areas

  • Pulmonary and Respiratory Medicine

Cite this

Flow limitation in infants assessed by negative expiratory pressure. / Jones, Marcus H.; Davis, Stephanie; Kisling, Jeffrey A.; Howard, John M.; Castile, Robert; Tepper, Robert.

In: American Journal of Respiratory and Critical Care Medicine, Vol. 161, No. 3 I, 2000, p. 713-717.

Research output: Contribution to journalArticle

Jones, Marcus H. ; Davis, Stephanie ; Kisling, Jeffrey A. ; Howard, John M. ; Castile, Robert ; Tepper, Robert. / Flow limitation in infants assessed by negative expiratory pressure. In: American Journal of Respiratory and Critical Care Medicine. 2000 ; Vol. 161, No. 3 I. pp. 713-717.
@article{93eb3e4d9dc64c478738c7132d55b5a4,
title = "Flow limitation in infants assessed by negative expiratory pressure",
abstract = "Forced expiratory flows by the rapid compression technique are often used to assess airway function in infants; however, it remains unclear as to whether flow limitation (FL) is achieved. Studies in adults have used negative expiratory pressure (NEP) at the airway opening as a noninvasive technique to assess whether FL is achieved. An increase in flow with NEP indicates that FL has not been achieved, whereas no increase in flow with NEP indicates FL has been achieved. In the adult studies, the change in flow was assessed by visual inspection of the flow-volume curve. We evaluated whether NEP could be used to assess FL during forced expiration in infants. In addition, we quantified the change in flow secondary to NEP. We applied -5 cm H2O NEP to four infants during forced expiratory maneuvers. The step increase in flow with NEP was always less than 5{\%} at high jacket compression pressures and consistent with FL. For one subject, FL was also confirmed from isovolume pressure flow-curves measured with an esophageal catheter. We conclude that NEP can be used in infants to assess FL during forced expiratory maneuvers by the rapid compression technique.",
author = "Jones, {Marcus H.} and Stephanie Davis and Kisling, {Jeffrey A.} and Howard, {John M.} and Robert Castile and Robert Tepper",
year = "2000",
language = "English",
volume = "161",
pages = "713--717",
journal = "American Journal of Respiratory and Critical Care Medicine",
issn = "1073-449X",
publisher = "American Thoracic Society",
number = "3 I",

}

TY - JOUR

T1 - Flow limitation in infants assessed by negative expiratory pressure

AU - Jones, Marcus H.

AU - Davis, Stephanie

AU - Kisling, Jeffrey A.

AU - Howard, John M.

AU - Castile, Robert

AU - Tepper, Robert

PY - 2000

Y1 - 2000

N2 - Forced expiratory flows by the rapid compression technique are often used to assess airway function in infants; however, it remains unclear as to whether flow limitation (FL) is achieved. Studies in adults have used negative expiratory pressure (NEP) at the airway opening as a noninvasive technique to assess whether FL is achieved. An increase in flow with NEP indicates that FL has not been achieved, whereas no increase in flow with NEP indicates FL has been achieved. In the adult studies, the change in flow was assessed by visual inspection of the flow-volume curve. We evaluated whether NEP could be used to assess FL during forced expiration in infants. In addition, we quantified the change in flow secondary to NEP. We applied -5 cm H2O NEP to four infants during forced expiratory maneuvers. The step increase in flow with NEP was always less than 5% at high jacket compression pressures and consistent with FL. For one subject, FL was also confirmed from isovolume pressure flow-curves measured with an esophageal catheter. We conclude that NEP can be used in infants to assess FL during forced expiratory maneuvers by the rapid compression technique.

AB - Forced expiratory flows by the rapid compression technique are often used to assess airway function in infants; however, it remains unclear as to whether flow limitation (FL) is achieved. Studies in adults have used negative expiratory pressure (NEP) at the airway opening as a noninvasive technique to assess whether FL is achieved. An increase in flow with NEP indicates that FL has not been achieved, whereas no increase in flow with NEP indicates FL has been achieved. In the adult studies, the change in flow was assessed by visual inspection of the flow-volume curve. We evaluated whether NEP could be used to assess FL during forced expiration in infants. In addition, we quantified the change in flow secondary to NEP. We applied -5 cm H2O NEP to four infants during forced expiratory maneuvers. The step increase in flow with NEP was always less than 5% at high jacket compression pressures and consistent with FL. For one subject, FL was also confirmed from isovolume pressure flow-curves measured with an esophageal catheter. We conclude that NEP can be used in infants to assess FL during forced expiratory maneuvers by the rapid compression technique.

UR - http://www.scopus.com/inward/record.url?scp=0034080666&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034080666&partnerID=8YFLogxK

M3 - Article

C2 - 10712312

AN - SCOPUS:0034080666

VL - 161

SP - 713

EP - 717

JO - American Journal of Respiratory and Critical Care Medicine

JF - American Journal of Respiratory and Critical Care Medicine

SN - 1073-449X

IS - 3 I

ER -