Helium-3 MR q-space imaging with radial acquisition and iterative highly constrained back-projection

Rafael L. O'Halloran, James H. Holmes, Yu-Chien Wu, Andrew Alexander, Sean B. Fain

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

An undersampled diffusion-weighted stack-of-stars acquisition is combined with iterative highly constrained back-projection to perform hyperpolarized helium-3 MR q-space imaging with combined regional correction of radiofrequency- and T1-related signal loss in a single breath-held scan. The technique is tested in computer simulations and phantom experiments and demonstrated in a healthy human volunteer with whole-lung coverage in a 13-sec breath-hold. Measures of lung microstructure at three different lung volumes are evaluated using inhaled gas volumes of 500 mL, 1000 mL, and 1500 mL to demonstrate feasibility. Phantom results demonstrate that the proposed technique is in agreement with theoretical values, as well as with a fully sampled two-dimensional Cartesian acquisition. Results from the volunteer study demonstrate that the root mean squared diffusion distance increased significantly from the 500-mL volume to the 1000-mL volume. This technique represents the first demonstration of a spatially resolved hyperpolarized helium-3 q-space imaging technique and shows promise for microstructural evaluation of lung disease in three dimensions.

Original languageEnglish (US)
Pages (from-to)41-50
Number of pages10
JournalMagnetic Resonance in Medicine
Volume63
Issue number1
DOIs
StatePublished - Jan 1 2010
Externally publishedYes

Fingerprint

Helium
Lung
Computer Simulation
Lung Diseases
Volunteers
Healthy Volunteers
Gases

Keywords

  • Diffusion
  • Helium-3
  • Hyperpolarized gase
  • HYPR
  • Iterative reconstruction
  • MRI
  • Projection imaging
  • q-space

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Helium-3 MR q-space imaging with radial acquisition and iterative highly constrained back-projection. / O'Halloran, Rafael L.; Holmes, James H.; Wu, Yu-Chien; Alexander, Andrew; Fain, Sean B.

In: Magnetic Resonance in Medicine, Vol. 63, No. 1, 01.01.2010, p. 41-50.

Research output: Contribution to journalArticle

O'Halloran, Rafael L. ; Holmes, James H. ; Wu, Yu-Chien ; Alexander, Andrew ; Fain, Sean B. / Helium-3 MR q-space imaging with radial acquisition and iterative highly constrained back-projection. In: Magnetic Resonance in Medicine. 2010 ; Vol. 63, No. 1. pp. 41-50.
@article{149c1e2b83e443d8a3dc65383d5f0531,
title = "Helium-3 MR q-space imaging with radial acquisition and iterative highly constrained back-projection",
abstract = "An undersampled diffusion-weighted stack-of-stars acquisition is combined with iterative highly constrained back-projection to perform hyperpolarized helium-3 MR q-space imaging with combined regional correction of radiofrequency- and T1-related signal loss in a single breath-held scan. The technique is tested in computer simulations and phantom experiments and demonstrated in a healthy human volunteer with whole-lung coverage in a 13-sec breath-hold. Measures of lung microstructure at three different lung volumes are evaluated using inhaled gas volumes of 500 mL, 1000 mL, and 1500 mL to demonstrate feasibility. Phantom results demonstrate that the proposed technique is in agreement with theoretical values, as well as with a fully sampled two-dimensional Cartesian acquisition. Results from the volunteer study demonstrate that the root mean squared diffusion distance increased significantly from the 500-mL volume to the 1000-mL volume. This technique represents the first demonstration of a spatially resolved hyperpolarized helium-3 q-space imaging technique and shows promise for microstructural evaluation of lung disease in three dimensions.",
keywords = "Diffusion, Helium-3, Hyperpolarized gase, HYPR, Iterative reconstruction, MRI, Projection imaging, q-space",
author = "O'Halloran, {Rafael L.} and Holmes, {James H.} and Yu-Chien Wu and Andrew Alexander and Fain, {Sean B.}",
year = "2010",
month = "1",
day = "1",
doi = "10.1002/mrm.22158",
language = "English (US)",
volume = "63",
pages = "41--50",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Helium-3 MR q-space imaging with radial acquisition and iterative highly constrained back-projection

AU - O'Halloran, Rafael L.

AU - Holmes, James H.

AU - Wu, Yu-Chien

AU - Alexander, Andrew

AU - Fain, Sean B.

PY - 2010/1/1

Y1 - 2010/1/1

N2 - An undersampled diffusion-weighted stack-of-stars acquisition is combined with iterative highly constrained back-projection to perform hyperpolarized helium-3 MR q-space imaging with combined regional correction of radiofrequency- and T1-related signal loss in a single breath-held scan. The technique is tested in computer simulations and phantom experiments and demonstrated in a healthy human volunteer with whole-lung coverage in a 13-sec breath-hold. Measures of lung microstructure at three different lung volumes are evaluated using inhaled gas volumes of 500 mL, 1000 mL, and 1500 mL to demonstrate feasibility. Phantom results demonstrate that the proposed technique is in agreement with theoretical values, as well as with a fully sampled two-dimensional Cartesian acquisition. Results from the volunteer study demonstrate that the root mean squared diffusion distance increased significantly from the 500-mL volume to the 1000-mL volume. This technique represents the first demonstration of a spatially resolved hyperpolarized helium-3 q-space imaging technique and shows promise for microstructural evaluation of lung disease in three dimensions.

AB - An undersampled diffusion-weighted stack-of-stars acquisition is combined with iterative highly constrained back-projection to perform hyperpolarized helium-3 MR q-space imaging with combined regional correction of radiofrequency- and T1-related signal loss in a single breath-held scan. The technique is tested in computer simulations and phantom experiments and demonstrated in a healthy human volunteer with whole-lung coverage in a 13-sec breath-hold. Measures of lung microstructure at three different lung volumes are evaluated using inhaled gas volumes of 500 mL, 1000 mL, and 1500 mL to demonstrate feasibility. Phantom results demonstrate that the proposed technique is in agreement with theoretical values, as well as with a fully sampled two-dimensional Cartesian acquisition. Results from the volunteer study demonstrate that the root mean squared diffusion distance increased significantly from the 500-mL volume to the 1000-mL volume. This technique represents the first demonstration of a spatially resolved hyperpolarized helium-3 q-space imaging technique and shows promise for microstructural evaluation of lung disease in three dimensions.

KW - Diffusion

KW - Helium-3

KW - Hyperpolarized gase

KW - HYPR

KW - Iterative reconstruction

KW - MRI

KW - Projection imaging

KW - q-space

UR - http://www.scopus.com/inward/record.url?scp=73349091183&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=73349091183&partnerID=8YFLogxK

U2 - 10.1002/mrm.22158

DO - 10.1002/mrm.22158

M3 - Article

C2 - 19953515

AN - SCOPUS:73349091183

VL - 63

SP - 41

EP - 50

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 1

ER -