Highly sensitive intravascular photoacoustic imaging with a collinear catheter probe

Yingchun Cao, Jie Hui, Ayeeshik Kole, Pu Wang, Weibiao Chen, Michael Sturek, Ji Xin Cheng

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

A collinear catheter for label-free intravascular photoacoustic imaging was developed with a diameter of 1.6 mm. The collinear overlap between optical and acoustic waves enabled photoacoustic imaging of a human coronary artery from lumen to perivascular fat.

Original languageEnglish (US)
Title of host publication2016 Conference on Lasers and Electro-Optics, CLEO 2016
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Electronic)9781943580118
StatePublished - Dec 16 2016
Event2016 Conference on Lasers and Electro-Optics, CLEO 2016 - San Jose, United States
Duration: Jun 5 2016Jun 10 2016

Other

Other2016 Conference on Lasers and Electro-Optics, CLEO 2016
CountryUnited States
CitySan Jose
Period6/5/166/10/16

Fingerprint

lumens
Photoacoustic effect
Catheters
fats
arteries
Imaging techniques
acoustics
probes
Oils and fats
Labels
Fats
Acoustic waves

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Electronic, Optical and Magnetic Materials
  • Electrical and Electronic Engineering

Cite this

Cao, Y., Hui, J., Kole, A., Wang, P., Chen, W., Sturek, M., & Cheng, J. X. (2016). Highly sensitive intravascular photoacoustic imaging with a collinear catheter probe. In 2016 Conference on Lasers and Electro-Optics, CLEO 2016 [7787361] Institute of Electrical and Electronics Engineers Inc..

Highly sensitive intravascular photoacoustic imaging with a collinear catheter probe. / Cao, Yingchun; Hui, Jie; Kole, Ayeeshik; Wang, Pu; Chen, Weibiao; Sturek, Michael; Cheng, Ji Xin.

2016 Conference on Lasers and Electro-Optics, CLEO 2016. Institute of Electrical and Electronics Engineers Inc., 2016. 7787361.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Cao, Y, Hui, J, Kole, A, Wang, P, Chen, W, Sturek, M & Cheng, JX 2016, Highly sensitive intravascular photoacoustic imaging with a collinear catheter probe. in 2016 Conference on Lasers and Electro-Optics, CLEO 2016., 7787361, Institute of Electrical and Electronics Engineers Inc., 2016 Conference on Lasers and Electro-Optics, CLEO 2016, San Jose, United States, 6/5/16.
Cao Y, Hui J, Kole A, Wang P, Chen W, Sturek M et al. Highly sensitive intravascular photoacoustic imaging with a collinear catheter probe. In 2016 Conference on Lasers and Electro-Optics, CLEO 2016. Institute of Electrical and Electronics Engineers Inc. 2016. 7787361
Cao, Yingchun ; Hui, Jie ; Kole, Ayeeshik ; Wang, Pu ; Chen, Weibiao ; Sturek, Michael ; Cheng, Ji Xin. / Highly sensitive intravascular photoacoustic imaging with a collinear catheter probe. 2016 Conference on Lasers and Electro-Optics, CLEO 2016. Institute of Electrical and Electronics Engineers Inc., 2016.
@inproceedings{d5a57b5423304d1389375e995815015f,
title = "Highly sensitive intravascular photoacoustic imaging with a collinear catheter probe",
abstract = "A collinear catheter for label-free intravascular photoacoustic imaging was developed with a diameter of 1.6 mm. The collinear overlap between optical and acoustic waves enabled photoacoustic imaging of a human coronary artery from lumen to perivascular fat.",
author = "Yingchun Cao and Jie Hui and Ayeeshik Kole and Pu Wang and Weibiao Chen and Michael Sturek and Cheng, {Ji Xin}",
year = "2016",
month = "12",
day = "16",
language = "English (US)",
booktitle = "2016 Conference on Lasers and Electro-Optics, CLEO 2016",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Highly sensitive intravascular photoacoustic imaging with a collinear catheter probe

AU - Cao, Yingchun

AU - Hui, Jie

AU - Kole, Ayeeshik

AU - Wang, Pu

AU - Chen, Weibiao

AU - Sturek, Michael

AU - Cheng, Ji Xin

PY - 2016/12/16

Y1 - 2016/12/16

N2 - A collinear catheter for label-free intravascular photoacoustic imaging was developed with a diameter of 1.6 mm. The collinear overlap between optical and acoustic waves enabled photoacoustic imaging of a human coronary artery from lumen to perivascular fat.

AB - A collinear catheter for label-free intravascular photoacoustic imaging was developed with a diameter of 1.6 mm. The collinear overlap between optical and acoustic waves enabled photoacoustic imaging of a human coronary artery from lumen to perivascular fat.

UR - http://www.scopus.com/inward/record.url?scp=85010689153&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85010689153&partnerID=8YFLogxK

M3 - Conference contribution

BT - 2016 Conference on Lasers and Electro-Optics, CLEO 2016

PB - Institute of Electrical and Electronics Engineers Inc.

ER -