Image Guidance-Based Target Volume Margin Expansion in IMRT of Head and Neck Cancer

Shiv P. Srivastava, Chee Wai Cheng, Indra J. Das

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

This study quantifies the setup uncertainties to optimize the planning target volume (PTV) margin based on daily image guidance, its dosimetric impact, and radiobiological implication for intensity-modulated radiation therapy (IMRT) in head and neck cancer. Ten patients were retrospectively chosen who had been treated with IMRT and with daily image-guided radiation therapy (IGRT). The daily setup errors of the 10 patients from on-board imaging for the entire treatment were analyzed. Planning target volumes were generated by expanding the clinical target volumes (CTVs) with 0 to 10 mm margins. The IMRT plans with the same dose–volume constraints were created in an Eclipse treatment planning system. The effect of volume expansion was analyzed with biological indices such as tumor control probability, normal tissue complication probability (NTCP), and equivalent uniform dose. Analysis of 906 daily setup corrections using daily IGRT showed that 98% of the daily setups are within ±5 mm. The relative increase in PTV-CTV volume from 0 to 10 mm margins provides nearly 4-fold volume increase and is linearly related to monitor unit (MU). The increase in MU is about 5%/mm margin increase. The relative increase in NTCP of parotids from 5 to 10 mm margins is 3.2 ± 1.15. Increase in PTV margin increases extra tissue volume with a corresponding increase in MU for treatment and NTCP values. Even a small margin increase (eg, 1 mm) may result in increase of more than 20% in relative extra volume and 15% in NTCP value of organs at risk (OARs). With image guidance, the setup uncertainty could be achieved within ±5 mm for 98% of the treatments, and a margin

Original languageEnglish (US)
Pages (from-to)107-113
Number of pages7
JournalTechnology in Cancer Research and Treatment
Volume15
Issue number1
DOIs
StatePublished - Feb 1 2016

Fingerprint

Head and Neck Neoplasms
Radiotherapy
Image-Guided Radiotherapy
Uncertainty
Organs at Risk
Therapeutics
Neoplasms

Keywords

  • H-N
  • IGRT
  • IMRT
  • PTV margin

ASJC Scopus subject areas

  • Cancer Research
  • Oncology

Cite this

Image Guidance-Based Target Volume Margin Expansion in IMRT of Head and Neck Cancer. / Srivastava, Shiv P.; Cheng, Chee Wai; Das, Indra J.

In: Technology in Cancer Research and Treatment, Vol. 15, No. 1, 01.02.2016, p. 107-113.

Research output: Contribution to journalArticle

Srivastava, Shiv P. ; Cheng, Chee Wai ; Das, Indra J. / Image Guidance-Based Target Volume Margin Expansion in IMRT of Head and Neck Cancer. In: Technology in Cancer Research and Treatment. 2016 ; Vol. 15, No. 1. pp. 107-113.
@article{9ac2586a7ea34774b491e3b7a6878171,
title = "Image Guidance-Based Target Volume Margin Expansion in IMRT of Head and Neck Cancer",
abstract = "This study quantifies the setup uncertainties to optimize the planning target volume (PTV) margin based on daily image guidance, its dosimetric impact, and radiobiological implication for intensity-modulated radiation therapy (IMRT) in head and neck cancer. Ten patients were retrospectively chosen who had been treated with IMRT and with daily image-guided radiation therapy (IGRT). The daily setup errors of the 10 patients from on-board imaging for the entire treatment were analyzed. Planning target volumes were generated by expanding the clinical target volumes (CTVs) with 0 to 10 mm margins. The IMRT plans with the same dose–volume constraints were created in an Eclipse treatment planning system. The effect of volume expansion was analyzed with biological indices such as tumor control probability, normal tissue complication probability (NTCP), and equivalent uniform dose. Analysis of 906 daily setup corrections using daily IGRT showed that 98{\%} of the daily setups are within ±5 mm. The relative increase in PTV-CTV volume from 0 to 10 mm margins provides nearly 4-fold volume increase and is linearly related to monitor unit (MU). The increase in MU is about 5{\%}/mm margin increase. The relative increase in NTCP of parotids from 5 to 10 mm margins is 3.2 ± 1.15. Increase in PTV margin increases extra tissue volume with a corresponding increase in MU for treatment and NTCP values. Even a small margin increase (eg, 1 mm) may result in increase of more than 20{\%} in relative extra volume and 15{\%} in NTCP value of organs at risk (OARs). With image guidance, the setup uncertainty could be achieved within ±5 mm for 98{\%} of the treatments, and a margin",
keywords = "H-N, IGRT, IMRT, PTV margin",
author = "Srivastava, {Shiv P.} and Cheng, {Chee Wai} and Das, {Indra J.}",
year = "2016",
month = "2",
day = "1",
doi = "10.1177/1533034614561162",
language = "English (US)",
volume = "15",
pages = "107--113",
journal = "Technology in Cancer Research and Treatment",
issn = "1533-0346",
publisher = "Adenine Press",
number = "1",

}

TY - JOUR

T1 - Image Guidance-Based Target Volume Margin Expansion in IMRT of Head and Neck Cancer

AU - Srivastava, Shiv P.

AU - Cheng, Chee Wai

AU - Das, Indra J.

PY - 2016/2/1

Y1 - 2016/2/1

N2 - This study quantifies the setup uncertainties to optimize the planning target volume (PTV) margin based on daily image guidance, its dosimetric impact, and radiobiological implication for intensity-modulated radiation therapy (IMRT) in head and neck cancer. Ten patients were retrospectively chosen who had been treated with IMRT and with daily image-guided radiation therapy (IGRT). The daily setup errors of the 10 patients from on-board imaging for the entire treatment were analyzed. Planning target volumes were generated by expanding the clinical target volumes (CTVs) with 0 to 10 mm margins. The IMRT plans with the same dose–volume constraints were created in an Eclipse treatment planning system. The effect of volume expansion was analyzed with biological indices such as tumor control probability, normal tissue complication probability (NTCP), and equivalent uniform dose. Analysis of 906 daily setup corrections using daily IGRT showed that 98% of the daily setups are within ±5 mm. The relative increase in PTV-CTV volume from 0 to 10 mm margins provides nearly 4-fold volume increase and is linearly related to monitor unit (MU). The increase in MU is about 5%/mm margin increase. The relative increase in NTCP of parotids from 5 to 10 mm margins is 3.2 ± 1.15. Increase in PTV margin increases extra tissue volume with a corresponding increase in MU for treatment and NTCP values. Even a small margin increase (eg, 1 mm) may result in increase of more than 20% in relative extra volume and 15% in NTCP value of organs at risk (OARs). With image guidance, the setup uncertainty could be achieved within ±5 mm for 98% of the treatments, and a margin

AB - This study quantifies the setup uncertainties to optimize the planning target volume (PTV) margin based on daily image guidance, its dosimetric impact, and radiobiological implication for intensity-modulated radiation therapy (IMRT) in head and neck cancer. Ten patients were retrospectively chosen who had been treated with IMRT and with daily image-guided radiation therapy (IGRT). The daily setup errors of the 10 patients from on-board imaging for the entire treatment were analyzed. Planning target volumes were generated by expanding the clinical target volumes (CTVs) with 0 to 10 mm margins. The IMRT plans with the same dose–volume constraints were created in an Eclipse treatment planning system. The effect of volume expansion was analyzed with biological indices such as tumor control probability, normal tissue complication probability (NTCP), and equivalent uniform dose. Analysis of 906 daily setup corrections using daily IGRT showed that 98% of the daily setups are within ±5 mm. The relative increase in PTV-CTV volume from 0 to 10 mm margins provides nearly 4-fold volume increase and is linearly related to monitor unit (MU). The increase in MU is about 5%/mm margin increase. The relative increase in NTCP of parotids from 5 to 10 mm margins is 3.2 ± 1.15. Increase in PTV margin increases extra tissue volume with a corresponding increase in MU for treatment and NTCP values. Even a small margin increase (eg, 1 mm) may result in increase of more than 20% in relative extra volume and 15% in NTCP value of organs at risk (OARs). With image guidance, the setup uncertainty could be achieved within ±5 mm for 98% of the treatments, and a margin

KW - H-N

KW - IGRT

KW - IMRT

KW - PTV margin

UR - http://www.scopus.com/inward/record.url?scp=84957111983&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84957111983&partnerID=8YFLogxK

U2 - 10.1177/1533034614561162

DO - 10.1177/1533034614561162

M3 - Article

AN - SCOPUS:84957111983

VL - 15

SP - 107

EP - 113

JO - Technology in Cancer Research and Treatment

JF - Technology in Cancer Research and Treatment

SN - 1533-0346

IS - 1

ER -