Improved detection of Histoplasma antigenemia following dissociation of immune complexes

S. Swartzentruber, A. LeMonte, J. Witt, D. Fuller, Thomas Davis, Chadi Hage, P. Connolly, M. Durkin, L. J. Wheat

Research output: Contribution to journalArticle

36 Citations (Scopus)

Abstract

The sensitivity for detection of Histoplasma antigen is lower in serum than in urine. In other antigen assays, treatment of serum at 104°C in the presence of EDTA was required for detection of antigenemia. Sensitivity and specificity for detection of Histoplasma antigenemia were examined with or without EDTA heat treatment of the serum using the MVista Histoplasma antigen enzyme immunoassay. A total of 94.6% of serum specimens from patients with AIDS and histoplasmosis that were negative untreated were positive after EDTA-heat treatment. Two-thirds of the negative serum specimens from patients with probable histoplasmosis, based upon clinical suspicion and Histoplasma antigenuria, were positive after heat treatment. Specificity was 99.0% in controls, including healthy subjects and patients in whom histoplasmosis or blastomycosis, were excluded. Precision and reproducibility were good and excellent, respectively. These findings demonstrate improvement in sensitivity without reduction in specificity, precision, or reproducibility after heat-EDTA treatment.

Original languageEnglish
Pages (from-to)320-322
Number of pages3
JournalClinical and Vaccine Immunology
Volume16
Issue number3
DOIs
StatePublished - Mar 2009

Fingerprint

Histoplasma
Antigen-Antibody Complex
Edetic Acid
Histoplasmosis
Hot Temperature
Heat treatment
Serum
Antigens
Blastomycosis
Therapeutics
Assays
Immunoenzyme Techniques
Healthy Volunteers
Acquired Immunodeficiency Syndrome
Urine
Enzymes
Sensitivity and Specificity

ASJC Scopus subject areas

  • Clinical Biochemistry
  • Immunology
  • Immunology and Allergy
  • Microbiology (medical)

Cite this

Improved detection of Histoplasma antigenemia following dissociation of immune complexes. / Swartzentruber, S.; LeMonte, A.; Witt, J.; Fuller, D.; Davis, Thomas; Hage, Chadi; Connolly, P.; Durkin, M.; Wheat, L. J.

In: Clinical and Vaccine Immunology, Vol. 16, No. 3, 03.2009, p. 320-322.

Research output: Contribution to journalArticle

Swartzentruber, S, LeMonte, A, Witt, J, Fuller, D, Davis, T, Hage, C, Connolly, P, Durkin, M & Wheat, LJ 2009, 'Improved detection of Histoplasma antigenemia following dissociation of immune complexes', Clinical and Vaccine Immunology, vol. 16, no. 3, pp. 320-322. https://doi.org/10.1128/CVI.00409-08
Swartzentruber, S. ; LeMonte, A. ; Witt, J. ; Fuller, D. ; Davis, Thomas ; Hage, Chadi ; Connolly, P. ; Durkin, M. ; Wheat, L. J. / Improved detection of Histoplasma antigenemia following dissociation of immune complexes. In: Clinical and Vaccine Immunology. 2009 ; Vol. 16, No. 3. pp. 320-322.
@article{9c48a5fa625b4f609e31e99bbc3bf020,
title = "Improved detection of Histoplasma antigenemia following dissociation of immune complexes",
abstract = "The sensitivity for detection of Histoplasma antigen is lower in serum than in urine. In other antigen assays, treatment of serum at 104°C in the presence of EDTA was required for detection of antigenemia. Sensitivity and specificity for detection of Histoplasma antigenemia were examined with or without EDTA heat treatment of the serum using the MVista Histoplasma antigen enzyme immunoassay. A total of 94.6{\%} of serum specimens from patients with AIDS and histoplasmosis that were negative untreated were positive after EDTA-heat treatment. Two-thirds of the negative serum specimens from patients with probable histoplasmosis, based upon clinical suspicion and Histoplasma antigenuria, were positive after heat treatment. Specificity was 99.0{\%} in controls, including healthy subjects and patients in whom histoplasmosis or blastomycosis, were excluded. Precision and reproducibility were good and excellent, respectively. These findings demonstrate improvement in sensitivity without reduction in specificity, precision, or reproducibility after heat-EDTA treatment.",
author = "S. Swartzentruber and A. LeMonte and J. Witt and D. Fuller and Thomas Davis and Chadi Hage and P. Connolly and M. Durkin and Wheat, {L. J.}",
year = "2009",
month = "3",
doi = "10.1128/CVI.00409-08",
language = "English",
volume = "16",
pages = "320--322",
journal = "Clinical and Vaccine Immunology",
issn = "1556-6811",
publisher = "American Society for Microbiology",
number = "3",

}

TY - JOUR

T1 - Improved detection of Histoplasma antigenemia following dissociation of immune complexes

AU - Swartzentruber, S.

AU - LeMonte, A.

AU - Witt, J.

AU - Fuller, D.

AU - Davis, Thomas

AU - Hage, Chadi

AU - Connolly, P.

AU - Durkin, M.

AU - Wheat, L. J.

PY - 2009/3

Y1 - 2009/3

N2 - The sensitivity for detection of Histoplasma antigen is lower in serum than in urine. In other antigen assays, treatment of serum at 104°C in the presence of EDTA was required for detection of antigenemia. Sensitivity and specificity for detection of Histoplasma antigenemia were examined with or without EDTA heat treatment of the serum using the MVista Histoplasma antigen enzyme immunoassay. A total of 94.6% of serum specimens from patients with AIDS and histoplasmosis that were negative untreated were positive after EDTA-heat treatment. Two-thirds of the negative serum specimens from patients with probable histoplasmosis, based upon clinical suspicion and Histoplasma antigenuria, were positive after heat treatment. Specificity was 99.0% in controls, including healthy subjects and patients in whom histoplasmosis or blastomycosis, were excluded. Precision and reproducibility were good and excellent, respectively. These findings demonstrate improvement in sensitivity without reduction in specificity, precision, or reproducibility after heat-EDTA treatment.

AB - The sensitivity for detection of Histoplasma antigen is lower in serum than in urine. In other antigen assays, treatment of serum at 104°C in the presence of EDTA was required for detection of antigenemia. Sensitivity and specificity for detection of Histoplasma antigenemia were examined with or without EDTA heat treatment of the serum using the MVista Histoplasma antigen enzyme immunoassay. A total of 94.6% of serum specimens from patients with AIDS and histoplasmosis that were negative untreated were positive after EDTA-heat treatment. Two-thirds of the negative serum specimens from patients with probable histoplasmosis, based upon clinical suspicion and Histoplasma antigenuria, were positive after heat treatment. Specificity was 99.0% in controls, including healthy subjects and patients in whom histoplasmosis or blastomycosis, were excluded. Precision and reproducibility were good and excellent, respectively. These findings demonstrate improvement in sensitivity without reduction in specificity, precision, or reproducibility after heat-EDTA treatment.

UR - http://www.scopus.com/inward/record.url?scp=61949484696&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=61949484696&partnerID=8YFLogxK

U2 - 10.1128/CVI.00409-08

DO - 10.1128/CVI.00409-08

M3 - Article

C2 - 19144790

AN - SCOPUS:61949484696

VL - 16

SP - 320

EP - 322

JO - Clinical and Vaccine Immunology

JF - Clinical and Vaccine Immunology

SN - 1556-6811

IS - 3

ER -