In vitro ablation of cardiac valves using high-intensity focused ultrasound

Ryo Otsuka, Kana Fujikura, Kumiko Hirata, Todd Pulerwitz, Yukiko Oe, Takeki Suzuki, Robert Sciacca, Charles Marboe, Jie Wang, Daniel Burkhoff, Robert Muratore, Frederic L. Lizzi, Shunichi Homma

Research output: Contribution to journalArticle

Abstract

The purpose of this study was to evaluate the possibility of using high-intensity focused ultrasound (US), or HIFU, to create lesions in cardiac valves in vitro. Calf mitral valves and aortic valves were examined. Focused US energy was applied with an operating frequency of 4.67 MHz at a nominal acoustic power of 58 W for 0.2, 0.3 and 0.4 s at 4-s intervals. Mitral valve perforation was achieved with 20.8 ± 3.7 exposures of 0.2 s, 15.4 ± 2.1 exposures of 0.3 s or 11.2 ± 2.3 exposures of 0.4 s. Aortic valve perforation was achieved with 13.3 ± 2.4 exposures of 0.2 s, 10.3 ± 2.2 exposures of 0.3 s or 8.4 ± 1.8 exposures of 0.4 s. The mean diameter of the perforated area was 1.09 ± 0.11 mm. The lesions were slightly discolored and coagulation of tissue around the perforation was observed. HIFU was successful in perforating cardiac valves. With further refinement, HIFU may prove useful for valvulotomy or valvuloplasty.

Original languageEnglish (US)
Pages (from-to)109-114
Number of pages6
JournalUltrasound in Medicine and Biology
Volume31
Issue number1
DOIs
StatePublished - Jan 1 2005

Fingerprint

Heart Valves
Aortic Valve
Mitral Valve
ablation
perforation
Acoustics
lesions
perforating
calves
coagulation
In Vitro Techniques
intervals
acoustics

Keywords

  • Ablation
  • Cardiac valve
  • High-intensity focused ultrasound

ASJC Scopus subject areas

  • Biophysics
  • Radiological and Ultrasound Technology
  • Acoustics and Ultrasonics

Cite this

In vitro ablation of cardiac valves using high-intensity focused ultrasound. / Otsuka, Ryo; Fujikura, Kana; Hirata, Kumiko; Pulerwitz, Todd; Oe, Yukiko; Suzuki, Takeki; Sciacca, Robert; Marboe, Charles; Wang, Jie; Burkhoff, Daniel; Muratore, Robert; Lizzi, Frederic L.; Homma, Shunichi.

In: Ultrasound in Medicine and Biology, Vol. 31, No. 1, 01.01.2005, p. 109-114.

Research output: Contribution to journalArticle

Otsuka, R, Fujikura, K, Hirata, K, Pulerwitz, T, Oe, Y, Suzuki, T, Sciacca, R, Marboe, C, Wang, J, Burkhoff, D, Muratore, R, Lizzi, FL & Homma, S 2005, 'In vitro ablation of cardiac valves using high-intensity focused ultrasound', Ultrasound in Medicine and Biology, vol. 31, no. 1, pp. 109-114. https://doi.org/10.1016/j.ultrasmedbio.2004.09.009
Otsuka, Ryo ; Fujikura, Kana ; Hirata, Kumiko ; Pulerwitz, Todd ; Oe, Yukiko ; Suzuki, Takeki ; Sciacca, Robert ; Marboe, Charles ; Wang, Jie ; Burkhoff, Daniel ; Muratore, Robert ; Lizzi, Frederic L. ; Homma, Shunichi. / In vitro ablation of cardiac valves using high-intensity focused ultrasound. In: Ultrasound in Medicine and Biology. 2005 ; Vol. 31, No. 1. pp. 109-114.
@article{2cbfa7447b63499e905b245f4d8334b0,
title = "In vitro ablation of cardiac valves using high-intensity focused ultrasound",
abstract = "The purpose of this study was to evaluate the possibility of using high-intensity focused ultrasound (US), or HIFU, to create lesions in cardiac valves in vitro. Calf mitral valves and aortic valves were examined. Focused US energy was applied with an operating frequency of 4.67 MHz at a nominal acoustic power of 58 W for 0.2, 0.3 and 0.4 s at 4-s intervals. Mitral valve perforation was achieved with 20.8 ± 3.7 exposures of 0.2 s, 15.4 ± 2.1 exposures of 0.3 s or 11.2 ± 2.3 exposures of 0.4 s. Aortic valve perforation was achieved with 13.3 ± 2.4 exposures of 0.2 s, 10.3 ± 2.2 exposures of 0.3 s or 8.4 ± 1.8 exposures of 0.4 s. The mean diameter of the perforated area was 1.09 ± 0.11 mm. The lesions were slightly discolored and coagulation of tissue around the perforation was observed. HIFU was successful in perforating cardiac valves. With further refinement, HIFU may prove useful for valvulotomy or valvuloplasty.",
keywords = "Ablation, Cardiac valve, High-intensity focused ultrasound",
author = "Ryo Otsuka and Kana Fujikura and Kumiko Hirata and Todd Pulerwitz and Yukiko Oe and Takeki Suzuki and Robert Sciacca and Charles Marboe and Jie Wang and Daniel Burkhoff and Robert Muratore and Lizzi, {Frederic L.} and Shunichi Homma",
year = "2005",
month = "1",
day = "1",
doi = "10.1016/j.ultrasmedbio.2004.09.009",
language = "English (US)",
volume = "31",
pages = "109--114",
journal = "Ultrasound in Medicine and Biology",
issn = "0301-5629",
publisher = "Elsevier USA",
number = "1",

}

TY - JOUR

T1 - In vitro ablation of cardiac valves using high-intensity focused ultrasound

AU - Otsuka, Ryo

AU - Fujikura, Kana

AU - Hirata, Kumiko

AU - Pulerwitz, Todd

AU - Oe, Yukiko

AU - Suzuki, Takeki

AU - Sciacca, Robert

AU - Marboe, Charles

AU - Wang, Jie

AU - Burkhoff, Daniel

AU - Muratore, Robert

AU - Lizzi, Frederic L.

AU - Homma, Shunichi

PY - 2005/1/1

Y1 - 2005/1/1

N2 - The purpose of this study was to evaluate the possibility of using high-intensity focused ultrasound (US), or HIFU, to create lesions in cardiac valves in vitro. Calf mitral valves and aortic valves were examined. Focused US energy was applied with an operating frequency of 4.67 MHz at a nominal acoustic power of 58 W for 0.2, 0.3 and 0.4 s at 4-s intervals. Mitral valve perforation was achieved with 20.8 ± 3.7 exposures of 0.2 s, 15.4 ± 2.1 exposures of 0.3 s or 11.2 ± 2.3 exposures of 0.4 s. Aortic valve perforation was achieved with 13.3 ± 2.4 exposures of 0.2 s, 10.3 ± 2.2 exposures of 0.3 s or 8.4 ± 1.8 exposures of 0.4 s. The mean diameter of the perforated area was 1.09 ± 0.11 mm. The lesions were slightly discolored and coagulation of tissue around the perforation was observed. HIFU was successful in perforating cardiac valves. With further refinement, HIFU may prove useful for valvulotomy or valvuloplasty.

AB - The purpose of this study was to evaluate the possibility of using high-intensity focused ultrasound (US), or HIFU, to create lesions in cardiac valves in vitro. Calf mitral valves and aortic valves were examined. Focused US energy was applied with an operating frequency of 4.67 MHz at a nominal acoustic power of 58 W for 0.2, 0.3 and 0.4 s at 4-s intervals. Mitral valve perforation was achieved with 20.8 ± 3.7 exposures of 0.2 s, 15.4 ± 2.1 exposures of 0.3 s or 11.2 ± 2.3 exposures of 0.4 s. Aortic valve perforation was achieved with 13.3 ± 2.4 exposures of 0.2 s, 10.3 ± 2.2 exposures of 0.3 s or 8.4 ± 1.8 exposures of 0.4 s. The mean diameter of the perforated area was 1.09 ± 0.11 mm. The lesions were slightly discolored and coagulation of tissue around the perforation was observed. HIFU was successful in perforating cardiac valves. With further refinement, HIFU may prove useful for valvulotomy or valvuloplasty.

KW - Ablation

KW - Cardiac valve

KW - High-intensity focused ultrasound

UR - http://www.scopus.com/inward/record.url?scp=19944426712&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=19944426712&partnerID=8YFLogxK

U2 - 10.1016/j.ultrasmedbio.2004.09.009

DO - 10.1016/j.ultrasmedbio.2004.09.009

M3 - Article

C2 - 15653237

AN - SCOPUS:19944426712

VL - 31

SP - 109

EP - 114

JO - Ultrasound in Medicine and Biology

JF - Ultrasound in Medicine and Biology

SN - 0301-5629

IS - 1

ER -