Lung function distinguishes preschool children with CF from healthy controls in a multi-center setting

Gwendolyn S. Kerby, Margaret Rosenfeld, Clement L. Ren, Oscar H. Mayer, Lyndia Brumback, Robert Castile, Meeghan A. Hart, Peter Hiatt, Margaret Kloster, Robin Johnson, Paul Jones, Stephanie Davis

Research output: Contribution to journalArticle

24 Citations (Scopus)

Abstract

Rationale Conducting clinical trials in cystic fibrosis (CF) preschoolers has been limited by lack of sensitive lung function measures performed across sites. Objectives (1) Assess feasibility and short-term reproducibility of spirometry, forced oscillometry (FO), and inductance plethysmography (IP) in a multi-center preschool population; (2) compare ability of each technique to differentiate lung function of CF preschoolers and controls; (3) evaluate longitudinal changes in lung function; (4) estimate sample sizes for future trials. Methods A longitudinal, multi-center study of CF preschoolers was conducted utilizing standardized equipment, rigorous site training, and centralized lung function data review. CF subjects participated in up to four study visits 6 months apart, plus a 2-week reproducibility visit. Controls had one study visit. Results Ninety-three CF subjects and 87 controls participated. Acceptability rates were lowest for spirometry (55%) and highest for IP (77%). Spirometry success increased with age and having a prior acceptable measurement. FEV 1, FEV 0.5, and FEF 25-75 were lower for CF subjects than for controls; spirometric z-scores declined with age. IP measures of thoracoabdominal asynchrony were greater for CF subjects than for controls. FO indices did not distinguish CF from controls. FEV 1 and FEV 0.5 are able to detect the smallest treatment effect for a given sample size. Conclusions Spirometry appears more sensitive than IP or FO for detecting lung disease in CF preschoolers; spirometric indices decline with age. Future trials using spirometry should include a run-in period for training and require acceptable data prior to enrollment. However, near-normal spirometric measurements in CF preschoolers may lead to difficulty detecting a treatment effect.

Original languageEnglish (US)
Pages (from-to)597-605
Number of pages9
JournalPediatric Pulmonology
Volume47
Issue number6
DOIs
StatePublished - Jun 2012
Externally publishedYes

Fingerprint

Preschool Children
Cystic Fibrosis
Lung
Spirometry
Plethysmography
Oscillometry
Sample Size
Lung Diseases
Clinical Trials
Equipment and Supplies

Keywords

  • forced expired volume (mesh terms)
  • forced oscillometry
  • inductance plethysmography
  • preschoolers
  • spirometry

ASJC Scopus subject areas

  • Pediatrics, Perinatology, and Child Health
  • Pulmonary and Respiratory Medicine

Cite this

Lung function distinguishes preschool children with CF from healthy controls in a multi-center setting. / Kerby, Gwendolyn S.; Rosenfeld, Margaret; Ren, Clement L.; Mayer, Oscar H.; Brumback, Lyndia; Castile, Robert; Hart, Meeghan A.; Hiatt, Peter; Kloster, Margaret; Johnson, Robin; Jones, Paul; Davis, Stephanie.

In: Pediatric Pulmonology, Vol. 47, No. 6, 06.2012, p. 597-605.

Research output: Contribution to journalArticle

Kerby, GS, Rosenfeld, M, Ren, CL, Mayer, OH, Brumback, L, Castile, R, Hart, MA, Hiatt, P, Kloster, M, Johnson, R, Jones, P & Davis, S 2012, 'Lung function distinguishes preschool children with CF from healthy controls in a multi-center setting', Pediatric Pulmonology, vol. 47, no. 6, pp. 597-605. https://doi.org/10.1002/ppul.21589
Kerby, Gwendolyn S. ; Rosenfeld, Margaret ; Ren, Clement L. ; Mayer, Oscar H. ; Brumback, Lyndia ; Castile, Robert ; Hart, Meeghan A. ; Hiatt, Peter ; Kloster, Margaret ; Johnson, Robin ; Jones, Paul ; Davis, Stephanie. / Lung function distinguishes preschool children with CF from healthy controls in a multi-center setting. In: Pediatric Pulmonology. 2012 ; Vol. 47, No. 6. pp. 597-605.
@article{b29c874afa974dcb88e936335c387b00,
title = "Lung function distinguishes preschool children with CF from healthy controls in a multi-center setting",
abstract = "Rationale Conducting clinical trials in cystic fibrosis (CF) preschoolers has been limited by lack of sensitive lung function measures performed across sites. Objectives (1) Assess feasibility and short-term reproducibility of spirometry, forced oscillometry (FO), and inductance plethysmography (IP) in a multi-center preschool population; (2) compare ability of each technique to differentiate lung function of CF preschoolers and controls; (3) evaluate longitudinal changes in lung function; (4) estimate sample sizes for future trials. Methods A longitudinal, multi-center study of CF preschoolers was conducted utilizing standardized equipment, rigorous site training, and centralized lung function data review. CF subjects participated in up to four study visits 6 months apart, plus a 2-week reproducibility visit. Controls had one study visit. Results Ninety-three CF subjects and 87 controls participated. Acceptability rates were lowest for spirometry (55{\%}) and highest for IP (77{\%}). Spirometry success increased with age and having a prior acceptable measurement. FEV 1, FEV 0.5, and FEF 25-75 were lower for CF subjects than for controls; spirometric z-scores declined with age. IP measures of thoracoabdominal asynchrony were greater for CF subjects than for controls. FO indices did not distinguish CF from controls. FEV 1 and FEV 0.5 are able to detect the smallest treatment effect for a given sample size. Conclusions Spirometry appears more sensitive than IP or FO for detecting lung disease in CF preschoolers; spirometric indices decline with age. Future trials using spirometry should include a run-in period for training and require acceptable data prior to enrollment. However, near-normal spirometric measurements in CF preschoolers may lead to difficulty detecting a treatment effect.",
keywords = "forced expired volume (mesh terms), forced oscillometry, inductance plethysmography, preschoolers, spirometry",
author = "Kerby, {Gwendolyn S.} and Margaret Rosenfeld and Ren, {Clement L.} and Mayer, {Oscar H.} and Lyndia Brumback and Robert Castile and Hart, {Meeghan A.} and Peter Hiatt and Margaret Kloster and Robin Johnson and Paul Jones and Stephanie Davis",
year = "2012",
month = "6",
doi = "10.1002/ppul.21589",
language = "English (US)",
volume = "47",
pages = "597--605",
journal = "Pediatric Pulmonology",
issn = "8755-6863",
publisher = "Wiley-Liss Inc.",
number = "6",

}

TY - JOUR

T1 - Lung function distinguishes preschool children with CF from healthy controls in a multi-center setting

AU - Kerby, Gwendolyn S.

AU - Rosenfeld, Margaret

AU - Ren, Clement L.

AU - Mayer, Oscar H.

AU - Brumback, Lyndia

AU - Castile, Robert

AU - Hart, Meeghan A.

AU - Hiatt, Peter

AU - Kloster, Margaret

AU - Johnson, Robin

AU - Jones, Paul

AU - Davis, Stephanie

PY - 2012/6

Y1 - 2012/6

N2 - Rationale Conducting clinical trials in cystic fibrosis (CF) preschoolers has been limited by lack of sensitive lung function measures performed across sites. Objectives (1) Assess feasibility and short-term reproducibility of spirometry, forced oscillometry (FO), and inductance plethysmography (IP) in a multi-center preschool population; (2) compare ability of each technique to differentiate lung function of CF preschoolers and controls; (3) evaluate longitudinal changes in lung function; (4) estimate sample sizes for future trials. Methods A longitudinal, multi-center study of CF preschoolers was conducted utilizing standardized equipment, rigorous site training, and centralized lung function data review. CF subjects participated in up to four study visits 6 months apart, plus a 2-week reproducibility visit. Controls had one study visit. Results Ninety-three CF subjects and 87 controls participated. Acceptability rates were lowest for spirometry (55%) and highest for IP (77%). Spirometry success increased with age and having a prior acceptable measurement. FEV 1, FEV 0.5, and FEF 25-75 were lower for CF subjects than for controls; spirometric z-scores declined with age. IP measures of thoracoabdominal asynchrony were greater for CF subjects than for controls. FO indices did not distinguish CF from controls. FEV 1 and FEV 0.5 are able to detect the smallest treatment effect for a given sample size. Conclusions Spirometry appears more sensitive than IP or FO for detecting lung disease in CF preschoolers; spirometric indices decline with age. Future trials using spirometry should include a run-in period for training and require acceptable data prior to enrollment. However, near-normal spirometric measurements in CF preschoolers may lead to difficulty detecting a treatment effect.

AB - Rationale Conducting clinical trials in cystic fibrosis (CF) preschoolers has been limited by lack of sensitive lung function measures performed across sites. Objectives (1) Assess feasibility and short-term reproducibility of spirometry, forced oscillometry (FO), and inductance plethysmography (IP) in a multi-center preschool population; (2) compare ability of each technique to differentiate lung function of CF preschoolers and controls; (3) evaluate longitudinal changes in lung function; (4) estimate sample sizes for future trials. Methods A longitudinal, multi-center study of CF preschoolers was conducted utilizing standardized equipment, rigorous site training, and centralized lung function data review. CF subjects participated in up to four study visits 6 months apart, plus a 2-week reproducibility visit. Controls had one study visit. Results Ninety-three CF subjects and 87 controls participated. Acceptability rates were lowest for spirometry (55%) and highest for IP (77%). Spirometry success increased with age and having a prior acceptable measurement. FEV 1, FEV 0.5, and FEF 25-75 were lower for CF subjects than for controls; spirometric z-scores declined with age. IP measures of thoracoabdominal asynchrony were greater for CF subjects than for controls. FO indices did not distinguish CF from controls. FEV 1 and FEV 0.5 are able to detect the smallest treatment effect for a given sample size. Conclusions Spirometry appears more sensitive than IP or FO for detecting lung disease in CF preschoolers; spirometric indices decline with age. Future trials using spirometry should include a run-in period for training and require acceptable data prior to enrollment. However, near-normal spirometric measurements in CF preschoolers may lead to difficulty detecting a treatment effect.

KW - forced expired volume (mesh terms)

KW - forced oscillometry

KW - inductance plethysmography

KW - preschoolers

KW - spirometry

UR - http://www.scopus.com/inward/record.url?scp=84861226870&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84861226870&partnerID=8YFLogxK

U2 - 10.1002/ppul.21589

DO - 10.1002/ppul.21589

M3 - Article

C2 - 22081559

AN - SCOPUS:84861226870

VL - 47

SP - 597

EP - 605

JO - Pediatric Pulmonology

JF - Pediatric Pulmonology

SN - 8755-6863

IS - 6

ER -