Macular capillary particle velocities: a blue field and scanning laser comparison

Oliver Arend, Alon Harris, William Eric Sponsel, Andreas Remky, Martin Reim, Sebastian Wolf

Research output: Contribution to journalArticle

38 Citations (Scopus)

Abstract

• Background: Two different techniques are available for measurement of macular capillary particle velocities. The psychophysical blue field simulation technique gives data on macular leukocyte flow velocities, while the scanning laser technique provides information on capillary blood velocities of hypofluorescent segments in the macular network. Published velocity data differ considerably between the two methods. The current study was undertaken to compare the two measuring techniques in a group of healthy volunteers. • Methods: Thirty-two healthy subjects (12 man, 20 women, mean age 27 years) participated in this study. All subjects underwent entoptic leukocyte visualization by means of blue field simulation followed by fluorescein angiography using scanning laser ophthalmoscopy. • Results: The capillary blood velocities measured using the scanning laser technique were significantly higher (P < 0.01) than the flow velocities estimated with the blue field simulation technique (2.68 ± 0.3 mm/s vs 0.89 ±0.2 mm/s). No significant correlation between the flow velocities was found (r = -0.22). • Conclusion: The differences may be related to different measuring locations and/or measurements of different phenomena. The blue field technique estimates average leukocyte flow in the macular network, whereas the scanning laser technique quantifies the velocity of erythrocyte aggregates in the capillary lumen of the para- and perifoveal network. A combination of both techniques may be helpful in interpreting physiological responsiveness and altered velocity pattern in diseased eyes.

Original languageEnglish
Pages (from-to)244-249
Number of pages6
JournalGraefe's Archive for Clinical and Experimental Ophthalmology
Volume233
Issue number4
DOIs
StatePublished - Apr 1995

Fingerprint

Lasers
Leukocytes
Healthy Volunteers
Ophthalmoscopy
Eye Diseases
Fluorescein Angiography
Erythrocytes

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Macular capillary particle velocities : a blue field and scanning laser comparison. / Arend, Oliver; Harris, Alon; Sponsel, William Eric; Remky, Andreas; Reim, Martin; Wolf, Sebastian.

In: Graefe's Archive for Clinical and Experimental Ophthalmology, Vol. 233, No. 4, 04.1995, p. 244-249.

Research output: Contribution to journalArticle

Arend, Oliver ; Harris, Alon ; Sponsel, William Eric ; Remky, Andreas ; Reim, Martin ; Wolf, Sebastian. / Macular capillary particle velocities : a blue field and scanning laser comparison. In: Graefe's Archive for Clinical and Experimental Ophthalmology. 1995 ; Vol. 233, No. 4. pp. 244-249.
@article{58c5c63757c04c53b9f0ed14fc0ea8f3,
title = "Macular capillary particle velocities: a blue field and scanning laser comparison",
abstract = "• Background: Two different techniques are available for measurement of macular capillary particle velocities. The psychophysical blue field simulation technique gives data on macular leukocyte flow velocities, while the scanning laser technique provides information on capillary blood velocities of hypofluorescent segments in the macular network. Published velocity data differ considerably between the two methods. The current study was undertaken to compare the two measuring techniques in a group of healthy volunteers. • Methods: Thirty-two healthy subjects (12 man, 20 women, mean age 27 years) participated in this study. All subjects underwent entoptic leukocyte visualization by means of blue field simulation followed by fluorescein angiography using scanning laser ophthalmoscopy. • Results: The capillary blood velocities measured using the scanning laser technique were significantly higher (P < 0.01) than the flow velocities estimated with the blue field simulation technique (2.68 ± 0.3 mm/s vs 0.89 ±0.2 mm/s). No significant correlation between the flow velocities was found (r = -0.22). • Conclusion: The differences may be related to different measuring locations and/or measurements of different phenomena. The blue field technique estimates average leukocyte flow in the macular network, whereas the scanning laser technique quantifies the velocity of erythrocyte aggregates in the capillary lumen of the para- and perifoveal network. A combination of both techniques may be helpful in interpreting physiological responsiveness and altered velocity pattern in diseased eyes.",
author = "Oliver Arend and Alon Harris and Sponsel, {William Eric} and Andreas Remky and Martin Reim and Sebastian Wolf",
year = "1995",
month = "4",
doi = "10.1007/BF00183599",
language = "English",
volume = "233",
pages = "244--249",
journal = "Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie",
issn = "0065-6100",
publisher = "Springer Verlag",
number = "4",

}

TY - JOUR

T1 - Macular capillary particle velocities

T2 - a blue field and scanning laser comparison

AU - Arend, Oliver

AU - Harris, Alon

AU - Sponsel, William Eric

AU - Remky, Andreas

AU - Reim, Martin

AU - Wolf, Sebastian

PY - 1995/4

Y1 - 1995/4

N2 - • Background: Two different techniques are available for measurement of macular capillary particle velocities. The psychophysical blue field simulation technique gives data on macular leukocyte flow velocities, while the scanning laser technique provides information on capillary blood velocities of hypofluorescent segments in the macular network. Published velocity data differ considerably between the two methods. The current study was undertaken to compare the two measuring techniques in a group of healthy volunteers. • Methods: Thirty-two healthy subjects (12 man, 20 women, mean age 27 years) participated in this study. All subjects underwent entoptic leukocyte visualization by means of blue field simulation followed by fluorescein angiography using scanning laser ophthalmoscopy. • Results: The capillary blood velocities measured using the scanning laser technique were significantly higher (P < 0.01) than the flow velocities estimated with the blue field simulation technique (2.68 ± 0.3 mm/s vs 0.89 ±0.2 mm/s). No significant correlation between the flow velocities was found (r = -0.22). • Conclusion: The differences may be related to different measuring locations and/or measurements of different phenomena. The blue field technique estimates average leukocyte flow in the macular network, whereas the scanning laser technique quantifies the velocity of erythrocyte aggregates in the capillary lumen of the para- and perifoveal network. A combination of both techniques may be helpful in interpreting physiological responsiveness and altered velocity pattern in diseased eyes.

AB - • Background: Two different techniques are available for measurement of macular capillary particle velocities. The psychophysical blue field simulation technique gives data on macular leukocyte flow velocities, while the scanning laser technique provides information on capillary blood velocities of hypofluorescent segments in the macular network. Published velocity data differ considerably between the two methods. The current study was undertaken to compare the two measuring techniques in a group of healthy volunteers. • Methods: Thirty-two healthy subjects (12 man, 20 women, mean age 27 years) participated in this study. All subjects underwent entoptic leukocyte visualization by means of blue field simulation followed by fluorescein angiography using scanning laser ophthalmoscopy. • Results: The capillary blood velocities measured using the scanning laser technique were significantly higher (P < 0.01) than the flow velocities estimated with the blue field simulation technique (2.68 ± 0.3 mm/s vs 0.89 ±0.2 mm/s). No significant correlation between the flow velocities was found (r = -0.22). • Conclusion: The differences may be related to different measuring locations and/or measurements of different phenomena. The blue field technique estimates average leukocyte flow in the macular network, whereas the scanning laser technique quantifies the velocity of erythrocyte aggregates in the capillary lumen of the para- and perifoveal network. A combination of both techniques may be helpful in interpreting physiological responsiveness and altered velocity pattern in diseased eyes.

UR - http://www.scopus.com/inward/record.url?scp=0028958862&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028958862&partnerID=8YFLogxK

U2 - 10.1007/BF00183599

DO - 10.1007/BF00183599

M3 - Article

C2 - 7797089

AN - SCOPUS:0028958862

VL - 233

SP - 244

EP - 249

JO - Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie

JF - Albrecht von Graefes Archiv für Klinische und Experimentelle Ophthalmologie

SN - 0065-6100

IS - 4

ER -