Mapping the Lipid Layer of the Human Tear Film

Yoel Cohen, Stephen Trokel, Yoel Arieli, Shlomi Epshtien, Raanan Gefen, Alon Harris

Research output: Contribution to journalArticle

Abstract

PURPOSE: To describe a new method to distinguish between normal versus lipid-deficient dry eye using a Tear Film Imager (TFI). METHODS: Two groups of study subjects, controls versus lipid-deficient dry eye, were tested using the TFI. This instrument provides an accurate measurement of the thickness and spatial distribution of the muco-aqueous and lipid layers of the tear film. The nanometer thickness resolution of the TFI enables the creation of detailed maps of the lipid layer thickness (LLT) across the corneal surface. These maps are captured with a large field of view of 6.5 mm diameter. RESULTS: A LLT map taken at 1 second from a blink end in the controls appears uniform, whereas a nonuniform layer was measured in the lipid-deficient dry eye. Lipid map uniformity can quantify the spatial variation of lipid across the cornea. A case study showed the ability to distinguish between controls [lipid map uniformity (LMU) = 14 nm] and lipid-deficient dry eye (LMU = 125 nm) through characterization of the LLT distribution. CONCLUSIONS: High-resolution lateral LLT maps demonstrate the significance of the lipid layer uniformity, which may play an important role in maintaining tear film health. LLT maps and the quantitative LMU could be used to diagnose and treat patients with dry eye.

Original languageEnglish (US)
Pages (from-to)132-135
Number of pages4
JournalCornea
Volume39
Issue number1
DOIs
StatePublished - Jan 1 2020

Fingerprint

Tears
Lipids
Cornea

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Cohen, Y., Trokel, S., Arieli, Y., Epshtien, S., Gefen, R., & Harris, A. (2020). Mapping the Lipid Layer of the Human Tear Film. Cornea, 39(1), 132-135. https://doi.org/10.1097/ICO.0000000000002101

Mapping the Lipid Layer of the Human Tear Film. / Cohen, Yoel; Trokel, Stephen; Arieli, Yoel; Epshtien, Shlomi; Gefen, Raanan; Harris, Alon.

In: Cornea, Vol. 39, No. 1, 01.01.2020, p. 132-135.

Research output: Contribution to journalArticle

Cohen, Y, Trokel, S, Arieli, Y, Epshtien, S, Gefen, R & Harris, A 2020, 'Mapping the Lipid Layer of the Human Tear Film', Cornea, vol. 39, no. 1, pp. 132-135. https://doi.org/10.1097/ICO.0000000000002101
Cohen Y, Trokel S, Arieli Y, Epshtien S, Gefen R, Harris A. Mapping the Lipid Layer of the Human Tear Film. Cornea. 2020 Jan 1;39(1):132-135. https://doi.org/10.1097/ICO.0000000000002101
Cohen, Yoel ; Trokel, Stephen ; Arieli, Yoel ; Epshtien, Shlomi ; Gefen, Raanan ; Harris, Alon. / Mapping the Lipid Layer of the Human Tear Film. In: Cornea. 2020 ; Vol. 39, No. 1. pp. 132-135.
@article{03e1c54902f549c9bee18f09fff8e015,
title = "Mapping the Lipid Layer of the Human Tear Film",
abstract = "PURPOSE: To describe a new method to distinguish between normal versus lipid-deficient dry eye using a Tear Film Imager (TFI). METHODS: Two groups of study subjects, controls versus lipid-deficient dry eye, were tested using the TFI. This instrument provides an accurate measurement of the thickness and spatial distribution of the muco-aqueous and lipid layers of the tear film. The nanometer thickness resolution of the TFI enables the creation of detailed maps of the lipid layer thickness (LLT) across the corneal surface. These maps are captured with a large field of view of 6.5 mm diameter. RESULTS: A LLT map taken at 1 second from a blink end in the controls appears uniform, whereas a nonuniform layer was measured in the lipid-deficient dry eye. Lipid map uniformity can quantify the spatial variation of lipid across the cornea. A case study showed the ability to distinguish between controls [lipid map uniformity (LMU) = 14 nm] and lipid-deficient dry eye (LMU = 125 nm) through characterization of the LLT distribution. CONCLUSIONS: High-resolution lateral LLT maps demonstrate the significance of the lipid layer uniformity, which may play an important role in maintaining tear film health. LLT maps and the quantitative LMU could be used to diagnose and treat patients with dry eye.",
author = "Yoel Cohen and Stephen Trokel and Yoel Arieli and Shlomi Epshtien and Raanan Gefen and Alon Harris",
year = "2020",
month = "1",
day = "1",
doi = "10.1097/ICO.0000000000002101",
language = "English (US)",
volume = "39",
pages = "132--135",
journal = "Cornea",
issn = "0277-3740",
publisher = "Lippincott Williams and Wilkins",
number = "1",

}

TY - JOUR

T1 - Mapping the Lipid Layer of the Human Tear Film

AU - Cohen, Yoel

AU - Trokel, Stephen

AU - Arieli, Yoel

AU - Epshtien, Shlomi

AU - Gefen, Raanan

AU - Harris, Alon

PY - 2020/1/1

Y1 - 2020/1/1

N2 - PURPOSE: To describe a new method to distinguish between normal versus lipid-deficient dry eye using a Tear Film Imager (TFI). METHODS: Two groups of study subjects, controls versus lipid-deficient dry eye, were tested using the TFI. This instrument provides an accurate measurement of the thickness and spatial distribution of the muco-aqueous and lipid layers of the tear film. The nanometer thickness resolution of the TFI enables the creation of detailed maps of the lipid layer thickness (LLT) across the corneal surface. These maps are captured with a large field of view of 6.5 mm diameter. RESULTS: A LLT map taken at 1 second from a blink end in the controls appears uniform, whereas a nonuniform layer was measured in the lipid-deficient dry eye. Lipid map uniformity can quantify the spatial variation of lipid across the cornea. A case study showed the ability to distinguish between controls [lipid map uniformity (LMU) = 14 nm] and lipid-deficient dry eye (LMU = 125 nm) through characterization of the LLT distribution. CONCLUSIONS: High-resolution lateral LLT maps demonstrate the significance of the lipid layer uniformity, which may play an important role in maintaining tear film health. LLT maps and the quantitative LMU could be used to diagnose and treat patients with dry eye.

AB - PURPOSE: To describe a new method to distinguish between normal versus lipid-deficient dry eye using a Tear Film Imager (TFI). METHODS: Two groups of study subjects, controls versus lipid-deficient dry eye, were tested using the TFI. This instrument provides an accurate measurement of the thickness and spatial distribution of the muco-aqueous and lipid layers of the tear film. The nanometer thickness resolution of the TFI enables the creation of detailed maps of the lipid layer thickness (LLT) across the corneal surface. These maps are captured with a large field of view of 6.5 mm diameter. RESULTS: A LLT map taken at 1 second from a blink end in the controls appears uniform, whereas a nonuniform layer was measured in the lipid-deficient dry eye. Lipid map uniformity can quantify the spatial variation of lipid across the cornea. A case study showed the ability to distinguish between controls [lipid map uniformity (LMU) = 14 nm] and lipid-deficient dry eye (LMU = 125 nm) through characterization of the LLT distribution. CONCLUSIONS: High-resolution lateral LLT maps demonstrate the significance of the lipid layer uniformity, which may play an important role in maintaining tear film health. LLT maps and the quantitative LMU could be used to diagnose and treat patients with dry eye.

UR - http://www.scopus.com/inward/record.url?scp=85075959642&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85075959642&partnerID=8YFLogxK

U2 - 10.1097/ICO.0000000000002101

DO - 10.1097/ICO.0000000000002101

M3 - Article

C2 - 31403529

AN - SCOPUS:85075959642

VL - 39

SP - 132

EP - 135

JO - Cornea

JF - Cornea

SN - 0277-3740

IS - 1

ER -