Measurement of cardiovascular function using a novel view-sharing PET reconstruction method and tracer kinetic analysis

Paul Territo, Amanda A. Riley, Brian P. McCarthy, Gary Hutchins

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Recent advancements in PET instrumentation have made the non-invasive assessment of cardiovascular function in small animals a reality. The majority of small animal PET systems use stationary detector gantries, thus affording high temporal resolution imaging of cardiac function. Systems designed to maximize spatial resolution and detection sensitivity employing rotating gantry designs are suboptimal when high temporal resolution imaging is needed. To overcome this limitation, the current work developed a novel view-sharing data analysis scheme suitable for dynamic cardiac PET imaging using 18F-NaF as the tracer and tracer kinetic model analysis. This scheme was tested in a rat model of cardiovascular function where the relationship between direct transonic flow measures of cardiac output were highly correlated (f(x) = 1.0216x − 24.233, R = 0.9158, p < 0.001) with the new model. Similarly, derived measures of stroke volume were also highly correlated (f(x) = 0.9655x − 0.0428, R = 0.9453, p < 0.001) with the current approach. Administration of xylazine caused a statistically significant increase in stroke volume (0.32 ± 0.07 ml, p = 0.003, n = 4) and a significant decrease in both heart rate (−155 ± 7.1 beats/min, p < 0.001, n = 4) and cardiac output (−75.9 ± 23.0 ml/kg min, p = 0.01, n = 4). These findings suggest that the new sinogram binning and kinetic modeling methods produce reliable cardiac function measures suitable for longitudinal monitoring of cardiovascular function.

Original languageEnglish (US)
Article number24
JournalEJNMMI Physics
Volume3
Issue number1
DOIs
StatePublished - Dec 1 2016

Fingerprint

Cardiac Output
Stroke Volume
tracers
Cardiovascular Models
Xylazine
stroke volume
cardiac output
Kinetics
kinetics
gantry cranes
temporal resolution
Imaging techniques
Heart Rate
animals
Animals
heart rate
Transonic flow
transonic flow
high resolution
rats

Keywords

  • Cardiac output
  • Kinetic modeling
  • PET
  • View-sharing

ASJC Scopus subject areas

  • Radiation
  • Biomedical Engineering
  • Instrumentation
  • Radiology Nuclear Medicine and imaging

Cite this

Measurement of cardiovascular function using a novel view-sharing PET reconstruction method and tracer kinetic analysis. / Territo, Paul; Riley, Amanda A.; McCarthy, Brian P.; Hutchins, Gary.

In: EJNMMI Physics, Vol. 3, No. 1, 24, 01.12.2016.

Research output: Contribution to journalArticle

@article{e947c8536e8c4f52a7f00149a97d0421,
title = "Measurement of cardiovascular function using a novel view-sharing PET reconstruction method and tracer kinetic analysis",
abstract = "Recent advancements in PET instrumentation have made the non-invasive assessment of cardiovascular function in small animals a reality. The majority of small animal PET systems use stationary detector gantries, thus affording high temporal resolution imaging of cardiac function. Systems designed to maximize spatial resolution and detection sensitivity employing rotating gantry designs are suboptimal when high temporal resolution imaging is needed. To overcome this limitation, the current work developed a novel view-sharing data analysis scheme suitable for dynamic cardiac PET imaging using 18F-NaF as the tracer and tracer kinetic model analysis. This scheme was tested in a rat model of cardiovascular function where the relationship between direct transonic flow measures of cardiac output were highly correlated (f(x) = 1.0216x − 24.233, R = 0.9158, p < 0.001) with the new model. Similarly, derived measures of stroke volume were also highly correlated (f(x) = 0.9655x − 0.0428, R = 0.9453, p < 0.001) with the current approach. Administration of xylazine caused a statistically significant increase in stroke volume (0.32 ± 0.07 ml, p = 0.003, n = 4) and a significant decrease in both heart rate (−155 ± 7.1 beats/min, p < 0.001, n = 4) and cardiac output (−75.9 ± 23.0 ml/kg min, p = 0.01, n = 4). These findings suggest that the new sinogram binning and kinetic modeling methods produce reliable cardiac function measures suitable for longitudinal monitoring of cardiovascular function.",
keywords = "Cardiac output, Kinetic modeling, PET, View-sharing",
author = "Paul Territo and Riley, {Amanda A.} and McCarthy, {Brian P.} and Gary Hutchins",
year = "2016",
month = "12",
day = "1",
doi = "10.1186/s40658-016-0161-4",
language = "English (US)",
volume = "3",
journal = "EJNMMI Physics",
issn = "2197-7364",
publisher = "Springer International Publishing AG",
number = "1",

}

TY - JOUR

T1 - Measurement of cardiovascular function using a novel view-sharing PET reconstruction method and tracer kinetic analysis

AU - Territo, Paul

AU - Riley, Amanda A.

AU - McCarthy, Brian P.

AU - Hutchins, Gary

PY - 2016/12/1

Y1 - 2016/12/1

N2 - Recent advancements in PET instrumentation have made the non-invasive assessment of cardiovascular function in small animals a reality. The majority of small animal PET systems use stationary detector gantries, thus affording high temporal resolution imaging of cardiac function. Systems designed to maximize spatial resolution and detection sensitivity employing rotating gantry designs are suboptimal when high temporal resolution imaging is needed. To overcome this limitation, the current work developed a novel view-sharing data analysis scheme suitable for dynamic cardiac PET imaging using 18F-NaF as the tracer and tracer kinetic model analysis. This scheme was tested in a rat model of cardiovascular function where the relationship between direct transonic flow measures of cardiac output were highly correlated (f(x) = 1.0216x − 24.233, R = 0.9158, p < 0.001) with the new model. Similarly, derived measures of stroke volume were also highly correlated (f(x) = 0.9655x − 0.0428, R = 0.9453, p < 0.001) with the current approach. Administration of xylazine caused a statistically significant increase in stroke volume (0.32 ± 0.07 ml, p = 0.003, n = 4) and a significant decrease in both heart rate (−155 ± 7.1 beats/min, p < 0.001, n = 4) and cardiac output (−75.9 ± 23.0 ml/kg min, p = 0.01, n = 4). These findings suggest that the new sinogram binning and kinetic modeling methods produce reliable cardiac function measures suitable for longitudinal monitoring of cardiovascular function.

AB - Recent advancements in PET instrumentation have made the non-invasive assessment of cardiovascular function in small animals a reality. The majority of small animal PET systems use stationary detector gantries, thus affording high temporal resolution imaging of cardiac function. Systems designed to maximize spatial resolution and detection sensitivity employing rotating gantry designs are suboptimal when high temporal resolution imaging is needed. To overcome this limitation, the current work developed a novel view-sharing data analysis scheme suitable for dynamic cardiac PET imaging using 18F-NaF as the tracer and tracer kinetic model analysis. This scheme was tested in a rat model of cardiovascular function where the relationship between direct transonic flow measures of cardiac output were highly correlated (f(x) = 1.0216x − 24.233, R = 0.9158, p < 0.001) with the new model. Similarly, derived measures of stroke volume were also highly correlated (f(x) = 0.9655x − 0.0428, R = 0.9453, p < 0.001) with the current approach. Administration of xylazine caused a statistically significant increase in stroke volume (0.32 ± 0.07 ml, p = 0.003, n = 4) and a significant decrease in both heart rate (−155 ± 7.1 beats/min, p < 0.001, n = 4) and cardiac output (−75.9 ± 23.0 ml/kg min, p = 0.01, n = 4). These findings suggest that the new sinogram binning and kinetic modeling methods produce reliable cardiac function measures suitable for longitudinal monitoring of cardiovascular function.

KW - Cardiac output

KW - Kinetic modeling

KW - PET

KW - View-sharing

UR - http://www.scopus.com/inward/record.url?scp=84992145871&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84992145871&partnerID=8YFLogxK

U2 - 10.1186/s40658-016-0161-4

DO - 10.1186/s40658-016-0161-4

M3 - Article

C2 - 26762986

AN - SCOPUS:84992145871

VL - 3

JO - EJNMMI Physics

JF - EJNMMI Physics

SN - 2197-7364

IS - 1

M1 - 24

ER -