Mechanical properties and surface characterization of beta titanium and stainless steel orthodontic wire following topical fluoride treatment

Mary P. Walker, David Ries, Katherine Kula, Micheal Ellis, Brian Fricke

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

Objective: To study the effect of fluoride prophylactic agents on the loading and unloading mechanical properties and surface quality of beta titanium and stainless steel orthodontic wires. Materials and Methods: Rectangular beta titanium and stainless steel wires were immersed in either an acidulated fluoride agent, a neutral fluoride agent, or distilled water (control) for 1.5 hours at 37°C. After immersion, the loading and unloading elastic modulus and yield strength of the wires were measured using a 3-point bend test in a water bath at 37°C. A one-way analysis of variance and Dunnett's post hoc, α = .05, were used to analyze the mechanical testing data. Scanning electron microscopy was also used to qualitatively evaluate the wire topography as a function of the fluoride treatments. Results: Unloading mechanical properties of beta titanium and stainless steel wires were significantly decreased (P ≤ .05) after exposure to both fluoride agents. Corrosive changes in surface topography were also observed after exposure to both the neutral and the acidulated phosphate fluoride agents. Conclusions: The results suggest that using topical fluoride agents with beta titanium and stainless steel wire could decrease the functional unloading mechanical properties of the wires and potentially contribute to prolonged orthodontic treatment.

Original languageEnglish (US)
Pages (from-to)342-348
Number of pages7
JournalAngle Orthodontist
Volume77
Issue number2
DOIs
StatePublished - Mar 2007
Externally publishedYes

Fingerprint

Orthodontic Wires
Topical Fluorides
Surface Properties
Stainless Steel
Fluorides
Acidulated Phosphate Fluoride
Therapeutics
Caustics
Water
Elastic Modulus
Immersion
Orthodontics
Baths
Electron Scanning Microscopy
Analysis of Variance
beta titanium

Keywords

  • Corrosion
  • Fluoride prophylactic agents

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Mechanical properties and surface characterization of beta titanium and stainless steel orthodontic wire following topical fluoride treatment. / Walker, Mary P.; Ries, David; Kula, Katherine; Ellis, Micheal; Fricke, Brian.

In: Angle Orthodontist, Vol. 77, No. 2, 03.2007, p. 342-348.

Research output: Contribution to journalArticle

Walker, Mary P. ; Ries, David ; Kula, Katherine ; Ellis, Micheal ; Fricke, Brian. / Mechanical properties and surface characterization of beta titanium and stainless steel orthodontic wire following topical fluoride treatment. In: Angle Orthodontist. 2007 ; Vol. 77, No. 2. pp. 342-348.
@article{3d37f04f138549659acfabe7b2dc1f53,
title = "Mechanical properties and surface characterization of beta titanium and stainless steel orthodontic wire following topical fluoride treatment",
abstract = "Objective: To study the effect of fluoride prophylactic agents on the loading and unloading mechanical properties and surface quality of beta titanium and stainless steel orthodontic wires. Materials and Methods: Rectangular beta titanium and stainless steel wires were immersed in either an acidulated fluoride agent, a neutral fluoride agent, or distilled water (control) for 1.5 hours at 37°C. After immersion, the loading and unloading elastic modulus and yield strength of the wires were measured using a 3-point bend test in a water bath at 37°C. A one-way analysis of variance and Dunnett's post hoc, α = .05, were used to analyze the mechanical testing data. Scanning electron microscopy was also used to qualitatively evaluate the wire topography as a function of the fluoride treatments. Results: Unloading mechanical properties of beta titanium and stainless steel wires were significantly decreased (P ≤ .05) after exposure to both fluoride agents. Corrosive changes in surface topography were also observed after exposure to both the neutral and the acidulated phosphate fluoride agents. Conclusions: The results suggest that using topical fluoride agents with beta titanium and stainless steel wire could decrease the functional unloading mechanical properties of the wires and potentially contribute to prolonged orthodontic treatment.",
keywords = "Corrosion, Fluoride prophylactic agents",
author = "Walker, {Mary P.} and David Ries and Katherine Kula and Micheal Ellis and Brian Fricke",
year = "2007",
month = "3",
doi = "10.2319/0003-3219(2007)077[0342:MPASCO]2.0.CO;2",
language = "English (US)",
volume = "77",
pages = "342--348",
journal = "Angle Orthodontist",
issn = "0003-3219",
publisher = "E H Angle Orthodontists Research & Education Foundation, Inc.",
number = "2",

}

TY - JOUR

T1 - Mechanical properties and surface characterization of beta titanium and stainless steel orthodontic wire following topical fluoride treatment

AU - Walker, Mary P.

AU - Ries, David

AU - Kula, Katherine

AU - Ellis, Micheal

AU - Fricke, Brian

PY - 2007/3

Y1 - 2007/3

N2 - Objective: To study the effect of fluoride prophylactic agents on the loading and unloading mechanical properties and surface quality of beta titanium and stainless steel orthodontic wires. Materials and Methods: Rectangular beta titanium and stainless steel wires were immersed in either an acidulated fluoride agent, a neutral fluoride agent, or distilled water (control) for 1.5 hours at 37°C. After immersion, the loading and unloading elastic modulus and yield strength of the wires were measured using a 3-point bend test in a water bath at 37°C. A one-way analysis of variance and Dunnett's post hoc, α = .05, were used to analyze the mechanical testing data. Scanning electron microscopy was also used to qualitatively evaluate the wire topography as a function of the fluoride treatments. Results: Unloading mechanical properties of beta titanium and stainless steel wires were significantly decreased (P ≤ .05) after exposure to both fluoride agents. Corrosive changes in surface topography were also observed after exposure to both the neutral and the acidulated phosphate fluoride agents. Conclusions: The results suggest that using topical fluoride agents with beta titanium and stainless steel wire could decrease the functional unloading mechanical properties of the wires and potentially contribute to prolonged orthodontic treatment.

AB - Objective: To study the effect of fluoride prophylactic agents on the loading and unloading mechanical properties and surface quality of beta titanium and stainless steel orthodontic wires. Materials and Methods: Rectangular beta titanium and stainless steel wires were immersed in either an acidulated fluoride agent, a neutral fluoride agent, or distilled water (control) for 1.5 hours at 37°C. After immersion, the loading and unloading elastic modulus and yield strength of the wires were measured using a 3-point bend test in a water bath at 37°C. A one-way analysis of variance and Dunnett's post hoc, α = .05, were used to analyze the mechanical testing data. Scanning electron microscopy was also used to qualitatively evaluate the wire topography as a function of the fluoride treatments. Results: Unloading mechanical properties of beta titanium and stainless steel wires were significantly decreased (P ≤ .05) after exposure to both fluoride agents. Corrosive changes in surface topography were also observed after exposure to both the neutral and the acidulated phosphate fluoride agents. Conclusions: The results suggest that using topical fluoride agents with beta titanium and stainless steel wire could decrease the functional unloading mechanical properties of the wires and potentially contribute to prolonged orthodontic treatment.

KW - Corrosion

KW - Fluoride prophylactic agents

UR - http://www.scopus.com/inward/record.url?scp=33947229308&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33947229308&partnerID=8YFLogxK

U2 - 10.2319/0003-3219(2007)077[0342:MPASCO]2.0.CO;2

DO - 10.2319/0003-3219(2007)077[0342:MPASCO]2.0.CO;2

M3 - Article

C2 - 17319772

AN - SCOPUS:33947229308

VL - 77

SP - 342

EP - 348

JO - Angle Orthodontist

JF - Angle Orthodontist

SN - 0003-3219

IS - 2

ER -