Modeling of carbon-11-acetate kinetics by simultaneously fitting data from multiple ROIs coupled by common parameters

R. R. Raylman, Gary Hutchins, R. S B Beanlands, M. Schwaiger

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

One of the unique aspects of PET is its ability to noninvasively quantify metabolic processes. Metabolic rate parameters are estimated by fitting the time-activity curves from regions of interest (ROIs) placed on dynamic PET images with a kinetic model. In many cases it is possible to couple these datasets with common parameters, such as the time delay between arrival of tracer in the ROIs and the sampling site. Methods: Data from eight ROIs placed about images of the myocardium were coupled by the parameters describing the metabolite concentration in the blood. The method was evaluated by comparing estimates of k2 made using the coupled region method and the standard process of fitting data from each region separately. In addition, comparisons were made between estimates of k2 and measured myocardial oxygen consumption. Results: Very little change in mean values of k2 was obtained. The variances, however, were reduced by an average of 37%, compared to the standard method, when the common parameters were not constrained. When the values of the common metabolite parameters were constrained to values previously measured, the average variance in estimates of k2 was reduced by 30%. Conclusion: We have demonstrated that the use of this technique can significantly increase the precision of estimates of myocardial oxygen consumption utilizing 11C-acetate PET images. More precise estimates of such quantities can facilitate detection of small regional and/or temporal physiological changes measured with PET. Furthermore, this method can be utilized whenever it is known a priori that one or more kinetic model parameters has the same value for every set of ROI data.

Original languageEnglish (US)
Pages (from-to)1286-1291
Number of pages6
JournalJournal of Nuclear Medicine
Volume35
Issue number8
StatePublished - 1994
Externally publishedYes

Fingerprint

Oxygen Consumption
Myocardium
carbon-11 acetate
Datasets

Keywords

  • carbon-11-acetate
  • kinetic modeling
  • PET

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Modeling of carbon-11-acetate kinetics by simultaneously fitting data from multiple ROIs coupled by common parameters. / Raylman, R. R.; Hutchins, Gary; Beanlands, R. S B; Schwaiger, M.

In: Journal of Nuclear Medicine, Vol. 35, No. 8, 1994, p. 1286-1291.

Research output: Contribution to journalArticle

@article{2f1fbe1ae4dd4882b13173ca313cb406,
title = "Modeling of carbon-11-acetate kinetics by simultaneously fitting data from multiple ROIs coupled by common parameters",
abstract = "One of the unique aspects of PET is its ability to noninvasively quantify metabolic processes. Metabolic rate parameters are estimated by fitting the time-activity curves from regions of interest (ROIs) placed on dynamic PET images with a kinetic model. In many cases it is possible to couple these datasets with common parameters, such as the time delay between arrival of tracer in the ROIs and the sampling site. Methods: Data from eight ROIs placed about images of the myocardium were coupled by the parameters describing the metabolite concentration in the blood. The method was evaluated by comparing estimates of k2 made using the coupled region method and the standard process of fitting data from each region separately. In addition, comparisons were made between estimates of k2 and measured myocardial oxygen consumption. Results: Very little change in mean values of k2 was obtained. The variances, however, were reduced by an average of 37{\%}, compared to the standard method, when the common parameters were not constrained. When the values of the common metabolite parameters were constrained to values previously measured, the average variance in estimates of k2 was reduced by 30{\%}. Conclusion: We have demonstrated that the use of this technique can significantly increase the precision of estimates of myocardial oxygen consumption utilizing 11C-acetate PET images. More precise estimates of such quantities can facilitate detection of small regional and/or temporal physiological changes measured with PET. Furthermore, this method can be utilized whenever it is known a priori that one or more kinetic model parameters has the same value for every set of ROI data.",
keywords = "carbon-11-acetate, kinetic modeling, PET",
author = "Raylman, {R. R.} and Gary Hutchins and Beanlands, {R. S B} and M. Schwaiger",
year = "1994",
language = "English (US)",
volume = "35",
pages = "1286--1291",
journal = "Journal of Nuclear Medicine",
issn = "0161-5505",
publisher = "Society of Nuclear Medicine Inc.",
number = "8",

}

TY - JOUR

T1 - Modeling of carbon-11-acetate kinetics by simultaneously fitting data from multiple ROIs coupled by common parameters

AU - Raylman, R. R.

AU - Hutchins, Gary

AU - Beanlands, R. S B

AU - Schwaiger, M.

PY - 1994

Y1 - 1994

N2 - One of the unique aspects of PET is its ability to noninvasively quantify metabolic processes. Metabolic rate parameters are estimated by fitting the time-activity curves from regions of interest (ROIs) placed on dynamic PET images with a kinetic model. In many cases it is possible to couple these datasets with common parameters, such as the time delay between arrival of tracer in the ROIs and the sampling site. Methods: Data from eight ROIs placed about images of the myocardium were coupled by the parameters describing the metabolite concentration in the blood. The method was evaluated by comparing estimates of k2 made using the coupled region method and the standard process of fitting data from each region separately. In addition, comparisons were made between estimates of k2 and measured myocardial oxygen consumption. Results: Very little change in mean values of k2 was obtained. The variances, however, were reduced by an average of 37%, compared to the standard method, when the common parameters were not constrained. When the values of the common metabolite parameters were constrained to values previously measured, the average variance in estimates of k2 was reduced by 30%. Conclusion: We have demonstrated that the use of this technique can significantly increase the precision of estimates of myocardial oxygen consumption utilizing 11C-acetate PET images. More precise estimates of such quantities can facilitate detection of small regional and/or temporal physiological changes measured with PET. Furthermore, this method can be utilized whenever it is known a priori that one or more kinetic model parameters has the same value for every set of ROI data.

AB - One of the unique aspects of PET is its ability to noninvasively quantify metabolic processes. Metabolic rate parameters are estimated by fitting the time-activity curves from regions of interest (ROIs) placed on dynamic PET images with a kinetic model. In many cases it is possible to couple these datasets with common parameters, such as the time delay between arrival of tracer in the ROIs and the sampling site. Methods: Data from eight ROIs placed about images of the myocardium were coupled by the parameters describing the metabolite concentration in the blood. The method was evaluated by comparing estimates of k2 made using the coupled region method and the standard process of fitting data from each region separately. In addition, comparisons were made between estimates of k2 and measured myocardial oxygen consumption. Results: Very little change in mean values of k2 was obtained. The variances, however, were reduced by an average of 37%, compared to the standard method, when the common parameters were not constrained. When the values of the common metabolite parameters were constrained to values previously measured, the average variance in estimates of k2 was reduced by 30%. Conclusion: We have demonstrated that the use of this technique can significantly increase the precision of estimates of myocardial oxygen consumption utilizing 11C-acetate PET images. More precise estimates of such quantities can facilitate detection of small regional and/or temporal physiological changes measured with PET. Furthermore, this method can be utilized whenever it is known a priori that one or more kinetic model parameters has the same value for every set of ROI data.

KW - carbon-11-acetate

KW - kinetic modeling

KW - PET

UR - http://www.scopus.com/inward/record.url?scp=0027934725&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027934725&partnerID=8YFLogxK

M3 - Article

C2 - 8046480

AN - SCOPUS:0027934725

VL - 35

SP - 1286

EP - 1291

JO - Journal of Nuclear Medicine

JF - Journal of Nuclear Medicine

SN - 0161-5505

IS - 8

ER -