Multichannel CT imaging of orthopedic hardware and implants

Research output: Contribution to journalArticle

44 Citations (Scopus)

Abstract

The introduction of multichannel CT scanners provides both radiologists and surgeons with a new tool to image patients with orthopedic hardware. The key parameters that have made it possible to image the implants and the surrounding bone with multichannel CT are the higher available technical factors (kVp and mAs) coupled with the ability to acquire thin slices over a large scan region. These properties make it possible to produce high-quality multiplanar reformations that facilitate visualization of the orthopedic device and the surrounding bone. An important consideration for multichannel CT imaging of hardware is the reduction of cone beam artifacts caused by the geometry of multichannel CT scanners. This artifact is reduced by using a narrower x-ray beam collimation and a low pitch setting. This article discusses CT scan parameters and image postprocessing used at our institution and illustrates common clinical problems encountered when imaging implanted orthopedic devices. These include fracture healing, loosening of joint prostheses, evaluation of particle disease, and the use of CT for preoperative planning in revision arthroplasty.

Original languageEnglish
Pages (from-to)86-97
Number of pages12
JournalSeminars in Musculoskeletal Radiology
Volume10
Issue number1
DOIs
StatePublished - Feb 2006

Fingerprint

Orthopedics
Artifacts
Joint Prosthesis
Bone and Bones
Equipment and Supplies
Fracture Healing
Arthroplasty
X-Rays
Radiologists
Surgeons

Keywords

  • Bone
  • CT
  • Joint prosthesis
  • Prostheses and implants
  • X-ray computed tomography

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Orthopedics and Sports Medicine
  • Surgery

Cite this

@article{7a92b8477c5b4729bf18f5c775309ee8,
title = "Multichannel CT imaging of orthopedic hardware and implants",
abstract = "The introduction of multichannel CT scanners provides both radiologists and surgeons with a new tool to image patients with orthopedic hardware. The key parameters that have made it possible to image the implants and the surrounding bone with multichannel CT are the higher available technical factors (kVp and mAs) coupled with the ability to acquire thin slices over a large scan region. These properties make it possible to produce high-quality multiplanar reformations that facilitate visualization of the orthopedic device and the surrounding bone. An important consideration for multichannel CT imaging of hardware is the reduction of cone beam artifacts caused by the geometry of multichannel CT scanners. This artifact is reduced by using a narrower x-ray beam collimation and a low pitch setting. This article discusses CT scan parameters and image postprocessing used at our institution and illustrates common clinical problems encountered when imaging implanted orthopedic devices. These include fracture healing, loosening of joint prostheses, evaluation of particle disease, and the use of CT for preoperative planning in revision arthroplasty.",
keywords = "Bone, CT, Joint prosthesis, Prostheses and implants, X-ray computed tomography",
author = "Kenneth Buckwalter and J. Parr and Robert Choplin and William Capello",
year = "2006",
month = "2",
doi = "10.1055/s-2006-934219",
language = "English",
volume = "10",
pages = "86--97",
journal = "Seminars in Musculoskeletal Radiology",
issn = "1089-7860",
publisher = "Thieme Medical Publishers",
number = "1",

}

TY - JOUR

T1 - Multichannel CT imaging of orthopedic hardware and implants

AU - Buckwalter, Kenneth

AU - Parr, J.

AU - Choplin, Robert

AU - Capello, William

PY - 2006/2

Y1 - 2006/2

N2 - The introduction of multichannel CT scanners provides both radiologists and surgeons with a new tool to image patients with orthopedic hardware. The key parameters that have made it possible to image the implants and the surrounding bone with multichannel CT are the higher available technical factors (kVp and mAs) coupled with the ability to acquire thin slices over a large scan region. These properties make it possible to produce high-quality multiplanar reformations that facilitate visualization of the orthopedic device and the surrounding bone. An important consideration for multichannel CT imaging of hardware is the reduction of cone beam artifacts caused by the geometry of multichannel CT scanners. This artifact is reduced by using a narrower x-ray beam collimation and a low pitch setting. This article discusses CT scan parameters and image postprocessing used at our institution and illustrates common clinical problems encountered when imaging implanted orthopedic devices. These include fracture healing, loosening of joint prostheses, evaluation of particle disease, and the use of CT for preoperative planning in revision arthroplasty.

AB - The introduction of multichannel CT scanners provides both radiologists and surgeons with a new tool to image patients with orthopedic hardware. The key parameters that have made it possible to image the implants and the surrounding bone with multichannel CT are the higher available technical factors (kVp and mAs) coupled with the ability to acquire thin slices over a large scan region. These properties make it possible to produce high-quality multiplanar reformations that facilitate visualization of the orthopedic device and the surrounding bone. An important consideration for multichannel CT imaging of hardware is the reduction of cone beam artifacts caused by the geometry of multichannel CT scanners. This artifact is reduced by using a narrower x-ray beam collimation and a low pitch setting. This article discusses CT scan parameters and image postprocessing used at our institution and illustrates common clinical problems encountered when imaging implanted orthopedic devices. These include fracture healing, loosening of joint prostheses, evaluation of particle disease, and the use of CT for preoperative planning in revision arthroplasty.

KW - Bone

KW - CT

KW - Joint prosthesis

KW - Prostheses and implants

KW - X-ray computed tomography

UR - http://www.scopus.com/inward/record.url?scp=33745929920&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33745929920&partnerID=8YFLogxK

U2 - 10.1055/s-2006-934219

DO - 10.1055/s-2006-934219

M3 - Article

VL - 10

SP - 86

EP - 97

JO - Seminars in Musculoskeletal Radiology

JF - Seminars in Musculoskeletal Radiology

SN - 1089-7860

IS - 1

ER -