Nondestructive analysis of urinary calculi using micro computed tomography

Chad A. Zarse, James A. McAteer, Andre J. Sommer, Samuel C. Kim, Erin K. Hatt, James E. Lingeman, Andrew Evan, James Williams

Research output: Contribution to journalArticle

66 Citations (Scopus)

Abstract

Background: Micro computed tomography (micro CT) has been shown to provide exceptionally high quality imaging of the fine structural detail within urinary calculi. We tested the idea that micro CT might also be used to identify the mineral composition of urinary stones non-destructively. Methods: Micro CT x-ray attenuation values were measured for mineral that was positively identified by infrared microspectroscopy (FT-IR). To do this, human urinary stones were sectioned with a diamond wire saw. The cut surface was explored by FT-IR and regions of pure mineral were evaluated by micro CT to correlate x-ray attenuation values with mineral content. Additionally, intact stones were imaged with micro CT to visualize internal morphology and map the distribution of specific mineral components in 3-D. Results: Micro CT images taken just beneath the cut surface of urinary stones showed excellent resolution of structural detail that could be correlated with structure visible in the optical image mode of FT-IR. Regions of pure mineral were not difficult to find by FT-IR for most stones and such regions could be localized on micro CT images of the cut surface. This was not true, however, for two brushite stones tested; in these, brushite was closely intermixed with calcium oxalate. Micro CT x-ray attenuation values were collected for six minerals that could be found in regions that appeared to be pure, including uric acid (3515 - 4995 micro CT attenuation units, AU), struvite (7242 - 7969 AU), cystine (8619 - 9921 AU), calcium oxalate dihydrate (13815 - 15797 AU), calcium oxalate monohydrate (16297 - 18449 AU), and hydroxyapatite (21144 - 23121 AU). These AU values did not overlap. Analysis of intact stones showed excellent resolution of structural detail and could discriminate multiple mineral types within heterogeneous stones. Conclusions: Micro CT gives excellent structural detail of urinary stones, and these results demonstrate the feasibility of identifying and localizing most of the common mineral types found in urinary calculi using laboratory CT.

Original languageEnglish
Article number15
JournalBMC Urology
Volume4
DOIs
StatePublished - Dec 13 2004

Fingerprint

Urinary Calculi
Minerals
Tomography
Calcium Oxalate
X-Rays
Diamond
Cystine
Durapatite
Uric Acid

ASJC Scopus subject areas

  • Medicine(all)
  • Reproductive Medicine

Cite this

Zarse, C. A., McAteer, J. A., Sommer, A. J., Kim, S. C., Hatt, E. K., Lingeman, J. E., ... Williams, J. (2004). Nondestructive analysis of urinary calculi using micro computed tomography. BMC Urology, 4, [15]. https://doi.org/10.1186/1471-2490-4-15

Nondestructive analysis of urinary calculi using micro computed tomography. / Zarse, Chad A.; McAteer, James A.; Sommer, Andre J.; Kim, Samuel C.; Hatt, Erin K.; Lingeman, James E.; Evan, Andrew; Williams, James.

In: BMC Urology, Vol. 4, 15, 13.12.2004.

Research output: Contribution to journalArticle

Zarse CA, McAteer JA, Sommer AJ, Kim SC, Hatt EK, Lingeman JE et al. Nondestructive analysis of urinary calculi using micro computed tomography. BMC Urology. 2004 Dec 13;4. 15. https://doi.org/10.1186/1471-2490-4-15
Zarse, Chad A. ; McAteer, James A. ; Sommer, Andre J. ; Kim, Samuel C. ; Hatt, Erin K. ; Lingeman, James E. ; Evan, Andrew ; Williams, James. / Nondestructive analysis of urinary calculi using micro computed tomography. In: BMC Urology. 2004 ; Vol. 4.
@article{498f6840b48146039c84c70a4fd5c79c,
title = "Nondestructive analysis of urinary calculi using micro computed tomography",
abstract = "Background: Micro computed tomography (micro CT) has been shown to provide exceptionally high quality imaging of the fine structural detail within urinary calculi. We tested the idea that micro CT might also be used to identify the mineral composition of urinary stones non-destructively. Methods: Micro CT x-ray attenuation values were measured for mineral that was positively identified by infrared microspectroscopy (FT-IR). To do this, human urinary stones were sectioned with a diamond wire saw. The cut surface was explored by FT-IR and regions of pure mineral were evaluated by micro CT to correlate x-ray attenuation values with mineral content. Additionally, intact stones were imaged with micro CT to visualize internal morphology and map the distribution of specific mineral components in 3-D. Results: Micro CT images taken just beneath the cut surface of urinary stones showed excellent resolution of structural detail that could be correlated with structure visible in the optical image mode of FT-IR. Regions of pure mineral were not difficult to find by FT-IR for most stones and such regions could be localized on micro CT images of the cut surface. This was not true, however, for two brushite stones tested; in these, brushite was closely intermixed with calcium oxalate. Micro CT x-ray attenuation values were collected for six minerals that could be found in regions that appeared to be pure, including uric acid (3515 - 4995 micro CT attenuation units, AU), struvite (7242 - 7969 AU), cystine (8619 - 9921 AU), calcium oxalate dihydrate (13815 - 15797 AU), calcium oxalate monohydrate (16297 - 18449 AU), and hydroxyapatite (21144 - 23121 AU). These AU values did not overlap. Analysis of intact stones showed excellent resolution of structural detail and could discriminate multiple mineral types within heterogeneous stones. Conclusions: Micro CT gives excellent structural detail of urinary stones, and these results demonstrate the feasibility of identifying and localizing most of the common mineral types found in urinary calculi using laboratory CT.",
author = "Zarse, {Chad A.} and McAteer, {James A.} and Sommer, {Andre J.} and Kim, {Samuel C.} and Hatt, {Erin K.} and Lingeman, {James E.} and Andrew Evan and James Williams",
year = "2004",
month = "12",
day = "13",
doi = "10.1186/1471-2490-4-15",
language = "English",
volume = "4",
journal = "BMC Urology",
issn = "1471-2490",
publisher = "BioMed Central",

}

TY - JOUR

T1 - Nondestructive analysis of urinary calculi using micro computed tomography

AU - Zarse, Chad A.

AU - McAteer, James A.

AU - Sommer, Andre J.

AU - Kim, Samuel C.

AU - Hatt, Erin K.

AU - Lingeman, James E.

AU - Evan, Andrew

AU - Williams, James

PY - 2004/12/13

Y1 - 2004/12/13

N2 - Background: Micro computed tomography (micro CT) has been shown to provide exceptionally high quality imaging of the fine structural detail within urinary calculi. We tested the idea that micro CT might also be used to identify the mineral composition of urinary stones non-destructively. Methods: Micro CT x-ray attenuation values were measured for mineral that was positively identified by infrared microspectroscopy (FT-IR). To do this, human urinary stones were sectioned with a diamond wire saw. The cut surface was explored by FT-IR and regions of pure mineral were evaluated by micro CT to correlate x-ray attenuation values with mineral content. Additionally, intact stones were imaged with micro CT to visualize internal morphology and map the distribution of specific mineral components in 3-D. Results: Micro CT images taken just beneath the cut surface of urinary stones showed excellent resolution of structural detail that could be correlated with structure visible in the optical image mode of FT-IR. Regions of pure mineral were not difficult to find by FT-IR for most stones and such regions could be localized on micro CT images of the cut surface. This was not true, however, for two brushite stones tested; in these, brushite was closely intermixed with calcium oxalate. Micro CT x-ray attenuation values were collected for six minerals that could be found in regions that appeared to be pure, including uric acid (3515 - 4995 micro CT attenuation units, AU), struvite (7242 - 7969 AU), cystine (8619 - 9921 AU), calcium oxalate dihydrate (13815 - 15797 AU), calcium oxalate monohydrate (16297 - 18449 AU), and hydroxyapatite (21144 - 23121 AU). These AU values did not overlap. Analysis of intact stones showed excellent resolution of structural detail and could discriminate multiple mineral types within heterogeneous stones. Conclusions: Micro CT gives excellent structural detail of urinary stones, and these results demonstrate the feasibility of identifying and localizing most of the common mineral types found in urinary calculi using laboratory CT.

AB - Background: Micro computed tomography (micro CT) has been shown to provide exceptionally high quality imaging of the fine structural detail within urinary calculi. We tested the idea that micro CT might also be used to identify the mineral composition of urinary stones non-destructively. Methods: Micro CT x-ray attenuation values were measured for mineral that was positively identified by infrared microspectroscopy (FT-IR). To do this, human urinary stones were sectioned with a diamond wire saw. The cut surface was explored by FT-IR and regions of pure mineral were evaluated by micro CT to correlate x-ray attenuation values with mineral content. Additionally, intact stones were imaged with micro CT to visualize internal morphology and map the distribution of specific mineral components in 3-D. Results: Micro CT images taken just beneath the cut surface of urinary stones showed excellent resolution of structural detail that could be correlated with structure visible in the optical image mode of FT-IR. Regions of pure mineral were not difficult to find by FT-IR for most stones and such regions could be localized on micro CT images of the cut surface. This was not true, however, for two brushite stones tested; in these, brushite was closely intermixed with calcium oxalate. Micro CT x-ray attenuation values were collected for six minerals that could be found in regions that appeared to be pure, including uric acid (3515 - 4995 micro CT attenuation units, AU), struvite (7242 - 7969 AU), cystine (8619 - 9921 AU), calcium oxalate dihydrate (13815 - 15797 AU), calcium oxalate monohydrate (16297 - 18449 AU), and hydroxyapatite (21144 - 23121 AU). These AU values did not overlap. Analysis of intact stones showed excellent resolution of structural detail and could discriminate multiple mineral types within heterogeneous stones. Conclusions: Micro CT gives excellent structural detail of urinary stones, and these results demonstrate the feasibility of identifying and localizing most of the common mineral types found in urinary calculi using laboratory CT.

UR - http://www.scopus.com/inward/record.url?scp=33751376905&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33751376905&partnerID=8YFLogxK

U2 - 10.1186/1471-2490-4-15

DO - 10.1186/1471-2490-4-15

M3 - Article

VL - 4

JO - BMC Urology

JF - BMC Urology

SN - 1471-2490

M1 - 15

ER -