Nonunion of a pertrochanteric femur fracture due to a low-velocity gunshot.

Brian J. Evanson, Brian Mullis, Jeffrey O. Anglen

Research output: Contribution to journalArticle

Abstract

The treatment of nonunions often can be a complex and challenging venture. This case report details the treatment of a young patient's pertrochanteric femoral nonunion due to a low-velocity gunshot. Fracture fixation and union were attempted with various implants, including a sliding hip screw, blade plate, and proximal femoral locking plate; however, all eventually failed. Successful union ultimately was obtained only after use of a cephalomedullary nail. There have been few reports in the literature on the failure of proximal femoral locking plates in the treatment of pertrochanteric femur fractures, though much has been published regarding the sliding hip screw and blade plate. Multiple options for use in nonunion surgery were used and discussed in this case, such as autogenous bone graft, bone morphogenic protein, and implantable bone stimulators.

Original languageEnglish (US)
JournalAmerican journal of orthopedics (Belle Mead, N.J.)
Volume40
Issue number1
StatePublished - Jan 2011
Externally publishedYes

Fingerprint

Thigh
Femur
Hip
Bone and Bones
Fracture Fixation
Nails
Therapeutics
Transplants
Proteins

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Nonunion of a pertrochanteric femur fracture due to a low-velocity gunshot. / Evanson, Brian J.; Mullis, Brian; Anglen, Jeffrey O.

In: American journal of orthopedics (Belle Mead, N.J.), Vol. 40, No. 1, 01.2011.

Research output: Contribution to journalArticle

@article{427409f73c134239b47f334377461003,
title = "Nonunion of a pertrochanteric femur fracture due to a low-velocity gunshot.",
abstract = "The treatment of nonunions often can be a complex and challenging venture. This case report details the treatment of a young patient's pertrochanteric femoral nonunion due to a low-velocity gunshot. Fracture fixation and union were attempted with various implants, including a sliding hip screw, blade plate, and proximal femoral locking plate; however, all eventually failed. Successful union ultimately was obtained only after use of a cephalomedullary nail. There have been few reports in the literature on the failure of proximal femoral locking plates in the treatment of pertrochanteric femur fractures, though much has been published regarding the sliding hip screw and blade plate. Multiple options for use in nonunion surgery were used and discussed in this case, such as autogenous bone graft, bone morphogenic protein, and implantable bone stimulators.",
author = "Evanson, {Brian J.} and Brian Mullis and Anglen, {Jeffrey O.}",
year = "2011",
month = "1",
language = "English (US)",
volume = "40",
journal = "American Journal of Orthopedics",
issn = "1078-4519",
publisher = "Quadrant Healthcom Inc.",
number = "1",

}

TY - JOUR

T1 - Nonunion of a pertrochanteric femur fracture due to a low-velocity gunshot.

AU - Evanson, Brian J.

AU - Mullis, Brian

AU - Anglen, Jeffrey O.

PY - 2011/1

Y1 - 2011/1

N2 - The treatment of nonunions often can be a complex and challenging venture. This case report details the treatment of a young patient's pertrochanteric femoral nonunion due to a low-velocity gunshot. Fracture fixation and union were attempted with various implants, including a sliding hip screw, blade plate, and proximal femoral locking plate; however, all eventually failed. Successful union ultimately was obtained only after use of a cephalomedullary nail. There have been few reports in the literature on the failure of proximal femoral locking plates in the treatment of pertrochanteric femur fractures, though much has been published regarding the sliding hip screw and blade plate. Multiple options for use in nonunion surgery were used and discussed in this case, such as autogenous bone graft, bone morphogenic protein, and implantable bone stimulators.

AB - The treatment of nonunions often can be a complex and challenging venture. This case report details the treatment of a young patient's pertrochanteric femoral nonunion due to a low-velocity gunshot. Fracture fixation and union were attempted with various implants, including a sliding hip screw, blade plate, and proximal femoral locking plate; however, all eventually failed. Successful union ultimately was obtained only after use of a cephalomedullary nail. There have been few reports in the literature on the failure of proximal femoral locking plates in the treatment of pertrochanteric femur fractures, though much has been published regarding the sliding hip screw and blade plate. Multiple options for use in nonunion surgery were used and discussed in this case, such as autogenous bone graft, bone morphogenic protein, and implantable bone stimulators.

UR - http://www.scopus.com/inward/record.url?scp=80054841323&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=80054841323&partnerID=8YFLogxK

M3 - Article

VL - 40

JO - American Journal of Orthopedics

JF - American Journal of Orthopedics

SN - 1078-4519

IS - 1