Patterns of patient specific dosimetry in total body irradiation

Yuichi Akino, Kevin P. McMullen, Indra J. Das

Research output: Contribution to journalArticle

7 Scopus citations

Abstract

Purpose: Total body irradiation (TBI) has been used for bone marrow transplant for hematologic and immune deficiency conditions. The goal of TBI is to deliver a homogeneous dose to the entire body, with a generally accepted range of dose uniformity being within ±10 of the prescribed dose. The moving table technique for TBI could make dose uniform in whole body by adjusting couch speed. However, it is difficult to accurately estimate the actual dose by calculation and hence in vivo dosimetry (IVD) is routinely performed. Here, the authors present patterns of patient-specific IVD in 161 TBI patients treated at our institution. Methods: Cobalt-60 teletherapy unit (Model C9 Cobalt-60 teletherapy unit, Picker X-ray Corporation) with customized moving bed (SITI Industrial Products, Inc., Fishers, IN) were used for TBI treatment. During treatment, OneDoseTM (Sicel Technology, NC) Metal Oxide-silicon Semiconductor Field Effect Transistor detectors were placed at patient body surface; both entrance and exit side of the beam at patient head, neck, mediastinum, umbilicus, and knee to estimate midplane dose. When large differences (>10) between the prescribed and measured dose were observed, dose delivery was corrected for subsequent fractions by the adjustment of couch speed andor bolus placement. Under IRB exempt status, the authors retrospectively analyzed the treatment records of 161 patients who received TBI treatment between 2006 and 2011. Results: Across the entire cohort, the median ± SD (range) percent variance between calculated and measured dose for head, neck, mediastinum, umbilicus, and knee was -2.3 ± 10.2 (-66.2 to 35.3), 1.1 ± 11.5 (-62.2 to 40.3), -1.9 ± 9.5 (-66.4 to 46.6), -1.1 ± 7.2 (-35.2 to 42.9), and 3.4 ± 12.2 (-47.9 to 108.5), respectively. More than half of treatments were within ±10 of the prescribed dose for all anatomical regions. For 80 of treatments (10-90), dose at the umbilicus was within ±10. However, some large differences greater than 35 were also found at several points. For one case, the knee received double the prescribed dose. When the dose differences for multiple fractions were averaged, compliance (±10) between the prescription and measured dose was improved compared to the dose difference of the first single fraction, for example, as at umbilicus, which improved from 83.9 to 98.5. Conclusions: Actual dose measurement analysis of TBI patients revealed a potentially wide variance from the calculated dose. Based from their IVD method for TBI using Cobalt-60 irradiator and moving table, ±10 over entire body is hard to achieve. However, it can be significantly improved with immediate feedback after the first fraction prior to subsequent treatments.

Original languageEnglish (US)
Article number041719
JournalMedical physics
Volume40
Issue number4
DOIs
StatePublished - Apr 2013

Keywords

  • in vivo dosimetry
  • total body irradiation

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint Dive into the research topics of 'Patterns of patient specific dosimetry in total body irradiation'. Together they form a unique fingerprint.

  • Cite this