Abstract

Purpose: Restrictive strabismus is a common and difficult problem confronted by strabismologists. Several materials have been used to minimize the formation of adhesions after strabismus surgery with varying degrees of success. Polydiaxonon (PDS, Ethicon) is an absorbable, nontoxic, nonporous material. We used it as 25 and 50 μm thick sleeves to study its effectiveness in the prevention of adhesions. Method: Eight eyes of four adult New Zealand White rabbits were used. To simulate the adhesions, a raw scleral bed was created under the superior rectus insertion in study animals and the muscle capsule facing the sclera was opened. Four study eyes had PDS sleeves inserted around the superior rectus; the other four served as controls. After 4 months the animals were killed. The surgical sites were inspected for adhesions. Light microscopy was also performed. Results: Virtually no adhesion formation was noted in the study eyes. In the control group, however, dense adhesions were seen. Light microscopy confirmed these results. No significant amount of foreign material was found. There was no toxicity resulting from PDS. Conclusions: This demonstrated nearly complete prevention of adhesions in the rabbit model. PDS sleeves appear to have potential in surgery for restrictive strabismus.

Original languageEnglish (US)
Pages (from-to)214-217
Number of pages4
JournalJournal of AAPOS
Volume2
Issue number4
StatePublished - 1998

Fingerprint

Strabismus
Rabbits
Microscopy
Light
Sclera
Capsules
Muscles
Control Groups
poly-4-dioxan-2-one

ASJC Scopus subject areas

  • Ophthalmology

Cite this

Sondhi, N., Koseoglu, S. T., Bonnin, J., & Fahad, B. (1998). Polydiaxonon prevents adhesions in the rabbit model: A pilot report. Journal of AAPOS, 2(4), 214-217.

Polydiaxonon prevents adhesions in the rabbit model : A pilot report. / Sondhi, Naval; Koseoglu, Selim T.; Bonnin, Jose; Fahad, Badia.

In: Journal of AAPOS, Vol. 2, No. 4, 1998, p. 214-217.

Research output: Contribution to journalArticle

Sondhi, N, Koseoglu, ST, Bonnin, J & Fahad, B 1998, 'Polydiaxonon prevents adhesions in the rabbit model: A pilot report', Journal of AAPOS, vol. 2, no. 4, pp. 214-217.
Sondhi, Naval ; Koseoglu, Selim T. ; Bonnin, Jose ; Fahad, Badia. / Polydiaxonon prevents adhesions in the rabbit model : A pilot report. In: Journal of AAPOS. 1998 ; Vol. 2, No. 4. pp. 214-217.
@article{991d934689a74101baf8eb4883ad43da,
title = "Polydiaxonon prevents adhesions in the rabbit model: A pilot report",
abstract = "Purpose: Restrictive strabismus is a common and difficult problem confronted by strabismologists. Several materials have been used to minimize the formation of adhesions after strabismus surgery with varying degrees of success. Polydiaxonon (PDS, Ethicon) is an absorbable, nontoxic, nonporous material. We used it as 25 and 50 μm thick sleeves to study its effectiveness in the prevention of adhesions. Method: Eight eyes of four adult New Zealand White rabbits were used. To simulate the adhesions, a raw scleral bed was created under the superior rectus insertion in study animals and the muscle capsule facing the sclera was opened. Four study eyes had PDS sleeves inserted around the superior rectus; the other four served as controls. After 4 months the animals were killed. The surgical sites were inspected for adhesions. Light microscopy was also performed. Results: Virtually no adhesion formation was noted in the study eyes. In the control group, however, dense adhesions were seen. Light microscopy confirmed these results. No significant amount of foreign material was found. There was no toxicity resulting from PDS. Conclusions: This demonstrated nearly complete prevention of adhesions in the rabbit model. PDS sleeves appear to have potential in surgery for restrictive strabismus.",
author = "Naval Sondhi and Koseoglu, {Selim T.} and Jose Bonnin and Badia Fahad",
year = "1998",
language = "English (US)",
volume = "2",
pages = "214--217",
journal = "Journal of AAPOS",
issn = "1091-8531",
publisher = "Mosby Inc.",
number = "4",

}

TY - JOUR

T1 - Polydiaxonon prevents adhesions in the rabbit model

T2 - A pilot report

AU - Sondhi, Naval

AU - Koseoglu, Selim T.

AU - Bonnin, Jose

AU - Fahad, Badia

PY - 1998

Y1 - 1998

N2 - Purpose: Restrictive strabismus is a common and difficult problem confronted by strabismologists. Several materials have been used to minimize the formation of adhesions after strabismus surgery with varying degrees of success. Polydiaxonon (PDS, Ethicon) is an absorbable, nontoxic, nonporous material. We used it as 25 and 50 μm thick sleeves to study its effectiveness in the prevention of adhesions. Method: Eight eyes of four adult New Zealand White rabbits were used. To simulate the adhesions, a raw scleral bed was created under the superior rectus insertion in study animals and the muscle capsule facing the sclera was opened. Four study eyes had PDS sleeves inserted around the superior rectus; the other four served as controls. After 4 months the animals were killed. The surgical sites were inspected for adhesions. Light microscopy was also performed. Results: Virtually no adhesion formation was noted in the study eyes. In the control group, however, dense adhesions were seen. Light microscopy confirmed these results. No significant amount of foreign material was found. There was no toxicity resulting from PDS. Conclusions: This demonstrated nearly complete prevention of adhesions in the rabbit model. PDS sleeves appear to have potential in surgery for restrictive strabismus.

AB - Purpose: Restrictive strabismus is a common and difficult problem confronted by strabismologists. Several materials have been used to minimize the formation of adhesions after strabismus surgery with varying degrees of success. Polydiaxonon (PDS, Ethicon) is an absorbable, nontoxic, nonporous material. We used it as 25 and 50 μm thick sleeves to study its effectiveness in the prevention of adhesions. Method: Eight eyes of four adult New Zealand White rabbits were used. To simulate the adhesions, a raw scleral bed was created under the superior rectus insertion in study animals and the muscle capsule facing the sclera was opened. Four study eyes had PDS sleeves inserted around the superior rectus; the other four served as controls. After 4 months the animals were killed. The surgical sites were inspected for adhesions. Light microscopy was also performed. Results: Virtually no adhesion formation was noted in the study eyes. In the control group, however, dense adhesions were seen. Light microscopy confirmed these results. No significant amount of foreign material was found. There was no toxicity resulting from PDS. Conclusions: This demonstrated nearly complete prevention of adhesions in the rabbit model. PDS sleeves appear to have potential in surgery for restrictive strabismus.

UR - http://www.scopus.com/inward/record.url?scp=0032130889&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032130889&partnerID=8YFLogxK

M3 - Article

C2 - 10532739

AN - SCOPUS:0032130889

VL - 2

SP - 214

EP - 217

JO - Journal of AAPOS

JF - Journal of AAPOS

SN - 1091-8531

IS - 4

ER -