Predictors of depth of maximal insertion at double-balloon enteroscopy

Mouen Khashab, Debra J. Helper, Cynthia S. Johnson, Michael V. Chiorean

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

The aim of this study was to determine the factors predictive of the depth of maximal insertion (DMI) at double-balloon enteroscopy (DBE). Eligible patients from the DBE database at our institution were stratified based on their anterograde or retrograde approach. The factors predictive of the DMI were calculated using ANOVA, Spearman, univariate, and multivariate regression analysis. A total of 79 patients had 98 procedures, 67 anterograde and 31 retrograde. Fifty-eight (73%) had previous abdominal surgeries. The average anterograde DMI was 187.5 cm, retrograde 116.5 cm. In univariate regression analysis, a history of abdominal surgery and surgery excluding appendectomy were negative predictors of the DMI for both the anterograde and retrograde approaches (P<0.05). A history of bowel surgery and number of surgeries were negative predictive factors only for the anterograde approach (P<0.005). In multivariate analysis, the number of abdominal surgeries (anterograde) and any abdominal surgery (retrograde) were predictors of the DMI (P = 0.02 and P = 0.003, respectively). Patients with three or more surgeries had a significantly lower DMI than those with ≤1 (137 vs. 214 cm, P<0.001 for anterograde and 114 vs. 148 cm, P<0.001 for retrograde). There was no correlation between the DMI and age, BMI, date of the study, or procedure duration for either approach. Previous abdominal surgeries can significantly impact the DMI at DBE.

Original languageEnglish (US)
Pages (from-to)1391-1395
Number of pages5
JournalDigestive diseases and sciences
Volume55
Issue number5
DOIs
StatePublished - May 1 2010

Fingerprint

Double-Balloon Enteroscopy
Multivariate Analysis
Regression Analysis
Appendectomy
Analysis of Variance
Databases

Keywords

  • Deep enteroscopy
  • Depth of maximal insertion
  • Double-balloon enteroscopy

ASJC Scopus subject areas

  • Gastroenterology
  • Physiology

Cite this

Predictors of depth of maximal insertion at double-balloon enteroscopy. / Khashab, Mouen; Helper, Debra J.; Johnson, Cynthia S.; Chiorean, Michael V.

In: Digestive diseases and sciences, Vol. 55, No. 5, 01.05.2010, p. 1391-1395.

Research output: Contribution to journalArticle

Khashab, Mouen ; Helper, Debra J. ; Johnson, Cynthia S. ; Chiorean, Michael V. / Predictors of depth of maximal insertion at double-balloon enteroscopy. In: Digestive diseases and sciences. 2010 ; Vol. 55, No. 5. pp. 1391-1395.
@article{047f9c342a2a4ec3bca2c9ced20eb64e,
title = "Predictors of depth of maximal insertion at double-balloon enteroscopy",
abstract = "The aim of this study was to determine the factors predictive of the depth of maximal insertion (DMI) at double-balloon enteroscopy (DBE). Eligible patients from the DBE database at our institution were stratified based on their anterograde or retrograde approach. The factors predictive of the DMI were calculated using ANOVA, Spearman, univariate, and multivariate regression analysis. A total of 79 patients had 98 procedures, 67 anterograde and 31 retrograde. Fifty-eight (73{\%}) had previous abdominal surgeries. The average anterograde DMI was 187.5 cm, retrograde 116.5 cm. In univariate regression analysis, a history of abdominal surgery and surgery excluding appendectomy were negative predictors of the DMI for both the anterograde and retrograde approaches (P<0.05). A history of bowel surgery and number of surgeries were negative predictive factors only for the anterograde approach (P<0.005). In multivariate analysis, the number of abdominal surgeries (anterograde) and any abdominal surgery (retrograde) were predictors of the DMI (P = 0.02 and P = 0.003, respectively). Patients with three or more surgeries had a significantly lower DMI than those with ≤1 (137 vs. 214 cm, P<0.001 for anterograde and 114 vs. 148 cm, P<0.001 for retrograde). There was no correlation between the DMI and age, BMI, date of the study, or procedure duration for either approach. Previous abdominal surgeries can significantly impact the DMI at DBE.",
keywords = "Deep enteroscopy, Depth of maximal insertion, Double-balloon enteroscopy",
author = "Mouen Khashab and Helper, {Debra J.} and Johnson, {Cynthia S.} and Chiorean, {Michael V.}",
year = "2010",
month = "5",
day = "1",
doi = "10.1007/s10620-009-0849-6",
language = "English (US)",
volume = "55",
pages = "1391--1395",
journal = "Digestive Diseases and Sciences",
issn = "0163-2116",
publisher = "Springer New York",
number = "5",

}

TY - JOUR

T1 - Predictors of depth of maximal insertion at double-balloon enteroscopy

AU - Khashab, Mouen

AU - Helper, Debra J.

AU - Johnson, Cynthia S.

AU - Chiorean, Michael V.

PY - 2010/5/1

Y1 - 2010/5/1

N2 - The aim of this study was to determine the factors predictive of the depth of maximal insertion (DMI) at double-balloon enteroscopy (DBE). Eligible patients from the DBE database at our institution were stratified based on their anterograde or retrograde approach. The factors predictive of the DMI were calculated using ANOVA, Spearman, univariate, and multivariate regression analysis. A total of 79 patients had 98 procedures, 67 anterograde and 31 retrograde. Fifty-eight (73%) had previous abdominal surgeries. The average anterograde DMI was 187.5 cm, retrograde 116.5 cm. In univariate regression analysis, a history of abdominal surgery and surgery excluding appendectomy were negative predictors of the DMI for both the anterograde and retrograde approaches (P<0.05). A history of bowel surgery and number of surgeries were negative predictive factors only for the anterograde approach (P<0.005). In multivariate analysis, the number of abdominal surgeries (anterograde) and any abdominal surgery (retrograde) were predictors of the DMI (P = 0.02 and P = 0.003, respectively). Patients with three or more surgeries had a significantly lower DMI than those with ≤1 (137 vs. 214 cm, P<0.001 for anterograde and 114 vs. 148 cm, P<0.001 for retrograde). There was no correlation between the DMI and age, BMI, date of the study, or procedure duration for either approach. Previous abdominal surgeries can significantly impact the DMI at DBE.

AB - The aim of this study was to determine the factors predictive of the depth of maximal insertion (DMI) at double-balloon enteroscopy (DBE). Eligible patients from the DBE database at our institution were stratified based on their anterograde or retrograde approach. The factors predictive of the DMI were calculated using ANOVA, Spearman, univariate, and multivariate regression analysis. A total of 79 patients had 98 procedures, 67 anterograde and 31 retrograde. Fifty-eight (73%) had previous abdominal surgeries. The average anterograde DMI was 187.5 cm, retrograde 116.5 cm. In univariate regression analysis, a history of abdominal surgery and surgery excluding appendectomy were negative predictors of the DMI for both the anterograde and retrograde approaches (P<0.05). A history of bowel surgery and number of surgeries were negative predictive factors only for the anterograde approach (P<0.005). In multivariate analysis, the number of abdominal surgeries (anterograde) and any abdominal surgery (retrograde) were predictors of the DMI (P = 0.02 and P = 0.003, respectively). Patients with three or more surgeries had a significantly lower DMI than those with ≤1 (137 vs. 214 cm, P<0.001 for anterograde and 114 vs. 148 cm, P<0.001 for retrograde). There was no correlation between the DMI and age, BMI, date of the study, or procedure duration for either approach. Previous abdominal surgeries can significantly impact the DMI at DBE.

KW - Deep enteroscopy

KW - Depth of maximal insertion

KW - Double-balloon enteroscopy

UR - http://www.scopus.com/inward/record.url?scp=77953648155&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77953648155&partnerID=8YFLogxK

U2 - 10.1007/s10620-009-0849-6

DO - 10.1007/s10620-009-0849-6

M3 - Article

C2 - 19513839

AN - SCOPUS:77953648155

VL - 55

SP - 1391

EP - 1395

JO - Digestive Diseases and Sciences

JF - Digestive Diseases and Sciences

SN - 0163-2116

IS - 5

ER -