Abstract
This study compared silver penetration in the adhesive interface among four versions of adhesives from the same manufacturer: OptiBond FL, OptiBond Solo Plus, OptiBond Solo Plus Dual Cure, and OptiBond Solo Plus Self-Etch, when coupled with dual-cured composite, CoreRestore 2 (Kerr). Twenty flat dentin surfaces were prepared using one of the adhesives and bonded with the composite, following the manufacturer's instructions. The surfaces were sectioned into 2-mm slabs and immersed in ammoniacal silver nitrate for 24 hours. Each specimen was exposed to a photodeveloping solution for eight hours and examined with a scanning electron microscope (SEM). The water permeable area occupied by the silver nitrate tracer was determined, and the relative weight of silver was analyzed by wavelength dispersive spectrometry (WDS). The OptiBond FL group had a significantly lower silver content than the other groups (p
Original language | English (US) |
---|---|
Pages (from-to) | 346-353 |
Number of pages | 8 |
Journal | Operative Dentistry |
Volume | 31 |
Issue number | 3 |
State | Published - May 2006 |
Fingerprint
ASJC Scopus subject areas
- Dentistry(all)
Cite this
Quantitative comparison of the water permeable zone among four types of dental adhesives used with a dual-cured composite. / Chang, Juhea; Platt, Jeffrey; Yi, Keewook; Cochran, Michael A.
In: Operative Dentistry, Vol. 31, No. 3, 05.2006, p. 346-353.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - Quantitative comparison of the water permeable zone among four types of dental adhesives used with a dual-cured composite
AU - Chang, Juhea
AU - Platt, Jeffrey
AU - Yi, Keewook
AU - Cochran, Michael A.
PY - 2006/5
Y1 - 2006/5
N2 - This study compared silver penetration in the adhesive interface among four versions of adhesives from the same manufacturer: OptiBond FL, OptiBond Solo Plus, OptiBond Solo Plus Dual Cure, and OptiBond Solo Plus Self-Etch, when coupled with dual-cured composite, CoreRestore 2 (Kerr). Twenty flat dentin surfaces were prepared using one of the adhesives and bonded with the composite, following the manufacturer's instructions. The surfaces were sectioned into 2-mm slabs and immersed in ammoniacal silver nitrate for 24 hours. Each specimen was exposed to a photodeveloping solution for eight hours and examined with a scanning electron microscope (SEM). The water permeable area occupied by the silver nitrate tracer was determined, and the relative weight of silver was analyzed by wavelength dispersive spectrometry (WDS). The OptiBond FL group had a significantly lower silver content than the other groups (p
AB - This study compared silver penetration in the adhesive interface among four versions of adhesives from the same manufacturer: OptiBond FL, OptiBond Solo Plus, OptiBond Solo Plus Dual Cure, and OptiBond Solo Plus Self-Etch, when coupled with dual-cured composite, CoreRestore 2 (Kerr). Twenty flat dentin surfaces were prepared using one of the adhesives and bonded with the composite, following the manufacturer's instructions. The surfaces were sectioned into 2-mm slabs and immersed in ammoniacal silver nitrate for 24 hours. Each specimen was exposed to a photodeveloping solution for eight hours and examined with a scanning electron microscope (SEM). The water permeable area occupied by the silver nitrate tracer was determined, and the relative weight of silver was analyzed by wavelength dispersive spectrometry (WDS). The OptiBond FL group had a significantly lower silver content than the other groups (p
UR - http://www.scopus.com/inward/record.url?scp=33745465839&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33745465839&partnerID=8YFLogxK
M3 - Article
C2 - 16802643
AN - SCOPUS:33745465839
VL - 31
SP - 346
EP - 353
JO - Operative Dentistry
JF - Operative Dentistry
SN - 0361-7734
IS - 3