Radiation safety considerations in proton aperture disposal

Priscilla K. Walker, Andrew C. Edwards, Indra J. Das, Peter A S Johnstone

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Beam shaping in scattered and uniform scanned proton beam therapy (PBT) is made commonly by brass apertures. Due to proton interactions, these devices become radioactive and could pose safety issues and radiation hazards. Nearly 2,000 patient-specific devices per year are used at Indiana University Cyclotron Operations (IUCO) and IU Health Proton Therapy Center (IUHPTC); these devices require proper guidelines for disposal. IUCO practice has been to store these apertures for at least 4 mo to allow for safe transfer to recycling contractors. The devices require decay in two staged secure locations, including at least 4 mo in a separate building, at which point half are ready for disposal. At 6 mo, 20-30% of apertures require further storage. This process requires significant space and manpower and should be considered in the design process for new clinical facilities. More widespread adoption of pencil beam or spot scanning nozzles may obviate this issue, as apertures then will no longer be necessary.

Original languageEnglish
Pages (from-to)523-527
Number of pages5
JournalHealth Physics
Volume106
Issue number4
DOIs
StatePublished - Apr 2014

Fingerprint

Protons
Proton Therapy
Radiation
Cyclotrons
Safety
Equipment and Supplies
Recycling
Guidelines
Health

Keywords

  • cyclotron
  • protons
  • radiation medical
  • radiation protection

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Health, Toxicology and Mutagenesis
  • Epidemiology

Cite this

Walker, P. K., Edwards, A. C., Das, I. J., & Johnstone, P. A. S. (2014). Radiation safety considerations in proton aperture disposal. Health Physics, 106(4), 523-527. https://doi.org/10.1097/HP.0b013e3182a2a725

Radiation safety considerations in proton aperture disposal. / Walker, Priscilla K.; Edwards, Andrew C.; Das, Indra J.; Johnstone, Peter A S.

In: Health Physics, Vol. 106, No. 4, 04.2014, p. 523-527.

Research output: Contribution to journalArticle

Walker, PK, Edwards, AC, Das, IJ & Johnstone, PAS 2014, 'Radiation safety considerations in proton aperture disposal', Health Physics, vol. 106, no. 4, pp. 523-527. https://doi.org/10.1097/HP.0b013e3182a2a725
Walker, Priscilla K. ; Edwards, Andrew C. ; Das, Indra J. ; Johnstone, Peter A S. / Radiation safety considerations in proton aperture disposal. In: Health Physics. 2014 ; Vol. 106, No. 4. pp. 523-527.
@article{b1014371545644c9aad5ef5a892435f4,
title = "Radiation safety considerations in proton aperture disposal",
abstract = "Beam shaping in scattered and uniform scanned proton beam therapy (PBT) is made commonly by brass apertures. Due to proton interactions, these devices become radioactive and could pose safety issues and radiation hazards. Nearly 2,000 patient-specific devices per year are used at Indiana University Cyclotron Operations (IUCO) and IU Health Proton Therapy Center (IUHPTC); these devices require proper guidelines for disposal. IUCO practice has been to store these apertures for at least 4 mo to allow for safe transfer to recycling contractors. The devices require decay in two staged secure locations, including at least 4 mo in a separate building, at which point half are ready for disposal. At 6 mo, 20-30{\%} of apertures require further storage. This process requires significant space and manpower and should be considered in the design process for new clinical facilities. More widespread adoption of pencil beam or spot scanning nozzles may obviate this issue, as apertures then will no longer be necessary.",
keywords = "cyclotron, protons, radiation medical, radiation protection",
author = "Walker, {Priscilla K.} and Edwards, {Andrew C.} and Das, {Indra J.} and Johnstone, {Peter A S}",
year = "2014",
month = "4",
doi = "10.1097/HP.0b013e3182a2a725",
language = "English",
volume = "106",
pages = "523--527",
journal = "Health Physics",
issn = "0017-9078",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

TY - JOUR

T1 - Radiation safety considerations in proton aperture disposal

AU - Walker, Priscilla K.

AU - Edwards, Andrew C.

AU - Das, Indra J.

AU - Johnstone, Peter A S

PY - 2014/4

Y1 - 2014/4

N2 - Beam shaping in scattered and uniform scanned proton beam therapy (PBT) is made commonly by brass apertures. Due to proton interactions, these devices become radioactive and could pose safety issues and radiation hazards. Nearly 2,000 patient-specific devices per year are used at Indiana University Cyclotron Operations (IUCO) and IU Health Proton Therapy Center (IUHPTC); these devices require proper guidelines for disposal. IUCO practice has been to store these apertures for at least 4 mo to allow for safe transfer to recycling contractors. The devices require decay in two staged secure locations, including at least 4 mo in a separate building, at which point half are ready for disposal. At 6 mo, 20-30% of apertures require further storage. This process requires significant space and manpower and should be considered in the design process for new clinical facilities. More widespread adoption of pencil beam or spot scanning nozzles may obviate this issue, as apertures then will no longer be necessary.

AB - Beam shaping in scattered and uniform scanned proton beam therapy (PBT) is made commonly by brass apertures. Due to proton interactions, these devices become radioactive and could pose safety issues and radiation hazards. Nearly 2,000 patient-specific devices per year are used at Indiana University Cyclotron Operations (IUCO) and IU Health Proton Therapy Center (IUHPTC); these devices require proper guidelines for disposal. IUCO practice has been to store these apertures for at least 4 mo to allow for safe transfer to recycling contractors. The devices require decay in two staged secure locations, including at least 4 mo in a separate building, at which point half are ready for disposal. At 6 mo, 20-30% of apertures require further storage. This process requires significant space and manpower and should be considered in the design process for new clinical facilities. More widespread adoption of pencil beam or spot scanning nozzles may obviate this issue, as apertures then will no longer be necessary.

KW - cyclotron

KW - protons

KW - radiation medical

KW - radiation protection

UR - http://www.scopus.com/inward/record.url?scp=84896881650&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84896881650&partnerID=8YFLogxK

U2 - 10.1097/HP.0b013e3182a2a725

DO - 10.1097/HP.0b013e3182a2a725

M3 - Article

VL - 106

SP - 523

EP - 527

JO - Health Physics

JF - Health Physics

SN - 0017-9078