Sampling requirements for dynamic cardiac PET studies using image-derived input functions

R. R. Raylman, J. M. Caraher, Gary Hutchins

Research output: Contribution to journalArticle

34 Citations (Scopus)

Abstract

The utilization of image-derived input functions is becoming common in quantitative PET studies of the heart. Consequently, imaging protocols must be designed to sample both blood and tissue concentrations adequately. Most clinical imaging protocols consist of a series of short initial scans to measure the rapid change in blood and tissue tracer concentration levels, followed by scans of gradually increasing length. The number of initial short scans must be matched to the shape of the input function. In this paper, noise-free simulation studies were performed to evaluate the effect of temporal sampling on estimates of the parameters of a two-compartment kinetic model. In addition, the consequences of varying tracer infusion length and timing were studied. The kinetic model parameters' bias decreased when infusion times were lengthened or sampling rates increased. Our results indicated that tracer infusions of 30 sec were best suited for these studies. Two currently employed clinical imaging protocols were then optimized for use with this infusion scheme. Ten initial scans with durations of 10 sec, or twenty of 5 sec length produced unbiased estimates of kinetic model parameters that describe myocardial physiology. Noisy simulations with the equivalent of one million events confirmed these results.

Original languageEnglish (US)
Pages (from-to)440-447
Number of pages8
JournalJournal of Nuclear Medicine
Volume34
Issue number3
StatePublished - 1993
Externally publishedYes

Fingerprint

Clinical Protocols
Noise

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology

Cite this

Sampling requirements for dynamic cardiac PET studies using image-derived input functions. / Raylman, R. R.; Caraher, J. M.; Hutchins, Gary.

In: Journal of Nuclear Medicine, Vol. 34, No. 3, 1993, p. 440-447.

Research output: Contribution to journalArticle

@article{b5e141eae4c14026af5768630da17cb3,
title = "Sampling requirements for dynamic cardiac PET studies using image-derived input functions",
abstract = "The utilization of image-derived input functions is becoming common in quantitative PET studies of the heart. Consequently, imaging protocols must be designed to sample both blood and tissue concentrations adequately. Most clinical imaging protocols consist of a series of short initial scans to measure the rapid change in blood and tissue tracer concentration levels, followed by scans of gradually increasing length. The number of initial short scans must be matched to the shape of the input function. In this paper, noise-free simulation studies were performed to evaluate the effect of temporal sampling on estimates of the parameters of a two-compartment kinetic model. In addition, the consequences of varying tracer infusion length and timing were studied. The kinetic model parameters' bias decreased when infusion times were lengthened or sampling rates increased. Our results indicated that tracer infusions of 30 sec were best suited for these studies. Two currently employed clinical imaging protocols were then optimized for use with this infusion scheme. Ten initial scans with durations of 10 sec, or twenty of 5 sec length produced unbiased estimates of kinetic model parameters that describe myocardial physiology. Noisy simulations with the equivalent of one million events confirmed these results.",
author = "Raylman, {R. R.} and Caraher, {J. M.} and Gary Hutchins",
year = "1993",
language = "English (US)",
volume = "34",
pages = "440--447",
journal = "Journal of Nuclear Medicine",
issn = "0161-5505",
publisher = "Society of Nuclear Medicine Inc.",
number = "3",

}

TY - JOUR

T1 - Sampling requirements for dynamic cardiac PET studies using image-derived input functions

AU - Raylman, R. R.

AU - Caraher, J. M.

AU - Hutchins, Gary

PY - 1993

Y1 - 1993

N2 - The utilization of image-derived input functions is becoming common in quantitative PET studies of the heart. Consequently, imaging protocols must be designed to sample both blood and tissue concentrations adequately. Most clinical imaging protocols consist of a series of short initial scans to measure the rapid change in blood and tissue tracer concentration levels, followed by scans of gradually increasing length. The number of initial short scans must be matched to the shape of the input function. In this paper, noise-free simulation studies were performed to evaluate the effect of temporal sampling on estimates of the parameters of a two-compartment kinetic model. In addition, the consequences of varying tracer infusion length and timing were studied. The kinetic model parameters' bias decreased when infusion times were lengthened or sampling rates increased. Our results indicated that tracer infusions of 30 sec were best suited for these studies. Two currently employed clinical imaging protocols were then optimized for use with this infusion scheme. Ten initial scans with durations of 10 sec, or twenty of 5 sec length produced unbiased estimates of kinetic model parameters that describe myocardial physiology. Noisy simulations with the equivalent of one million events confirmed these results.

AB - The utilization of image-derived input functions is becoming common in quantitative PET studies of the heart. Consequently, imaging protocols must be designed to sample both blood and tissue concentrations adequately. Most clinical imaging protocols consist of a series of short initial scans to measure the rapid change in blood and tissue tracer concentration levels, followed by scans of gradually increasing length. The number of initial short scans must be matched to the shape of the input function. In this paper, noise-free simulation studies were performed to evaluate the effect of temporal sampling on estimates of the parameters of a two-compartment kinetic model. In addition, the consequences of varying tracer infusion length and timing were studied. The kinetic model parameters' bias decreased when infusion times were lengthened or sampling rates increased. Our results indicated that tracer infusions of 30 sec were best suited for these studies. Two currently employed clinical imaging protocols were then optimized for use with this infusion scheme. Ten initial scans with durations of 10 sec, or twenty of 5 sec length produced unbiased estimates of kinetic model parameters that describe myocardial physiology. Noisy simulations with the equivalent of one million events confirmed these results.

UR - http://www.scopus.com/inward/record.url?scp=0027394099&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027394099&partnerID=8YFLogxK

M3 - Article

C2 - 8441036

AN - SCOPUS:0027394099

VL - 34

SP - 440

EP - 447

JO - Journal of Nuclear Medicine

JF - Journal of Nuclear Medicine

SN - 0161-5505

IS - 3

ER -