Shear bond strengths of brackets bonded with a new self-adhering resin composite

Ahmet Yalcin Gungor, Huseyin Alkis, Hakan Turkkahraman

Research output: Contribution to journalArticle

Abstract

Purpose: To determine the shear bond strength (SBS) of orthodontic brackets bonded with a self-adhering resin composite. Methods: 45 freshly extracted mandibular incisors were randomly divided into 3 groups (n = 15 per group). Brackets were bonded with 3 bonding systems and cured with an LED light. Brackets were bonded with a new self-adhering resin cement in the study group. A conventional etch-and-rinse adhesive system and a self-etching adhesive system were used for comparison. After bonding, the SBS of the brackets were tested with a universal testing machine. Results: Analysis of variance indicated a significant difference between groups (p<0.001). The highest values for SBS were measured in group I (21.80 ± 2.57 MPa). The SBS was significantly lower in groups II and III than in group I (P<.001). The lowest values for SBS were measured in group III (5.90 ± 0.90 MPa). SBS was significantly higher in group II than in group III (p<0.001). Conclusions: The self-adhering adhesive system showed a clinically insufficient SBS, whereas the SBS of conventional etch-and-rinse adhesive system and the self-etching adhesive system were significantly higher and clinically sufficient.

Original languageEnglish (US)
Pages (from-to)431-434
Number of pages4
JournalInternational Journal of Artificial Organs
Volume39
Issue number8
DOIs
StatePublished - Aug 1 2016
Externally publishedYes

Fingerprint

Shear Strength
Composite Resins
Adhesives
Resins
Composite materials
Etching
Resin Cements
Analysis of variance (ANOVA)
Orthodontic Brackets
Light emitting diodes
Cements
Incisor
Testing
Analysis of Variance
Light

Keywords

  • Bracket
  • Self-adhering adhesive
  • Shear bond strength

ASJC Scopus subject areas

  • Bioengineering
  • Medicine (miscellaneous)
  • Biomaterials
  • Biomedical Engineering

Cite this

Shear bond strengths of brackets bonded with a new self-adhering resin composite. / Gungor, Ahmet Yalcin; Alkis, Huseyin; Turkkahraman, Hakan.

In: International Journal of Artificial Organs, Vol. 39, No. 8, 01.08.2016, p. 431-434.

Research output: Contribution to journalArticle

@article{9dfab3aa7bde443dabe607b720baec8c,
title = "Shear bond strengths of brackets bonded with a new self-adhering resin composite",
abstract = "Purpose: To determine the shear bond strength (SBS) of orthodontic brackets bonded with a self-adhering resin composite. Methods: 45 freshly extracted mandibular incisors were randomly divided into 3 groups (n = 15 per group). Brackets were bonded with 3 bonding systems and cured with an LED light. Brackets were bonded with a new self-adhering resin cement in the study group. A conventional etch-and-rinse adhesive system and a self-etching adhesive system were used for comparison. After bonding, the SBS of the brackets were tested with a universal testing machine. Results: Analysis of variance indicated a significant difference between groups (p<0.001). The highest values for SBS were measured in group I (21.80 ± 2.57 MPa). The SBS was significantly lower in groups II and III than in group I (P<.001). The lowest values for SBS were measured in group III (5.90 ± 0.90 MPa). SBS was significantly higher in group II than in group III (p<0.001). Conclusions: The self-adhering adhesive system showed a clinically insufficient SBS, whereas the SBS of conventional etch-and-rinse adhesive system and the self-etching adhesive system were significantly higher and clinically sufficient.",
keywords = "Bracket, Self-adhering adhesive, Shear bond strength",
author = "Gungor, {Ahmet Yalcin} and Huseyin Alkis and Hakan Turkkahraman",
year = "2016",
month = "8",
day = "1",
doi = "10.5301/ijao.5000517",
language = "English (US)",
volume = "39",
pages = "431--434",
journal = "International Journal of Artificial Organs",
issn = "0391-3988",
publisher = "Wichtig Publishing",
number = "8",

}

TY - JOUR

T1 - Shear bond strengths of brackets bonded with a new self-adhering resin composite

AU - Gungor, Ahmet Yalcin

AU - Alkis, Huseyin

AU - Turkkahraman, Hakan

PY - 2016/8/1

Y1 - 2016/8/1

N2 - Purpose: To determine the shear bond strength (SBS) of orthodontic brackets bonded with a self-adhering resin composite. Methods: 45 freshly extracted mandibular incisors were randomly divided into 3 groups (n = 15 per group). Brackets were bonded with 3 bonding systems and cured with an LED light. Brackets were bonded with a new self-adhering resin cement in the study group. A conventional etch-and-rinse adhesive system and a self-etching adhesive system were used for comparison. After bonding, the SBS of the brackets were tested with a universal testing machine. Results: Analysis of variance indicated a significant difference between groups (p<0.001). The highest values for SBS were measured in group I (21.80 ± 2.57 MPa). The SBS was significantly lower in groups II and III than in group I (P<.001). The lowest values for SBS were measured in group III (5.90 ± 0.90 MPa). SBS was significantly higher in group II than in group III (p<0.001). Conclusions: The self-adhering adhesive system showed a clinically insufficient SBS, whereas the SBS of conventional etch-and-rinse adhesive system and the self-etching adhesive system were significantly higher and clinically sufficient.

AB - Purpose: To determine the shear bond strength (SBS) of orthodontic brackets bonded with a self-adhering resin composite. Methods: 45 freshly extracted mandibular incisors were randomly divided into 3 groups (n = 15 per group). Brackets were bonded with 3 bonding systems and cured with an LED light. Brackets were bonded with a new self-adhering resin cement in the study group. A conventional etch-and-rinse adhesive system and a self-etching adhesive system were used for comparison. After bonding, the SBS of the brackets were tested with a universal testing machine. Results: Analysis of variance indicated a significant difference between groups (p<0.001). The highest values for SBS were measured in group I (21.80 ± 2.57 MPa). The SBS was significantly lower in groups II and III than in group I (P<.001). The lowest values for SBS were measured in group III (5.90 ± 0.90 MPa). SBS was significantly higher in group II than in group III (p<0.001). Conclusions: The self-adhering adhesive system showed a clinically insufficient SBS, whereas the SBS of conventional etch-and-rinse adhesive system and the self-etching adhesive system were significantly higher and clinically sufficient.

KW - Bracket

KW - Self-adhering adhesive

KW - Shear bond strength

UR - http://www.scopus.com/inward/record.url?scp=84991769615&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84991769615&partnerID=8YFLogxK

U2 - 10.5301/ijao.5000517

DO - 10.5301/ijao.5000517

M3 - Article

C2 - 27646629

AN - SCOPUS:84991769615

VL - 39

SP - 431

EP - 434

JO - International Journal of Artificial Organs

JF - International Journal of Artificial Organs

SN - 0391-3988

IS - 8

ER -