Site-specific volumetric analysis of lung tumour motion

Eric W. Pepin, Huanmei Wu, George A. Sandison, Mark Langer, Hiroki Shirato

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

The treatment of lung cancer with radiation therapy is hindered by respiratory motion. Real-time adjustments to compensate for this motion are hampered by mechanical system latencies and imaging-rate restrictions. To better understand tumour motion behaviour for adaptive image-guided radiation therapy of lung cancer, the volume of a tumour's motion space was investigated. Motion data were collected by tracking an implanted fiducial using fluoroscopy at 30 Hz during treatment sessions. A total of 637 treatment fractions from 31 tumours were used in this study. For each fraction, data points collected from three consecutive breathing cycles were used to identify instantaneous tumour location. A convex hull was created over these data points, defining the tumour motion envelope. The study sought a correlation between the tumour location in the lung and the convex hull's volume and shape. It was found that tumours located in the upper apex had smaller motion envelopes (<50 mm3), whereas tumours located near the chest wall or diaphragm had larger envelopes (>70 mm3). Tumours attached to fixed anatomical structures had small motion spaces. Three general shapes described the tumour motion envelopes: 50% of motion envelopes enclosed largely 1D oscillation, 38% enclosed an ellipsoid path, 6% enclosed an arced path and 6% were of hybrid shape. This location-space correlation suggests it may be useful in developing a predictive model, but more work needs to be done to verify it.

Original languageEnglish
Pages (from-to)3325-3337
Number of pages13
JournalPhysics in Medicine and Biology
Volume55
Issue number12
DOIs
StatePublished - 2010

Fingerprint

Lung
Neoplasms
Lung Neoplasms
Image-Guided Radiotherapy
Social Adjustment
Fluoroscopy
Psychological Adaptation
Tumor Burden
Respiration
Radiotherapy
Therapeutics

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Site-specific volumetric analysis of lung tumour motion. / Pepin, Eric W.; Wu, Huanmei; Sandison, George A.; Langer, Mark; Shirato, Hiroki.

In: Physics in Medicine and Biology, Vol. 55, No. 12, 2010, p. 3325-3337.

Research output: Contribution to journalArticle

Pepin, Eric W. ; Wu, Huanmei ; Sandison, George A. ; Langer, Mark ; Shirato, Hiroki. / Site-specific volumetric analysis of lung tumour motion. In: Physics in Medicine and Biology. 2010 ; Vol. 55, No. 12. pp. 3325-3337.
@article{759ef7acea9e437297473abe8c7bf3cb,
title = "Site-specific volumetric analysis of lung tumour motion",
abstract = "The treatment of lung cancer with radiation therapy is hindered by respiratory motion. Real-time adjustments to compensate for this motion are hampered by mechanical system latencies and imaging-rate restrictions. To better understand tumour motion behaviour for adaptive image-guided radiation therapy of lung cancer, the volume of a tumour's motion space was investigated. Motion data were collected by tracking an implanted fiducial using fluoroscopy at 30 Hz during treatment sessions. A total of 637 treatment fractions from 31 tumours were used in this study. For each fraction, data points collected from three consecutive breathing cycles were used to identify instantaneous tumour location. A convex hull was created over these data points, defining the tumour motion envelope. The study sought a correlation between the tumour location in the lung and the convex hull's volume and shape. It was found that tumours located in the upper apex had smaller motion envelopes (<50 mm3), whereas tumours located near the chest wall or diaphragm had larger envelopes (>70 mm3). Tumours attached to fixed anatomical structures had small motion spaces. Three general shapes described the tumour motion envelopes: 50{\%} of motion envelopes enclosed largely 1D oscillation, 38{\%} enclosed an ellipsoid path, 6{\%} enclosed an arced path and 6{\%} were of hybrid shape. This location-space correlation suggests it may be useful in developing a predictive model, but more work needs to be done to verify it.",
author = "Pepin, {Eric W.} and Huanmei Wu and Sandison, {George A.} and Mark Langer and Hiroki Shirato",
year = "2010",
doi = "10.1088/0031-9155/55/12/005",
language = "English",
volume = "55",
pages = "3325--3337",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "12",

}

TY - JOUR

T1 - Site-specific volumetric analysis of lung tumour motion

AU - Pepin, Eric W.

AU - Wu, Huanmei

AU - Sandison, George A.

AU - Langer, Mark

AU - Shirato, Hiroki

PY - 2010

Y1 - 2010

N2 - The treatment of lung cancer with radiation therapy is hindered by respiratory motion. Real-time adjustments to compensate for this motion are hampered by mechanical system latencies and imaging-rate restrictions. To better understand tumour motion behaviour for adaptive image-guided radiation therapy of lung cancer, the volume of a tumour's motion space was investigated. Motion data were collected by tracking an implanted fiducial using fluoroscopy at 30 Hz during treatment sessions. A total of 637 treatment fractions from 31 tumours were used in this study. For each fraction, data points collected from three consecutive breathing cycles were used to identify instantaneous tumour location. A convex hull was created over these data points, defining the tumour motion envelope. The study sought a correlation between the tumour location in the lung and the convex hull's volume and shape. It was found that tumours located in the upper apex had smaller motion envelopes (<50 mm3), whereas tumours located near the chest wall or diaphragm had larger envelopes (>70 mm3). Tumours attached to fixed anatomical structures had small motion spaces. Three general shapes described the tumour motion envelopes: 50% of motion envelopes enclosed largely 1D oscillation, 38% enclosed an ellipsoid path, 6% enclosed an arced path and 6% were of hybrid shape. This location-space correlation suggests it may be useful in developing a predictive model, but more work needs to be done to verify it.

AB - The treatment of lung cancer with radiation therapy is hindered by respiratory motion. Real-time adjustments to compensate for this motion are hampered by mechanical system latencies and imaging-rate restrictions. To better understand tumour motion behaviour for adaptive image-guided radiation therapy of lung cancer, the volume of a tumour's motion space was investigated. Motion data were collected by tracking an implanted fiducial using fluoroscopy at 30 Hz during treatment sessions. A total of 637 treatment fractions from 31 tumours were used in this study. For each fraction, data points collected from three consecutive breathing cycles were used to identify instantaneous tumour location. A convex hull was created over these data points, defining the tumour motion envelope. The study sought a correlation between the tumour location in the lung and the convex hull's volume and shape. It was found that tumours located in the upper apex had smaller motion envelopes (<50 mm3), whereas tumours located near the chest wall or diaphragm had larger envelopes (>70 mm3). Tumours attached to fixed anatomical structures had small motion spaces. Three general shapes described the tumour motion envelopes: 50% of motion envelopes enclosed largely 1D oscillation, 38% enclosed an ellipsoid path, 6% enclosed an arced path and 6% were of hybrid shape. This location-space correlation suggests it may be useful in developing a predictive model, but more work needs to be done to verify it.

UR - http://www.scopus.com/inward/record.url?scp=77954166643&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77954166643&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/55/12/005

DO - 10.1088/0031-9155/55/12/005

M3 - Article

C2 - 20505220

AN - SCOPUS:77954166643

VL - 55

SP - 3325

EP - 3337

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 12

ER -