The diagnostic accuracy of bedside ocular ultrasonography for the diagnosis of retinal detachment: A systematic review and meta-analysis

Michael E. Vrablik, Gregory R. Snead, Hal Minnigan, Jonathan Kirschner, Thomas W. Emmett, Rawle A. Seupaul

Research output: Contribution to journalArticle

33 Citations (Scopus)

Abstract

The diagnostic accuracy of emergency department (ED) ocular ultrasonography may be sufficient for diagnosing retinal detachment. We systematically reviewed the literature to determine the diagnostic accuracy of ED ocular ultrasonography for the diagnosis of retinal detachment. This review conformed to the recommendations from the Meta-analysis of Observational Studies in Epidemiology statement. An experienced medical librarian searched the following databases from their inception, without language restrictions: Ovid MEDLINE, PubMed, EMBASE, the Cochrane Library, Emergency Medical Abstracts, and Google Scholar. Content experts were contacted and bibliographies of relevant studies were reviewed to identify additional references. Evidence quality was independently assessed by 2 investigators using the revised Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2). Discrepancies were resolved by consensus or adjudication by a third reviewer. Diagnostic test characteristics were summarized and reported with 95% confidence intervals. Of 7,771 unique citations identified, 78 were selected for full-text review, resulting in 4 trials assessed for quality. Agreement between authors' QUADAS-2 scoring was good (κ=0.63). Three trials were deemed to have a low risk of bias. They enrolled ED-based patients (N=201) and evaluated clinician-performed bedside ocular ultrasonography, using either a 7.5- or 10-MHz linear-array probe. Two trials included patients who had retinal detachment from trauma. The prevalence of retinal detachment ranged from 15% to 38%. Sensitivity and specificity ranged from 97% to 100% and 83% to 100%, respectively. The results of the bedside ocular ultrasonography were compared with the reference standard of an ophthalmologic evaluation; one trial also included orbital computed tomography findings suggestive of retinal detachment. Bedside ocular ultrasonography has a high degree of accuracy in identifying retinal detachment, according to 3 small prospective investigations. Larger prospective validation of these findings would be valuable.

Original languageEnglish (US)
Pages (from-to)199-203.e1
JournalAnnals of Emergency Medicine
Volume65
Issue number2
DOIs
StatePublished - Feb 1 2015

Fingerprint

Retinal Detachment
Meta-Analysis
Ultrasonography
Hospital Emergency Service
Librarians
Medical Libraries
Bibliography
Routine Diagnostic Tests
PubMed
MEDLINE
Observational Studies
Consensus
Epidemiology
Emergencies
Language
Tomography
Research Personnel
Databases
Confidence Intervals
Sensitivity and Specificity

ASJC Scopus subject areas

  • Emergency Medicine

Cite this

The diagnostic accuracy of bedside ocular ultrasonography for the diagnosis of retinal detachment : A systematic review and meta-analysis. / Vrablik, Michael E.; Snead, Gregory R.; Minnigan, Hal; Kirschner, Jonathan; Emmett, Thomas W.; Seupaul, Rawle A.

In: Annals of Emergency Medicine, Vol. 65, No. 2, 01.02.2015, p. 199-203.e1.

Research output: Contribution to journalArticle

@article{806ba6d3eb3a42a3ab0ac81982b32aee,
title = "The diagnostic accuracy of bedside ocular ultrasonography for the diagnosis of retinal detachment: A systematic review and meta-analysis",
abstract = "The diagnostic accuracy of emergency department (ED) ocular ultrasonography may be sufficient for diagnosing retinal detachment. We systematically reviewed the literature to determine the diagnostic accuracy of ED ocular ultrasonography for the diagnosis of retinal detachment. This review conformed to the recommendations from the Meta-analysis of Observational Studies in Epidemiology statement. An experienced medical librarian searched the following databases from their inception, without language restrictions: Ovid MEDLINE, PubMed, EMBASE, the Cochrane Library, Emergency Medical Abstracts, and Google Scholar. Content experts were contacted and bibliographies of relevant studies were reviewed to identify additional references. Evidence quality was independently assessed by 2 investigators using the revised Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2). Discrepancies were resolved by consensus or adjudication by a third reviewer. Diagnostic test characteristics were summarized and reported with 95{\%} confidence intervals. Of 7,771 unique citations identified, 78 were selected for full-text review, resulting in 4 trials assessed for quality. Agreement between authors' QUADAS-2 scoring was good (κ=0.63). Three trials were deemed to have a low risk of bias. They enrolled ED-based patients (N=201) and evaluated clinician-performed bedside ocular ultrasonography, using either a 7.5- or 10-MHz linear-array probe. Two trials included patients who had retinal detachment from trauma. The prevalence of retinal detachment ranged from 15{\%} to 38{\%}. Sensitivity and specificity ranged from 97{\%} to 100{\%} and 83{\%} to 100{\%}, respectively. The results of the bedside ocular ultrasonography were compared with the reference standard of an ophthalmologic evaluation; one trial also included orbital computed tomography findings suggestive of retinal detachment. Bedside ocular ultrasonography has a high degree of accuracy in identifying retinal detachment, according to 3 small prospective investigations. Larger prospective validation of these findings would be valuable.",
author = "Vrablik, {Michael E.} and Snead, {Gregory R.} and Hal Minnigan and Jonathan Kirschner and Emmett, {Thomas W.} and Seupaul, {Rawle A.}",
year = "2015",
month = "2",
day = "1",
doi = "10.1016/j.annemergmed.2014.02.020",
language = "English (US)",
volume = "65",
pages = "199--203.e1",
journal = "Annals of Emergency Medicine",
issn = "0196-0644",
publisher = "Mosby Inc.",
number = "2",

}

TY - JOUR

T1 - The diagnostic accuracy of bedside ocular ultrasonography for the diagnosis of retinal detachment

T2 - A systematic review and meta-analysis

AU - Vrablik, Michael E.

AU - Snead, Gregory R.

AU - Minnigan, Hal

AU - Kirschner, Jonathan

AU - Emmett, Thomas W.

AU - Seupaul, Rawle A.

PY - 2015/2/1

Y1 - 2015/2/1

N2 - The diagnostic accuracy of emergency department (ED) ocular ultrasonography may be sufficient for diagnosing retinal detachment. We systematically reviewed the literature to determine the diagnostic accuracy of ED ocular ultrasonography for the diagnosis of retinal detachment. This review conformed to the recommendations from the Meta-analysis of Observational Studies in Epidemiology statement. An experienced medical librarian searched the following databases from their inception, without language restrictions: Ovid MEDLINE, PubMed, EMBASE, the Cochrane Library, Emergency Medical Abstracts, and Google Scholar. Content experts were contacted and bibliographies of relevant studies were reviewed to identify additional references. Evidence quality was independently assessed by 2 investigators using the revised Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2). Discrepancies were resolved by consensus or adjudication by a third reviewer. Diagnostic test characteristics were summarized and reported with 95% confidence intervals. Of 7,771 unique citations identified, 78 were selected for full-text review, resulting in 4 trials assessed for quality. Agreement between authors' QUADAS-2 scoring was good (κ=0.63). Three trials were deemed to have a low risk of bias. They enrolled ED-based patients (N=201) and evaluated clinician-performed bedside ocular ultrasonography, using either a 7.5- or 10-MHz linear-array probe. Two trials included patients who had retinal detachment from trauma. The prevalence of retinal detachment ranged from 15% to 38%. Sensitivity and specificity ranged from 97% to 100% and 83% to 100%, respectively. The results of the bedside ocular ultrasonography were compared with the reference standard of an ophthalmologic evaluation; one trial also included orbital computed tomography findings suggestive of retinal detachment. Bedside ocular ultrasonography has a high degree of accuracy in identifying retinal detachment, according to 3 small prospective investigations. Larger prospective validation of these findings would be valuable.

AB - The diagnostic accuracy of emergency department (ED) ocular ultrasonography may be sufficient for diagnosing retinal detachment. We systematically reviewed the literature to determine the diagnostic accuracy of ED ocular ultrasonography for the diagnosis of retinal detachment. This review conformed to the recommendations from the Meta-analysis of Observational Studies in Epidemiology statement. An experienced medical librarian searched the following databases from their inception, without language restrictions: Ovid MEDLINE, PubMed, EMBASE, the Cochrane Library, Emergency Medical Abstracts, and Google Scholar. Content experts were contacted and bibliographies of relevant studies were reviewed to identify additional references. Evidence quality was independently assessed by 2 investigators using the revised Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2). Discrepancies were resolved by consensus or adjudication by a third reviewer. Diagnostic test characteristics were summarized and reported with 95% confidence intervals. Of 7,771 unique citations identified, 78 were selected for full-text review, resulting in 4 trials assessed for quality. Agreement between authors' QUADAS-2 scoring was good (κ=0.63). Three trials were deemed to have a low risk of bias. They enrolled ED-based patients (N=201) and evaluated clinician-performed bedside ocular ultrasonography, using either a 7.5- or 10-MHz linear-array probe. Two trials included patients who had retinal detachment from trauma. The prevalence of retinal detachment ranged from 15% to 38%. Sensitivity and specificity ranged from 97% to 100% and 83% to 100%, respectively. The results of the bedside ocular ultrasonography were compared with the reference standard of an ophthalmologic evaluation; one trial also included orbital computed tomography findings suggestive of retinal detachment. Bedside ocular ultrasonography has a high degree of accuracy in identifying retinal detachment, according to 3 small prospective investigations. Larger prospective validation of these findings would be valuable.

UR - http://www.scopus.com/inward/record.url?scp=84925284664&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84925284664&partnerID=8YFLogxK

U2 - 10.1016/j.annemergmed.2014.02.020

DO - 10.1016/j.annemergmed.2014.02.020

M3 - Article

C2 - 24680547

AN - SCOPUS:84925284664

VL - 65

SP - 199-203.e1

JO - Annals of Emergency Medicine

JF - Annals of Emergency Medicine

SN - 0196-0644

IS - 2

ER -