The effect of diluted penetration enhancer in nebulized mist versus liquid drop preparation forms on retrobulbar blood flow in healthy human subjects

Sally Primus, Ingrida Januleviciene, Brent Siesky, Austin Gerber, Patrick Egan, Annahita Amireskandari, Lina Siaudvytyte, Ruta Barsauskaite, Alon Harris

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

The aim of this study was to compare the effects of nebulized mist and liquid drop applications on retrobulbar blood flow. A prospective, non-randomized clinical trial was used to collect data from 40 healthy human eyes. Color Doppler Imaging determined peak systolic (PSV) and end diastolic (EDV) blood flow velocities and resistance index (RI) in the ophthalmic artery after both applications. Measurements were taken at baseline and at 1 min post-treatment in both eyes with 5 min measurements in the treatment eye only. p values ≤ 0.05 were considered statistically significant. Mist application to treatment eye produced an increase in 1 min and 5 min PSV and EDV (0.001 < p < 0.03) and a decrease in 5 min RI (p = 0.01), with no significant changes in PSV, EDV or RI of control eye or in treatment eye 1 min RI (p > 0.05). Drop application to treatment eye produced an increase in PSV (p < 0.001) and EDV (p = 0.01) at 1 min, with an increase in control eye 1 min PSV and EDV (p = 0.03). There were no statistically significant changes in treatment eye PSV, EDV and RI after 5 min (p > 0.05). The use of nebulized mist may provide an effective alternative to liquid drop medication application.

Original languageEnglish
Pages (from-to)377-384
Number of pages8
JournalPharmaceutics
Volume4
Issue number3
DOIs
StatePublished - Sep 2012

Fingerprint

Healthy Volunteers
Ophthalmic Artery
Blood Flow Velocity
Therapeutics
Color

Keywords

  • Color Doppler imaging
  • Nebulized mist
  • Retrobulbar blood flow

ASJC Scopus subject areas

  • Pharmaceutical Science

Cite this

The effect of diluted penetration enhancer in nebulized mist versus liquid drop preparation forms on retrobulbar blood flow in healthy human subjects. / Primus, Sally; Januleviciene, Ingrida; Siesky, Brent; Gerber, Austin; Egan, Patrick; Amireskandari, Annahita; Siaudvytyte, Lina; Barsauskaite, Ruta; Harris, Alon.

In: Pharmaceutics, Vol. 4, No. 3, 09.2012, p. 377-384.

Research output: Contribution to journalArticle

Primus, Sally ; Januleviciene, Ingrida ; Siesky, Brent ; Gerber, Austin ; Egan, Patrick ; Amireskandari, Annahita ; Siaudvytyte, Lina ; Barsauskaite, Ruta ; Harris, Alon. / The effect of diluted penetration enhancer in nebulized mist versus liquid drop preparation forms on retrobulbar blood flow in healthy human subjects. In: Pharmaceutics. 2012 ; Vol. 4, No. 3. pp. 377-384.
@article{d2397557fc5348b98a5f7715876e5276,
title = "The effect of diluted penetration enhancer in nebulized mist versus liquid drop preparation forms on retrobulbar blood flow in healthy human subjects",
abstract = "The aim of this study was to compare the effects of nebulized mist and liquid drop applications on retrobulbar blood flow. A prospective, non-randomized clinical trial was used to collect data from 40 healthy human eyes. Color Doppler Imaging determined peak systolic (PSV) and end diastolic (EDV) blood flow velocities and resistance index (RI) in the ophthalmic artery after both applications. Measurements were taken at baseline and at 1 min post-treatment in both eyes with 5 min measurements in the treatment eye only. p values ≤ 0.05 were considered statistically significant. Mist application to treatment eye produced an increase in 1 min and 5 min PSV and EDV (0.001 < p < 0.03) and a decrease in 5 min RI (p = 0.01), with no significant changes in PSV, EDV or RI of control eye or in treatment eye 1 min RI (p > 0.05). Drop application to treatment eye produced an increase in PSV (p < 0.001) and EDV (p = 0.01) at 1 min, with an increase in control eye 1 min PSV and EDV (p = 0.03). There were no statistically significant changes in treatment eye PSV, EDV and RI after 5 min (p > 0.05). The use of nebulized mist may provide an effective alternative to liquid drop medication application.",
keywords = "Color Doppler imaging, Nebulized mist, Retrobulbar blood flow",
author = "Sally Primus and Ingrida Januleviciene and Brent Siesky and Austin Gerber and Patrick Egan and Annahita Amireskandari and Lina Siaudvytyte and Ruta Barsauskaite and Alon Harris",
year = "2012",
month = "9",
doi = "10.3390/pharmaceutics4030377",
language = "English",
volume = "4",
pages = "377--384",
journal = "Pharmaceutics",
issn = "1999-4923",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "3",

}

TY - JOUR

T1 - The effect of diluted penetration enhancer in nebulized mist versus liquid drop preparation forms on retrobulbar blood flow in healthy human subjects

AU - Primus, Sally

AU - Januleviciene, Ingrida

AU - Siesky, Brent

AU - Gerber, Austin

AU - Egan, Patrick

AU - Amireskandari, Annahita

AU - Siaudvytyte, Lina

AU - Barsauskaite, Ruta

AU - Harris, Alon

PY - 2012/9

Y1 - 2012/9

N2 - The aim of this study was to compare the effects of nebulized mist and liquid drop applications on retrobulbar blood flow. A prospective, non-randomized clinical trial was used to collect data from 40 healthy human eyes. Color Doppler Imaging determined peak systolic (PSV) and end diastolic (EDV) blood flow velocities and resistance index (RI) in the ophthalmic artery after both applications. Measurements were taken at baseline and at 1 min post-treatment in both eyes with 5 min measurements in the treatment eye only. p values ≤ 0.05 were considered statistically significant. Mist application to treatment eye produced an increase in 1 min and 5 min PSV and EDV (0.001 < p < 0.03) and a decrease in 5 min RI (p = 0.01), with no significant changes in PSV, EDV or RI of control eye or in treatment eye 1 min RI (p > 0.05). Drop application to treatment eye produced an increase in PSV (p < 0.001) and EDV (p = 0.01) at 1 min, with an increase in control eye 1 min PSV and EDV (p = 0.03). There were no statistically significant changes in treatment eye PSV, EDV and RI after 5 min (p > 0.05). The use of nebulized mist may provide an effective alternative to liquid drop medication application.

AB - The aim of this study was to compare the effects of nebulized mist and liquid drop applications on retrobulbar blood flow. A prospective, non-randomized clinical trial was used to collect data from 40 healthy human eyes. Color Doppler Imaging determined peak systolic (PSV) and end diastolic (EDV) blood flow velocities and resistance index (RI) in the ophthalmic artery after both applications. Measurements were taken at baseline and at 1 min post-treatment in both eyes with 5 min measurements in the treatment eye only. p values ≤ 0.05 were considered statistically significant. Mist application to treatment eye produced an increase in 1 min and 5 min PSV and EDV (0.001 < p < 0.03) and a decrease in 5 min RI (p = 0.01), with no significant changes in PSV, EDV or RI of control eye or in treatment eye 1 min RI (p > 0.05). Drop application to treatment eye produced an increase in PSV (p < 0.001) and EDV (p = 0.01) at 1 min, with an increase in control eye 1 min PSV and EDV (p = 0.03). There were no statistically significant changes in treatment eye PSV, EDV and RI after 5 min (p > 0.05). The use of nebulized mist may provide an effective alternative to liquid drop medication application.

KW - Color Doppler imaging

KW - Nebulized mist

KW - Retrobulbar blood flow

UR - http://www.scopus.com/inward/record.url?scp=84865068920&partnerID=8YFLogxK