The reliability of optimization under dose-volume limits

Mark Langer, Richard Brown, Peter Kijewski, Chul Ha

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

Purpose: An optimization algorithm improves the distribution of dose among discrete points in tissues, but tolerance depends on the distribution of dose across a continuous volume. This report asks whether an exact algorithm can be completed when enough points are taken to accurately model a dose-volume constraint. Methods and Materials: Trials were performed using a 3-dimensional model of conformal therapy of lung cancer Trial were repeated with different limits placed on the fraction of lung which could receive > 20 Gy. Bounds were placed on cord dose and target dose inhomogeneity. A mixed integer algorithm was used to find a feasible set of beam weights which would maximize tumor dose. Tests of feasibility and optimality are introduced to check the solution accuracy. Results: Solutions were optimal for points used to model tissues. An accuracy of 3-4% in a volume condition could be obtained with models of 450-600 points. The error improved to 2% with 800 points to model the lung. Solution times increased six-fold at this level of accuracy. Conclusion: The mixed integer method can find optimum weights which respect dose-volume conditions in usually acceptable times. If constraints are violated by an excessive amount, the optimization model should be rerun with more points.

Original languageEnglish (US)
Pages (from-to)529-538
Number of pages10
JournalInternational Journal of Radiation Oncology Biology Physics
Volume26
Issue number3
DOIs
StatePublished - Jun 15 1993
Externally publishedYes

Fingerprint

dosage
optimization
Weights and Measures
Lung
lungs
Lung Neoplasms
integers
Neoplasms
therapy
inhomogeneity
tumors
cancer
Therapeutics

Keywords

  • Computer treatment planning
  • Dose-volume limits
  • Optimization

ASJC Scopus subject areas

  • Oncology
  • Radiology Nuclear Medicine and imaging
  • Radiation

Cite this

The reliability of optimization under dose-volume limits. / Langer, Mark; Brown, Richard; Kijewski, Peter; Ha, Chul.

In: International Journal of Radiation Oncology Biology Physics, Vol. 26, No. 3, 15.06.1993, p. 529-538.

Research output: Contribution to journalArticle

Langer, Mark ; Brown, Richard ; Kijewski, Peter ; Ha, Chul. / The reliability of optimization under dose-volume limits. In: International Journal of Radiation Oncology Biology Physics. 1993 ; Vol. 26, No. 3. pp. 529-538.
@article{1442ad31edc44260afe556ff20dc0c43,
title = "The reliability of optimization under dose-volume limits",
abstract = "Purpose: An optimization algorithm improves the distribution of dose among discrete points in tissues, but tolerance depends on the distribution of dose across a continuous volume. This report asks whether an exact algorithm can be completed when enough points are taken to accurately model a dose-volume constraint. Methods and Materials: Trials were performed using a 3-dimensional model of conformal therapy of lung cancer Trial were repeated with different limits placed on the fraction of lung which could receive > 20 Gy. Bounds were placed on cord dose and target dose inhomogeneity. A mixed integer algorithm was used to find a feasible set of beam weights which would maximize tumor dose. Tests of feasibility and optimality are introduced to check the solution accuracy. Results: Solutions were optimal for points used to model tissues. An accuracy of 3-4{\%} in a volume condition could be obtained with models of 450-600 points. The error improved to 2{\%} with 800 points to model the lung. Solution times increased six-fold at this level of accuracy. Conclusion: The mixed integer method can find optimum weights which respect dose-volume conditions in usually acceptable times. If constraints are violated by an excessive amount, the optimization model should be rerun with more points.",
keywords = "Computer treatment planning, Dose-volume limits, Optimization",
author = "Mark Langer and Richard Brown and Peter Kijewski and Chul Ha",
year = "1993",
month = "6",
day = "15",
doi = "10.1016/0360-3016(93)90972-X",
language = "English (US)",
volume = "26",
pages = "529--538",
journal = "International Journal of Radiation Oncology Biology Physics",
issn = "0360-3016",
publisher = "Elsevier Inc.",
number = "3",

}

TY - JOUR

T1 - The reliability of optimization under dose-volume limits

AU - Langer, Mark

AU - Brown, Richard

AU - Kijewski, Peter

AU - Ha, Chul

PY - 1993/6/15

Y1 - 1993/6/15

N2 - Purpose: An optimization algorithm improves the distribution of dose among discrete points in tissues, but tolerance depends on the distribution of dose across a continuous volume. This report asks whether an exact algorithm can be completed when enough points are taken to accurately model a dose-volume constraint. Methods and Materials: Trials were performed using a 3-dimensional model of conformal therapy of lung cancer Trial were repeated with different limits placed on the fraction of lung which could receive > 20 Gy. Bounds were placed on cord dose and target dose inhomogeneity. A mixed integer algorithm was used to find a feasible set of beam weights which would maximize tumor dose. Tests of feasibility and optimality are introduced to check the solution accuracy. Results: Solutions were optimal for points used to model tissues. An accuracy of 3-4% in a volume condition could be obtained with models of 450-600 points. The error improved to 2% with 800 points to model the lung. Solution times increased six-fold at this level of accuracy. Conclusion: The mixed integer method can find optimum weights which respect dose-volume conditions in usually acceptable times. If constraints are violated by an excessive amount, the optimization model should be rerun with more points.

AB - Purpose: An optimization algorithm improves the distribution of dose among discrete points in tissues, but tolerance depends on the distribution of dose across a continuous volume. This report asks whether an exact algorithm can be completed when enough points are taken to accurately model a dose-volume constraint. Methods and Materials: Trials were performed using a 3-dimensional model of conformal therapy of lung cancer Trial were repeated with different limits placed on the fraction of lung which could receive > 20 Gy. Bounds were placed on cord dose and target dose inhomogeneity. A mixed integer algorithm was used to find a feasible set of beam weights which would maximize tumor dose. Tests of feasibility and optimality are introduced to check the solution accuracy. Results: Solutions were optimal for points used to model tissues. An accuracy of 3-4% in a volume condition could be obtained with models of 450-600 points. The error improved to 2% with 800 points to model the lung. Solution times increased six-fold at this level of accuracy. Conclusion: The mixed integer method can find optimum weights which respect dose-volume conditions in usually acceptable times. If constraints are violated by an excessive amount, the optimization model should be rerun with more points.

KW - Computer treatment planning

KW - Dose-volume limits

KW - Optimization

UR - http://www.scopus.com/inward/record.url?scp=0027311275&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0027311275&partnerID=8YFLogxK

U2 - 10.1016/0360-3016(93)90972-X

DO - 10.1016/0360-3016(93)90972-X

M3 - Article

VL - 26

SP - 529

EP - 538

JO - International Journal of Radiation Oncology Biology Physics

JF - International Journal of Radiation Oncology Biology Physics

SN - 0360-3016

IS - 3

ER -