The Validity and Repeatability of Three Light-Induced Fluorescence Systems

An in vitro Study

M. D. Lagerweij, M. H. Van Der Veen, Masatoshi Ando, L. Lukantsova, G. K. Stookey

Research output: Contribution to journalArticle

50 Citations (Scopus)

Abstract

New optical systems are being developed that aim to determine the extent of demineralization in enamel. In our laboratory we have compared three such systems: a ring illuminator equipped with a laser, a beam splitter also equipped with a laser and an intra-oral camera equipped with a white-light arc lamp. The aim of the study was to compare the ability of the different optical systems to detect small enamel lesions with microradiographic analysis and to determine the repeatability of these systems. Forty human enamel specimens (3mm in diameter) were mounted in acrylic and polished. The specimens were kept moist throughout the study. Each specimen of the four groups was individually exposed to 14 ml of Carbopol demineralizing solution for 24, 48, 72 and 96 h, respectively. The mineral loss of the 40 specimens was assessed with blue-violet light-induced fluorescence. Each image was captured with a video camera and analysed with dedicated software. The measurements were repeated 3 times with complete shut-down of the system in between the measurements. The same measurements were performed with the ring illuminator, the beam splitter and the arc lamp. The specimens were then cut into thin sections and analysed with microradiography. Similar high correlations between microradiography and the light-based analysis systems were found for the beam splitter and the clinical caries camera set-up. The repeatability was best for the beam splitter set-up. This indicates that the light-induced fluorescence measurement technique can be used in different configurations and that the repeatability of the measurements is influenced by the physical stability of the set-up.

Original languageEnglish (US)
Pages (from-to)220-226
Number of pages7
JournalCaries Research
Volume33
Issue number3
DOIs
StatePublished - May 1999

Fingerprint

Dental Enamel
Fluorescence
Microradiography
Light
Optical Devices
Lasers
Viola
Minerals
Software
In Vitro Techniques

Keywords

  • Caries
  • Demineralization
  • Optics
  • Quantification, in vitro

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

The Validity and Repeatability of Three Light-Induced Fluorescence Systems : An in vitro Study. / Lagerweij, M. D.; Van Der Veen, M. H.; Ando, Masatoshi; Lukantsova, L.; Stookey, G. K.

In: Caries Research, Vol. 33, No. 3, 05.1999, p. 220-226.

Research output: Contribution to journalArticle

Lagerweij, MD, Van Der Veen, MH, Ando, M, Lukantsova, L & Stookey, GK 1999, 'The Validity and Repeatability of Three Light-Induced Fluorescence Systems: An in vitro Study', Caries Research, vol. 33, no. 3, pp. 220-226. https://doi.org/10.1159/000016520
Lagerweij, M. D. ; Van Der Veen, M. H. ; Ando, Masatoshi ; Lukantsova, L. ; Stookey, G. K. / The Validity and Repeatability of Three Light-Induced Fluorescence Systems : An in vitro Study. In: Caries Research. 1999 ; Vol. 33, No. 3. pp. 220-226.
@article{db385623cbee4b2c84ef9e79bc404324,
title = "The Validity and Repeatability of Three Light-Induced Fluorescence Systems: An in vitro Study",
abstract = "New optical systems are being developed that aim to determine the extent of demineralization in enamel. In our laboratory we have compared three such systems: a ring illuminator equipped with a laser, a beam splitter also equipped with a laser and an intra-oral camera equipped with a white-light arc lamp. The aim of the study was to compare the ability of the different optical systems to detect small enamel lesions with microradiographic analysis and to determine the repeatability of these systems. Forty human enamel specimens (3mm in diameter) were mounted in acrylic and polished. The specimens were kept moist throughout the study. Each specimen of the four groups was individually exposed to 14 ml of Carbopol demineralizing solution for 24, 48, 72 and 96 h, respectively. The mineral loss of the 40 specimens was assessed with blue-violet light-induced fluorescence. Each image was captured with a video camera and analysed with dedicated software. The measurements were repeated 3 times with complete shut-down of the system in between the measurements. The same measurements were performed with the ring illuminator, the beam splitter and the arc lamp. The specimens were then cut into thin sections and analysed with microradiography. Similar high correlations between microradiography and the light-based analysis systems were found for the beam splitter and the clinical caries camera set-up. The repeatability was best for the beam splitter set-up. This indicates that the light-induced fluorescence measurement technique can be used in different configurations and that the repeatability of the measurements is influenced by the physical stability of the set-up.",
keywords = "Caries, Demineralization, Optics, Quantification, in vitro",
author = "Lagerweij, {M. D.} and {Van Der Veen}, {M. H.} and Masatoshi Ando and L. Lukantsova and Stookey, {G. K.}",
year = "1999",
month = "5",
doi = "10.1159/000016520",
language = "English (US)",
volume = "33",
pages = "220--226",
journal = "Caries Research",
issn = "0008-6568",
publisher = "S. Karger AG",
number = "3",

}

TY - JOUR

T1 - The Validity and Repeatability of Three Light-Induced Fluorescence Systems

T2 - An in vitro Study

AU - Lagerweij, M. D.

AU - Van Der Veen, M. H.

AU - Ando, Masatoshi

AU - Lukantsova, L.

AU - Stookey, G. K.

PY - 1999/5

Y1 - 1999/5

N2 - New optical systems are being developed that aim to determine the extent of demineralization in enamel. In our laboratory we have compared three such systems: a ring illuminator equipped with a laser, a beam splitter also equipped with a laser and an intra-oral camera equipped with a white-light arc lamp. The aim of the study was to compare the ability of the different optical systems to detect small enamel lesions with microradiographic analysis and to determine the repeatability of these systems. Forty human enamel specimens (3mm in diameter) were mounted in acrylic and polished. The specimens were kept moist throughout the study. Each specimen of the four groups was individually exposed to 14 ml of Carbopol demineralizing solution for 24, 48, 72 and 96 h, respectively. The mineral loss of the 40 specimens was assessed with blue-violet light-induced fluorescence. Each image was captured with a video camera and analysed with dedicated software. The measurements were repeated 3 times with complete shut-down of the system in between the measurements. The same measurements were performed with the ring illuminator, the beam splitter and the arc lamp. The specimens were then cut into thin sections and analysed with microradiography. Similar high correlations between microradiography and the light-based analysis systems were found for the beam splitter and the clinical caries camera set-up. The repeatability was best for the beam splitter set-up. This indicates that the light-induced fluorescence measurement technique can be used in different configurations and that the repeatability of the measurements is influenced by the physical stability of the set-up.

AB - New optical systems are being developed that aim to determine the extent of demineralization in enamel. In our laboratory we have compared three such systems: a ring illuminator equipped with a laser, a beam splitter also equipped with a laser and an intra-oral camera equipped with a white-light arc lamp. The aim of the study was to compare the ability of the different optical systems to detect small enamel lesions with microradiographic analysis and to determine the repeatability of these systems. Forty human enamel specimens (3mm in diameter) were mounted in acrylic and polished. The specimens were kept moist throughout the study. Each specimen of the four groups was individually exposed to 14 ml of Carbopol demineralizing solution for 24, 48, 72 and 96 h, respectively. The mineral loss of the 40 specimens was assessed with blue-violet light-induced fluorescence. Each image was captured with a video camera and analysed with dedicated software. The measurements were repeated 3 times with complete shut-down of the system in between the measurements. The same measurements were performed with the ring illuminator, the beam splitter and the arc lamp. The specimens were then cut into thin sections and analysed with microradiography. Similar high correlations between microradiography and the light-based analysis systems were found for the beam splitter and the clinical caries camera set-up. The repeatability was best for the beam splitter set-up. This indicates that the light-induced fluorescence measurement technique can be used in different configurations and that the repeatability of the measurements is influenced by the physical stability of the set-up.

KW - Caries

KW - Demineralization

KW - Optics

KW - Quantification, in vitro

UR - http://www.scopus.com/inward/record.url?scp=0033125532&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033125532&partnerID=8YFLogxK

U2 - 10.1159/000016520

DO - 10.1159/000016520

M3 - Article

VL - 33

SP - 220

EP - 226

JO - Caries Research

JF - Caries Research

SN - 0008-6568

IS - 3

ER -