Three-dimensional conformal radiation therapy in the liver: MRI findings along a time continuum

Chandana Lall, Puneet Bhargava, Kumar Sandrasegaran, Alampady K. Shanbhogue, Nilam Ramsinghani, Young Whan Koh, Jin Young Choi, Joon Il Choi

Research output: Contribution to journalArticle

5 Citations (Scopus)

Abstract

Recent development of 3-dimensional conformal radiation therapies provides a concentrated radiation dose to the tumor. To achieve this goal, a complex design of multiple narrow beamlets is used to shape the radiation exposure to conform to the shape of the tumor. Imaging findings after novel radiation therapy techniques differ from those of conventional radiation therapy. This article discusses changes in the liver parenchyma and tumor after conformal radiation therapy focusing on magnetic resonance imaging.

Original languageEnglish (US)
Pages (from-to)356-364
Number of pages9
JournalJournal of Computer Assisted Tomography
Volume39
Issue number3
DOIs
StatePublished - May 29 2015

Fingerprint

Radiotherapy
Liver
Neoplasms
Magnetic Resonance Imaging
Radiation

Keywords

  • liver
  • magnetic resonance imaging
  • radiation injury
  • radiation therapy

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Three-dimensional conformal radiation therapy in the liver : MRI findings along a time continuum. / Lall, Chandana; Bhargava, Puneet; Sandrasegaran, Kumar; Shanbhogue, Alampady K.; Ramsinghani, Nilam; Koh, Young Whan; Choi, Jin Young; Choi, Joon Il.

In: Journal of Computer Assisted Tomography, Vol. 39, No. 3, 29.05.2015, p. 356-364.

Research output: Contribution to journalArticle

Lall, Chandana ; Bhargava, Puneet ; Sandrasegaran, Kumar ; Shanbhogue, Alampady K. ; Ramsinghani, Nilam ; Koh, Young Whan ; Choi, Jin Young ; Choi, Joon Il. / Three-dimensional conformal radiation therapy in the liver : MRI findings along a time continuum. In: Journal of Computer Assisted Tomography. 2015 ; Vol. 39, No. 3. pp. 356-364.
@article{a9b656c0ddc04d9b81c54c64260187c4,
title = "Three-dimensional conformal radiation therapy in the liver: MRI findings along a time continuum",
abstract = "Recent development of 3-dimensional conformal radiation therapies provides a concentrated radiation dose to the tumor. To achieve this goal, a complex design of multiple narrow beamlets is used to shape the radiation exposure to conform to the shape of the tumor. Imaging findings after novel radiation therapy techniques differ from those of conventional radiation therapy. This article discusses changes in the liver parenchyma and tumor after conformal radiation therapy focusing on magnetic resonance imaging.",
keywords = "liver, magnetic resonance imaging, radiation injury, radiation therapy",
author = "Chandana Lall and Puneet Bhargava and Kumar Sandrasegaran and Shanbhogue, {Alampady K.} and Nilam Ramsinghani and Koh, {Young Whan} and Choi, {Jin Young} and Choi, {Joon Il}",
year = "2015",
month = "5",
day = "29",
doi = "10.1097/RCT.0000000000000219",
language = "English (US)",
volume = "39",
pages = "356--364",
journal = "Journal of Computer Assisted Tomography",
issn = "0363-8715",
publisher = "Lippincott Williams and Wilkins",
number = "3",

}

TY - JOUR

T1 - Three-dimensional conformal radiation therapy in the liver

T2 - MRI findings along a time continuum

AU - Lall, Chandana

AU - Bhargava, Puneet

AU - Sandrasegaran, Kumar

AU - Shanbhogue, Alampady K.

AU - Ramsinghani, Nilam

AU - Koh, Young Whan

AU - Choi, Jin Young

AU - Choi, Joon Il

PY - 2015/5/29

Y1 - 2015/5/29

N2 - Recent development of 3-dimensional conformal radiation therapies provides a concentrated radiation dose to the tumor. To achieve this goal, a complex design of multiple narrow beamlets is used to shape the radiation exposure to conform to the shape of the tumor. Imaging findings after novel radiation therapy techniques differ from those of conventional radiation therapy. This article discusses changes in the liver parenchyma and tumor after conformal radiation therapy focusing on magnetic resonance imaging.

AB - Recent development of 3-dimensional conformal radiation therapies provides a concentrated radiation dose to the tumor. To achieve this goal, a complex design of multiple narrow beamlets is used to shape the radiation exposure to conform to the shape of the tumor. Imaging findings after novel radiation therapy techniques differ from those of conventional radiation therapy. This article discusses changes in the liver parenchyma and tumor after conformal radiation therapy focusing on magnetic resonance imaging.

KW - liver

KW - magnetic resonance imaging

KW - radiation injury

KW - radiation therapy

UR - http://www.scopus.com/inward/record.url?scp=84930061291&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84930061291&partnerID=8YFLogxK

U2 - 10.1097/RCT.0000000000000219

DO - 10.1097/RCT.0000000000000219

M3 - Article

C2 - 25700224

AN - SCOPUS:84930061291

VL - 39

SP - 356

EP - 364

JO - Journal of Computer Assisted Tomography

JF - Journal of Computer Assisted Tomography

SN - 0363-8715

IS - 3

ER -