Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE®/ optical-CT 3D dosimetry system

Corey Clift, Andrew Thomas, John Adamovics, Zheng Chang, Indra Das, Mark Oldham

Research output: Contribution to journalArticle

44 Citations (Scopus)

Abstract

Achieving accurate small field dosimetry is challenging. This study investigates the utility of a radiochromic plastic PRESAGE® read with optical-CT for the acquisition of radiosurgery field commissioning data from a Novalis Tx system with a high-definition multileaf collimator (HDMLC). Total scatter factors (Sc, p), beam profiles, and penumbrae were measured for five different radiosurgery fields (5, 10, 20, 30 and 40 mm) using a commercially available optical-CT scanner (OCTOPUS, MGS Research). The percent depth dose (PDD), beam profile and penumbra of the 10 mm field were also measured using a higher resolution in-house prototype CCD-based scanner. Gafchromic EBT® film was used for independent verification. Measurements of Sc, p made with PRESAGE® and film agreed with mini-ion chamber commissioning data to within 4% for every field (range 0.2-3.6% for PRESAGE®, and 1.6-3.6% for EBT). PDD, beam profile and penumbra measurements made with the two PRESAGE®/ optical-CT systems and film showed good agreement with the high-resolution diode commissioning measurements with a competitive resolution (0.5 mm pixels). The in-house prototype optical-CT scanner allowed much finer resolution compared with previous applications of PRESAGE®. The advantages of the PRESAGE® system for small field dosimetry include 3D measurements, negligible volume averaging, directional insensitivity, an absence of beam perturbations, energy and dose rate independence.

Original languageEnglish
Pages (from-to)1279-1293
Number of pages15
JournalPhysics in Medicine and Biology
Volume55
Issue number5
DOIs
StatePublished - 2010

Fingerprint

Radiosurgery
Optical Devices
Hepatocyte Growth Factor
Plastics
Ions
Research

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE®/ optical-CT 3D dosimetry system. / Clift, Corey; Thomas, Andrew; Adamovics, John; Chang, Zheng; Das, Indra; Oldham, Mark.

In: Physics in Medicine and Biology, Vol. 55, No. 5, 2010, p. 1279-1293.

Research output: Contribution to journalArticle

Clift, Corey ; Thomas, Andrew ; Adamovics, John ; Chang, Zheng ; Das, Indra ; Oldham, Mark. / Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE®/ optical-CT 3D dosimetry system. In: Physics in Medicine and Biology. 2010 ; Vol. 55, No. 5. pp. 1279-1293.
@article{280c9a50d155415bbc60e76096cfddad,
title = "Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE{\circledR}/ optical-CT 3D dosimetry system",
abstract = "Achieving accurate small field dosimetry is challenging. This study investigates the utility of a radiochromic plastic PRESAGE{\circledR} read with optical-CT for the acquisition of radiosurgery field commissioning data from a Novalis Tx system with a high-definition multileaf collimator (HDMLC). Total scatter factors (Sc, p), beam profiles, and penumbrae were measured for five different radiosurgery fields (5, 10, 20, 30 and 40 mm) using a commercially available optical-CT scanner (OCTOPUS, MGS Research). The percent depth dose (PDD), beam profile and penumbra of the 10 mm field were also measured using a higher resolution in-house prototype CCD-based scanner. Gafchromic EBT{\circledR} film was used for independent verification. Measurements of Sc, p made with PRESAGE{\circledR} and film agreed with mini-ion chamber commissioning data to within 4{\%} for every field (range 0.2-3.6{\%} for PRESAGE{\circledR}, and 1.6-3.6{\%} for EBT). PDD, beam profile and penumbra measurements made with the two PRESAGE{\circledR}/ optical-CT systems and film showed good agreement with the high-resolution diode commissioning measurements with a competitive resolution (0.5 mm pixels). The in-house prototype optical-CT scanner allowed much finer resolution compared with previous applications of PRESAGE{\circledR}. The advantages of the PRESAGE{\circledR} system for small field dosimetry include 3D measurements, negligible volume averaging, directional insensitivity, an absence of beam perturbations, energy and dose rate independence.",
author = "Corey Clift and Andrew Thomas and John Adamovics and Zheng Chang and Indra Das and Mark Oldham",
year = "2010",
doi = "10.1088/0031-9155/55/5/002",
language = "English",
volume = "55",
pages = "1279--1293",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "5",

}

TY - JOUR

T1 - Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE®/ optical-CT 3D dosimetry system

AU - Clift, Corey

AU - Thomas, Andrew

AU - Adamovics, John

AU - Chang, Zheng

AU - Das, Indra

AU - Oldham, Mark

PY - 2010

Y1 - 2010

N2 - Achieving accurate small field dosimetry is challenging. This study investigates the utility of a radiochromic plastic PRESAGE® read with optical-CT for the acquisition of radiosurgery field commissioning data from a Novalis Tx system with a high-definition multileaf collimator (HDMLC). Total scatter factors (Sc, p), beam profiles, and penumbrae were measured for five different radiosurgery fields (5, 10, 20, 30 and 40 mm) using a commercially available optical-CT scanner (OCTOPUS, MGS Research). The percent depth dose (PDD), beam profile and penumbra of the 10 mm field were also measured using a higher resolution in-house prototype CCD-based scanner. Gafchromic EBT® film was used for independent verification. Measurements of Sc, p made with PRESAGE® and film agreed with mini-ion chamber commissioning data to within 4% for every field (range 0.2-3.6% for PRESAGE®, and 1.6-3.6% for EBT). PDD, beam profile and penumbra measurements made with the two PRESAGE®/ optical-CT systems and film showed good agreement with the high-resolution diode commissioning measurements with a competitive resolution (0.5 mm pixels). The in-house prototype optical-CT scanner allowed much finer resolution compared with previous applications of PRESAGE®. The advantages of the PRESAGE® system for small field dosimetry include 3D measurements, negligible volume averaging, directional insensitivity, an absence of beam perturbations, energy and dose rate independence.

AB - Achieving accurate small field dosimetry is challenging. This study investigates the utility of a radiochromic plastic PRESAGE® read with optical-CT for the acquisition of radiosurgery field commissioning data from a Novalis Tx system with a high-definition multileaf collimator (HDMLC). Total scatter factors (Sc, p), beam profiles, and penumbrae were measured for five different radiosurgery fields (5, 10, 20, 30 and 40 mm) using a commercially available optical-CT scanner (OCTOPUS, MGS Research). The percent depth dose (PDD), beam profile and penumbra of the 10 mm field were also measured using a higher resolution in-house prototype CCD-based scanner. Gafchromic EBT® film was used for independent verification. Measurements of Sc, p made with PRESAGE® and film agreed with mini-ion chamber commissioning data to within 4% for every field (range 0.2-3.6% for PRESAGE®, and 1.6-3.6% for EBT). PDD, beam profile and penumbra measurements made with the two PRESAGE®/ optical-CT systems and film showed good agreement with the high-resolution diode commissioning measurements with a competitive resolution (0.5 mm pixels). The in-house prototype optical-CT scanner allowed much finer resolution compared with previous applications of PRESAGE®. The advantages of the PRESAGE® system for small field dosimetry include 3D measurements, negligible volume averaging, directional insensitivity, an absence of beam perturbations, energy and dose rate independence.

UR - http://www.scopus.com/inward/record.url?scp=76849096681&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=76849096681&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/55/5/002

DO - 10.1088/0031-9155/55/5/002

M3 - Article

C2 - 20134082

AN - SCOPUS:76849096681

VL - 55

SP - 1279

EP - 1293

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 5

ER -