Transthoracic echocardiographic power motion tissue imaging of an intracardiac tumor that could not be seen with conventional transthoracic echocardiographic recordings

Jr Maxted W.C., D. S. Segar, Stephen Sawada, T. X. Aufiero, Harvey Feigenbaum

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Power motion imaging allows interrogation of low-velocity tissue. By means of power motion imaging with 2 different late-model echographs we identified an intra-atrial tumor that was undetectable on conventional transthoracic echocardiograms.

Original languageEnglish
Pages (from-to)989-991
Number of pages3
JournalJournal of the American Society of Echocardiography
Volume11
Issue number10
DOIs
StatePublished - 1998

Fingerprint

Neoplasms

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Cite this

@article{57f52c2b296a4900a7095cbb34e0a6c5,
title = "Transthoracic echocardiographic power motion tissue imaging of an intracardiac tumor that could not be seen with conventional transthoracic echocardiographic recordings",
abstract = "Power motion imaging allows interrogation of low-velocity tissue. By means of power motion imaging with 2 different late-model echographs we identified an intra-atrial tumor that was undetectable on conventional transthoracic echocardiograms.",
author = "{Maxted W.C.}, Jr and Segar, {D. S.} and Stephen Sawada and Aufiero, {T. X.} and Harvey Feigenbaum",
year = "1998",
doi = "10.1016/S0894-7317(98)70144-0",
language = "English",
volume = "11",
pages = "989--991",
journal = "Journal of the American Society of Echocardiography",
issn = "0894-7317",
publisher = "Mosby Inc.",
number = "10",

}

TY - JOUR

T1 - Transthoracic echocardiographic power motion tissue imaging of an intracardiac tumor that could not be seen with conventional transthoracic echocardiographic recordings

AU - Maxted W.C., Jr

AU - Segar, D. S.

AU - Sawada, Stephen

AU - Aufiero, T. X.

AU - Feigenbaum, Harvey

PY - 1998

Y1 - 1998

N2 - Power motion imaging allows interrogation of low-velocity tissue. By means of power motion imaging with 2 different late-model echographs we identified an intra-atrial tumor that was undetectable on conventional transthoracic echocardiograms.

AB - Power motion imaging allows interrogation of low-velocity tissue. By means of power motion imaging with 2 different late-model echographs we identified an intra-atrial tumor that was undetectable on conventional transthoracic echocardiograms.

UR - http://www.scopus.com/inward/record.url?scp=0031791761&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031791761&partnerID=8YFLogxK

U2 - 10.1016/S0894-7317(98)70144-0

DO - 10.1016/S0894-7317(98)70144-0

M3 - Article

C2 - 9804107

AN - SCOPUS:0031791761

VL - 11

SP - 989

EP - 991

JO - Journal of the American Society of Echocardiography

JF - Journal of the American Society of Echocardiography

SN - 0894-7317

IS - 10

ER -