Using posturography to measure balance control during seated tai chi

Roy W. Geib, Hongtao Li, Gabi N. Waite, Guido Pagnacco, Elena Oggero, Beverly L. Roberts

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Background: Tai Chi for Arthritis (TCA) is recognized by the CDC as an evidenced-based program to prevent falls in older adults. Although seated Tai Chi is recommended for those unable to stand, little is known about balance control during seated TCA. Purpose: To explore the use of posturography to assess differences between experts and non-expert practitioners of seated TCA. Methods: Twenty-three participants were recruited from those attending a Tai cChi workshop. While seated in a hard back chair centered on a force platform, participants performed selected forms from TCA and then did them in a continuous sequence. Center of pressure (CoP) indices to assess balance were normalized by height and then compared between expert and non-expert participants. Results: Experts had significantly greater average velocity and path length (p ≤ 0.02) for the entire sequence and open/ close, but not for CoP 95% Confidence ellipse area. No significant differences in the CoP were found for commencement, wave hands, or single whip. Conclusions: A few differences in balance control while performing seated TCA movements were found. Future studies are needed to determine whether these can be accounted for by quality of the Tai Chi movements or factors associated with the seated position.

Original languageEnglish
Title of host publication51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014
PublisherISA - Instrumentation, Systems, and Automation Society
Pages235-241
Number of pages7
ISBN (Print)9781632663917
StatePublished - 2014
Event51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014 - Denver, CO, United States
Duration: Apr 4 2014Apr 6 2014

Other

Other51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014
CountryUnited States
CityDenver, CO
Period4/4/144/6/14

Fingerprint

arthritis
center of pressure
ellipses
seats
confidence
platforms

Keywords

  • Exercise
  • Posturography
  • Tai chi

ASJC Scopus subject areas

  • Bioengineering
  • Biomedical Engineering
  • Instrumentation

Cite this

Geib, R. W., Li, H., Waite, G. N., Pagnacco, G., Oggero, E., & Roberts, B. L. (2014). Using posturography to measure balance control during seated tai chi. In 51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014 (pp. 235-241). ISA - Instrumentation, Systems, and Automation Society.

Using posturography to measure balance control during seated tai chi. / Geib, Roy W.; Li, Hongtao; Waite, Gabi N.; Pagnacco, Guido; Oggero, Elena; Roberts, Beverly L.

51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014. ISA - Instrumentation, Systems, and Automation Society, 2014. p. 235-241.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Geib, RW, Li, H, Waite, GN, Pagnacco, G, Oggero, E & Roberts, BL 2014, Using posturography to measure balance control during seated tai chi. in 51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014. ISA - Instrumentation, Systems, and Automation Society, pp. 235-241, 51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014, Denver, CO, United States, 4/4/14.
Geib RW, Li H, Waite GN, Pagnacco G, Oggero E, Roberts BL. Using posturography to measure balance control during seated tai chi. In 51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014. ISA - Instrumentation, Systems, and Automation Society. 2014. p. 235-241
Geib, Roy W. ; Li, Hongtao ; Waite, Gabi N. ; Pagnacco, Guido ; Oggero, Elena ; Roberts, Beverly L. / Using posturography to measure balance control during seated tai chi. 51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014. ISA - Instrumentation, Systems, and Automation Society, 2014. pp. 235-241
@inproceedings{3367ebcd314a4e6ab783d47b7a504267,
title = "Using posturography to measure balance control during seated tai chi",
abstract = "Background: Tai Chi for Arthritis (TCA) is recognized by the CDC as an evidenced-based program to prevent falls in older adults. Although seated Tai Chi is recommended for those unable to stand, little is known about balance control during seated TCA. Purpose: To explore the use of posturography to assess differences between experts and non-expert practitioners of seated TCA. Methods: Twenty-three participants were recruited from those attending a Tai cChi workshop. While seated in a hard back chair centered on a force platform, participants performed selected forms from TCA and then did them in a continuous sequence. Center of pressure (CoP) indices to assess balance were normalized by height and then compared between expert and non-expert participants. Results: Experts had significantly greater average velocity and path length (p ≤ 0.02) for the entire sequence and open/ close, but not for CoP 95{\%} Confidence ellipse area. No significant differences in the CoP were found for commencement, wave hands, or single whip. Conclusions: A few differences in balance control while performing seated TCA movements were found. Future studies are needed to determine whether these can be accounted for by quality of the Tai Chi movements or factors associated with the seated position.",
keywords = "Exercise, Posturography, Tai chi",
author = "Geib, {Roy W.} and Hongtao Li and Waite, {Gabi N.} and Guido Pagnacco and Elena Oggero and Roberts, {Beverly L.}",
year = "2014",
language = "English",
isbn = "9781632663917",
pages = "235--241",
booktitle = "51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014",
publisher = "ISA - Instrumentation, Systems, and Automation Society",

}

TY - GEN

T1 - Using posturography to measure balance control during seated tai chi

AU - Geib, Roy W.

AU - Li, Hongtao

AU - Waite, Gabi N.

AU - Pagnacco, Guido

AU - Oggero, Elena

AU - Roberts, Beverly L.

PY - 2014

Y1 - 2014

N2 - Background: Tai Chi for Arthritis (TCA) is recognized by the CDC as an evidenced-based program to prevent falls in older adults. Although seated Tai Chi is recommended for those unable to stand, little is known about balance control during seated TCA. Purpose: To explore the use of posturography to assess differences between experts and non-expert practitioners of seated TCA. Methods: Twenty-three participants were recruited from those attending a Tai cChi workshop. While seated in a hard back chair centered on a force platform, participants performed selected forms from TCA and then did them in a continuous sequence. Center of pressure (CoP) indices to assess balance were normalized by height and then compared between expert and non-expert participants. Results: Experts had significantly greater average velocity and path length (p ≤ 0.02) for the entire sequence and open/ close, but not for CoP 95% Confidence ellipse area. No significant differences in the CoP were found for commencement, wave hands, or single whip. Conclusions: A few differences in balance control while performing seated TCA movements were found. Future studies are needed to determine whether these can be accounted for by quality of the Tai Chi movements or factors associated with the seated position.

AB - Background: Tai Chi for Arthritis (TCA) is recognized by the CDC as an evidenced-based program to prevent falls in older adults. Although seated Tai Chi is recommended for those unable to stand, little is known about balance control during seated TCA. Purpose: To explore the use of posturography to assess differences between experts and non-expert practitioners of seated TCA. Methods: Twenty-three participants were recruited from those attending a Tai cChi workshop. While seated in a hard back chair centered on a force platform, participants performed selected forms from TCA and then did them in a continuous sequence. Center of pressure (CoP) indices to assess balance were normalized by height and then compared between expert and non-expert participants. Results: Experts had significantly greater average velocity and path length (p ≤ 0.02) for the entire sequence and open/ close, but not for CoP 95% Confidence ellipse area. No significant differences in the CoP were found for commencement, wave hands, or single whip. Conclusions: A few differences in balance control while performing seated TCA movements were found. Future studies are needed to determine whether these can be accounted for by quality of the Tai Chi movements or factors associated with the seated position.

KW - Exercise

KW - Posturography

KW - Tai chi

UR - http://www.scopus.com/inward/record.url?scp=84904881529&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84904881529&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84904881529

SN - 9781632663917

SP - 235

EP - 241

BT - 51st Annual Rocky Mountain Bioengineering Symposium, RMBS 2014 and 51st International ISA Biomedical Sciences Instrumentation Symposium 2014

PB - ISA - Instrumentation, Systems, and Automation Society

ER -