Objective: Use of the VersaStep™ trocar system (US Surgical, Norwalk, CT) has the perceived advantage of minimal trocar-related hernias in patients undergoing Roux-en-Y gastric bypass surgery (RYGB). We performed a retrospective review of our last 747 consecutive operative procedures using these trocars. Methods and procedures: The patient population was 747 consecutive patients who underwent laparoscopic RYGB at Duke University Health System Weight Loss Surgery Center from January 2002 through April 2005. A total of 3735 radially expanded trocar sites were used. VersaStep™ trocars were used in all cases. The port configuration included one supraumbilical Hasson port, two 12-mm ports, and three 5-mm ports. The Hasson port was closed with a figure-of-eight number 1 Polysorb suture. All other trocar sites had no fascial closure. Intestinal anastomoses were created with a linear stapler in all of the laparoscopic cases, with hand suturing of the residual enterotomy. The fascial incisions were therefore not extended to accommodate an EEA stapler. The charts were reviewed for occurrence of subsequent trocar site hernias. Results: There were no hernias at any of the VersaStep™ trocar sites-an incidence of 0%. There were nine incisional hernias at the Hasson port site which later required surgical repair-an incidence of 1.20%. Conclusions: There were no hernias detected at any of the 1494 12-mm or 2241 5-mm VersaStep™ trocar sites, despite lack of suture closure. At the Hasson port site, there was a hernia incidence of 1.20%. In the bariatric RYGB population, routine suture closure of the fascia or muscle is not necessary when using radially expanding VersaStep™ trocars.

Original languageEnglish (US)
Pages (from-to)1584-1586
Number of pages3
JournalSurgical Endoscopy and Other Interventional Techniques
Volume20
Issue number10
DOIs
StatePublished - Oct 2006
Externally publishedYes

Fingerprint

Bariatrics
Hernia
Surgical Instruments
Gastric Bypass
Sutures
Incidence
Fascia
Operative Surgical Procedures
Population
Weight Loss
Hand

Keywords

  • Bariatric
  • Trocar hernia

ASJC Scopus subject areas

  • Surgery

Cite this

VersaStep™ trocar hernia rate in unclosed fascial defects in bariatric patients. / Johnson, W. H.; Fecher, A. M.; McMahon, R. L.; Grant, J. P.; Pryor, A. D.

In: Surgical Endoscopy and Other Interventional Techniques, Vol. 20, No. 10, 10.2006, p. 1584-1586.

Research output: Contribution to journalArticle

Johnson, W. H. ; Fecher, A. M. ; McMahon, R. L. ; Grant, J. P. ; Pryor, A. D. / VersaStep™ trocar hernia rate in unclosed fascial defects in bariatric patients. In: Surgical Endoscopy and Other Interventional Techniques. 2006 ; Vol. 20, No. 10. pp. 1584-1586.
@article{a9984ab6325b481e9545c36e07120a21,
title = "VersaStep™ trocar hernia rate in unclosed fascial defects in bariatric patients",
abstract = "Objective: Use of the VersaStep™ trocar system (US Surgical, Norwalk, CT) has the perceived advantage of minimal trocar-related hernias in patients undergoing Roux-en-Y gastric bypass surgery (RYGB). We performed a retrospective review of our last 747 consecutive operative procedures using these trocars. Methods and procedures: The patient population was 747 consecutive patients who underwent laparoscopic RYGB at Duke University Health System Weight Loss Surgery Center from January 2002 through April 2005. A total of 3735 radially expanded trocar sites were used. VersaStep™ trocars were used in all cases. The port configuration included one supraumbilical Hasson port, two 12-mm ports, and three 5-mm ports. The Hasson port was closed with a figure-of-eight number 1 Polysorb suture. All other trocar sites had no fascial closure. Intestinal anastomoses were created with a linear stapler in all of the laparoscopic cases, with hand suturing of the residual enterotomy. The fascial incisions were therefore not extended to accommodate an EEA stapler. The charts were reviewed for occurrence of subsequent trocar site hernias. Results: There were no hernias at any of the VersaStep™ trocar sites-an incidence of 0{\%}. There were nine incisional hernias at the Hasson port site which later required surgical repair-an incidence of 1.20{\%}. Conclusions: There were no hernias detected at any of the 1494 12-mm or 2241 5-mm VersaStep™ trocar sites, despite lack of suture closure. At the Hasson port site, there was a hernia incidence of 1.20{\%}. In the bariatric RYGB population, routine suture closure of the fascia or muscle is not necessary when using radially expanding VersaStep™ trocars.",
keywords = "Bariatric, Trocar hernia",
author = "Johnson, {W. H.} and Fecher, {A. M.} and McMahon, {R. L.} and Grant, {J. P.} and Pryor, {A. D.}",
year = "2006",
month = "10",
doi = "10.1007/s00464-005-0747-8",
language = "English (US)",
volume = "20",
pages = "1584--1586",
journal = "Surgical Endoscopy",
issn = "0930-2794",
publisher = "Springer New York",
number = "10",

}

TY - JOUR

T1 - VersaStep™ trocar hernia rate in unclosed fascial defects in bariatric patients

AU - Johnson, W. H.

AU - Fecher, A. M.

AU - McMahon, R. L.

AU - Grant, J. P.

AU - Pryor, A. D.

PY - 2006/10

Y1 - 2006/10

N2 - Objective: Use of the VersaStep™ trocar system (US Surgical, Norwalk, CT) has the perceived advantage of minimal trocar-related hernias in patients undergoing Roux-en-Y gastric bypass surgery (RYGB). We performed a retrospective review of our last 747 consecutive operative procedures using these trocars. Methods and procedures: The patient population was 747 consecutive patients who underwent laparoscopic RYGB at Duke University Health System Weight Loss Surgery Center from January 2002 through April 2005. A total of 3735 radially expanded trocar sites were used. VersaStep™ trocars were used in all cases. The port configuration included one supraumbilical Hasson port, two 12-mm ports, and three 5-mm ports. The Hasson port was closed with a figure-of-eight number 1 Polysorb suture. All other trocar sites had no fascial closure. Intestinal anastomoses were created with a linear stapler in all of the laparoscopic cases, with hand suturing of the residual enterotomy. The fascial incisions were therefore not extended to accommodate an EEA stapler. The charts were reviewed for occurrence of subsequent trocar site hernias. Results: There were no hernias at any of the VersaStep™ trocar sites-an incidence of 0%. There were nine incisional hernias at the Hasson port site which later required surgical repair-an incidence of 1.20%. Conclusions: There were no hernias detected at any of the 1494 12-mm or 2241 5-mm VersaStep™ trocar sites, despite lack of suture closure. At the Hasson port site, there was a hernia incidence of 1.20%. In the bariatric RYGB population, routine suture closure of the fascia or muscle is not necessary when using radially expanding VersaStep™ trocars.

AB - Objective: Use of the VersaStep™ trocar system (US Surgical, Norwalk, CT) has the perceived advantage of minimal trocar-related hernias in patients undergoing Roux-en-Y gastric bypass surgery (RYGB). We performed a retrospective review of our last 747 consecutive operative procedures using these trocars. Methods and procedures: The patient population was 747 consecutive patients who underwent laparoscopic RYGB at Duke University Health System Weight Loss Surgery Center from January 2002 through April 2005. A total of 3735 radially expanded trocar sites were used. VersaStep™ trocars were used in all cases. The port configuration included one supraumbilical Hasson port, two 12-mm ports, and three 5-mm ports. The Hasson port was closed with a figure-of-eight number 1 Polysorb suture. All other trocar sites had no fascial closure. Intestinal anastomoses were created with a linear stapler in all of the laparoscopic cases, with hand suturing of the residual enterotomy. The fascial incisions were therefore not extended to accommodate an EEA stapler. The charts were reviewed for occurrence of subsequent trocar site hernias. Results: There were no hernias at any of the VersaStep™ trocar sites-an incidence of 0%. There were nine incisional hernias at the Hasson port site which later required surgical repair-an incidence of 1.20%. Conclusions: There were no hernias detected at any of the 1494 12-mm or 2241 5-mm VersaStep™ trocar sites, despite lack of suture closure. At the Hasson port site, there was a hernia incidence of 1.20%. In the bariatric RYGB population, routine suture closure of the fascia or muscle is not necessary when using radially expanding VersaStep™ trocars.

KW - Bariatric

KW - Trocar hernia

UR - http://www.scopus.com/inward/record.url?scp=33748990340&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33748990340&partnerID=8YFLogxK

U2 - 10.1007/s00464-005-0747-8

DO - 10.1007/s00464-005-0747-8

M3 - Article

VL - 20

SP - 1584

EP - 1586

JO - Surgical Endoscopy

JF - Surgical Endoscopy

SN - 0930-2794

IS - 10

ER -