Volume-associated ambulatory blood pressure patterns in hemodialysis patients

Research output: Contribution to journalArticle

36 Citations (Scopus)

Abstract

Although volume excess causes hypertension, whether it also affects circadian patterns of arterial pressures among hemodialysis patients remains unknown. To test the notion of whether volume overload is associated with a unique blood pressure (BP) "signature," a posthoc analysis was performed among 145 patients participating in the Dry-Weight Reduction in Hypertensive Hemodialysis Patients randomized, controlled trial. Using 400 ambulatory BP recordings over 8 weeks composed of 35 302 measurements, the trended cosinor model was found to be the best descriptor of BP chronobiology. The trended cosinor model may be described as a pattern of sinusoidal oscillation around a straight line with an upward trend during the interdialytic period that has an intercept at the postdialysis time. Augmented volume removal therapy reduced the intercept systolic BP and increased the rate of rise in systolic BP over the interdialytic interval but had no effect on the systolic BP fluctuation (amplitude). Thus, an elevated intercept and blunted slope pattern characterize the "volume-overload BP pattern" on ambulatory BP monitoring. Similar changes were seen for diastolic BP. Augmented volume removal therapy neither restored dipping nor was associated with a lag phenomenon for either the wake or the sleep systolic BP. Lowering of systolic BP was greater than diastolic BP such that pulse pressure was reduced. An observational cohort of 37 patients followed for 6 months confirmed these findings. Randomized trials are now needed to evaluate the clinical impact of augmented volume removal therapy on hard outcomes, because reduction of pulse pressure with this simple expedient has the potential to improve survival in hemodialysis patients.

Original languageEnglish (US)
Pages (from-to)241-247
Number of pages7
JournalHypertension
Volume54
Issue number2
DOIs
StatePublished - Aug 2009
Externally publishedYes

Fingerprint

Renal Dialysis
Blood Pressure
Ambulatory Blood Pressure Monitoring

Keywords

  • Ambulatory blood pressure monitoring
  • Blood volume
  • Chronobiology phenomena
  • Hemodialysis
  • Hypertension

ASJC Scopus subject areas

  • Internal Medicine

Cite this

Volume-associated ambulatory blood pressure patterns in hemodialysis patients. / Agarwal, Rajiv.

In: Hypertension, Vol. 54, No. 2, 08.2009, p. 241-247.

Research output: Contribution to journalArticle

@article{11c3a608f6a9464ab50b6d26514d12d2,
title = "Volume-associated ambulatory blood pressure patterns in hemodialysis patients",
abstract = "Although volume excess causes hypertension, whether it also affects circadian patterns of arterial pressures among hemodialysis patients remains unknown. To test the notion of whether volume overload is associated with a unique blood pressure (BP) {"}signature,{"} a posthoc analysis was performed among 145 patients participating in the Dry-Weight Reduction in Hypertensive Hemodialysis Patients randomized, controlled trial. Using 400 ambulatory BP recordings over 8 weeks composed of 35 302 measurements, the trended cosinor model was found to be the best descriptor of BP chronobiology. The trended cosinor model may be described as a pattern of sinusoidal oscillation around a straight line with an upward trend during the interdialytic period that has an intercept at the postdialysis time. Augmented volume removal therapy reduced the intercept systolic BP and increased the rate of rise in systolic BP over the interdialytic interval but had no effect on the systolic BP fluctuation (amplitude). Thus, an elevated intercept and blunted slope pattern characterize the {"}volume-overload BP pattern{"} on ambulatory BP monitoring. Similar changes were seen for diastolic BP. Augmented volume removal therapy neither restored dipping nor was associated with a lag phenomenon for either the wake or the sleep systolic BP. Lowering of systolic BP was greater than diastolic BP such that pulse pressure was reduced. An observational cohort of 37 patients followed for 6 months confirmed these findings. Randomized trials are now needed to evaluate the clinical impact of augmented volume removal therapy on hard outcomes, because reduction of pulse pressure with this simple expedient has the potential to improve survival in hemodialysis patients.",
keywords = "Ambulatory blood pressure monitoring, Blood volume, Chronobiology phenomena, Hemodialysis, Hypertension",
author = "Rajiv Agarwal",
year = "2009",
month = "8",
doi = "10.1161/HYPERTENSIONAHA.109.136366",
language = "English (US)",
volume = "54",
pages = "241--247",
journal = "Hypertension",
issn = "0194-911X",
publisher = "Lippincott Williams and Wilkins",
number = "2",

}

TY - JOUR

T1 - Volume-associated ambulatory blood pressure patterns in hemodialysis patients

AU - Agarwal, Rajiv

PY - 2009/8

Y1 - 2009/8

N2 - Although volume excess causes hypertension, whether it also affects circadian patterns of arterial pressures among hemodialysis patients remains unknown. To test the notion of whether volume overload is associated with a unique blood pressure (BP) "signature," a posthoc analysis was performed among 145 patients participating in the Dry-Weight Reduction in Hypertensive Hemodialysis Patients randomized, controlled trial. Using 400 ambulatory BP recordings over 8 weeks composed of 35 302 measurements, the trended cosinor model was found to be the best descriptor of BP chronobiology. The trended cosinor model may be described as a pattern of sinusoidal oscillation around a straight line with an upward trend during the interdialytic period that has an intercept at the postdialysis time. Augmented volume removal therapy reduced the intercept systolic BP and increased the rate of rise in systolic BP over the interdialytic interval but had no effect on the systolic BP fluctuation (amplitude). Thus, an elevated intercept and blunted slope pattern characterize the "volume-overload BP pattern" on ambulatory BP monitoring. Similar changes were seen for diastolic BP. Augmented volume removal therapy neither restored dipping nor was associated with a lag phenomenon for either the wake or the sleep systolic BP. Lowering of systolic BP was greater than diastolic BP such that pulse pressure was reduced. An observational cohort of 37 patients followed for 6 months confirmed these findings. Randomized trials are now needed to evaluate the clinical impact of augmented volume removal therapy on hard outcomes, because reduction of pulse pressure with this simple expedient has the potential to improve survival in hemodialysis patients.

AB - Although volume excess causes hypertension, whether it also affects circadian patterns of arterial pressures among hemodialysis patients remains unknown. To test the notion of whether volume overload is associated with a unique blood pressure (BP) "signature," a posthoc analysis was performed among 145 patients participating in the Dry-Weight Reduction in Hypertensive Hemodialysis Patients randomized, controlled trial. Using 400 ambulatory BP recordings over 8 weeks composed of 35 302 measurements, the trended cosinor model was found to be the best descriptor of BP chronobiology. The trended cosinor model may be described as a pattern of sinusoidal oscillation around a straight line with an upward trend during the interdialytic period that has an intercept at the postdialysis time. Augmented volume removal therapy reduced the intercept systolic BP and increased the rate of rise in systolic BP over the interdialytic interval but had no effect on the systolic BP fluctuation (amplitude). Thus, an elevated intercept and blunted slope pattern characterize the "volume-overload BP pattern" on ambulatory BP monitoring. Similar changes were seen for diastolic BP. Augmented volume removal therapy neither restored dipping nor was associated with a lag phenomenon for either the wake or the sleep systolic BP. Lowering of systolic BP was greater than diastolic BP such that pulse pressure was reduced. An observational cohort of 37 patients followed for 6 months confirmed these findings. Randomized trials are now needed to evaluate the clinical impact of augmented volume removal therapy on hard outcomes, because reduction of pulse pressure with this simple expedient has the potential to improve survival in hemodialysis patients.

KW - Ambulatory blood pressure monitoring

KW - Blood volume

KW - Chronobiology phenomena

KW - Hemodialysis

KW - Hypertension

UR - http://www.scopus.com/inward/record.url?scp=68549140186&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=68549140186&partnerID=8YFLogxK

U2 - 10.1161/HYPERTENSIONAHA.109.136366

DO - 10.1161/HYPERTENSIONAHA.109.136366

M3 - Article

C2 - 19528362

AN - SCOPUS:68549140186

VL - 54

SP - 241

EP - 247

JO - Hypertension

JF - Hypertension

SN - 0194-911X

IS - 2

ER -